Key Specifications
GTIN:4046356462198
Note:Made to Order (non-returnable)
Orderkey:2804694
(General):Ex iaD 20 T85 °C...T135 °C
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356462198
NoteMade to Order (non-returnable)
Orderkey2804694
(General)Ex iaD 20 T85 °C...T135 °C
Catalog pagePage 92 (C-6-2013)
Packing unit10 pc
ATEX (General) II 1 G Ex ia IIC T4...T6
IECEx (General)Ga Ex ia IIC T4...T6
Country of originDE (Germany)
Capacity (General)≤ 1.5 nF (per path)
Custom tariff number85363010
Altitude (Dimensions)≤ 2000 m (amsl (above mean sea level))
Rated current (General)500 mA (40 °C)
(Conformity / approvals)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Type (Ambient conditions)DIN rail module, one-piece
Color (Ambient conditions)anthracite grey RAL 7016
Depth (Key Commercial Data)102.5 mm (incl. DIN rail 7.5 mm)
Width (Key Commercial Data)6.2 mm
(Standards and Regulations)500 mA (T6 / ≤ 40 °C)
Height (Key Commercial Data)93.1 mm
Nominal voltage UN (General)12 V DC
Residual current IPE (General)≤ 2 µA
Resistance in series (General)0 Ω
Degree of protection (Dimensions)IP20
IEC test classification (General)C1
Screw thread (Protective circuit)M3
Mounting type (Ambient conditions)DIN rail: 35 mm
China RoHS (Conformity / approvals)Environmentally Friendly Use Period = 50
Connection method (Connection data)DIN rail NS35
(Connection, equipotential bonding)IEC 60079-26 2006
Input attenuation aE, sym. (General)typ. 0.3 dB (1.5 MHz/50 Ω)
Max. required back-up fuse (General)500 mA (T)
Weight per Piece (excluding packing)55.750 g
Housing material (Ambient conditions)PBT
Response time tA(line-line) (General)≤ 1 ns
Stripping length (Protective circuit)8 mm
Connection method (Protective circuit)Screw connection
Response time tA(line-earth) (General)≤ 100 ns
Tightening torque (Protective circuit)0.8 Nm
Maximum continuous voltage UC (General)18 V DC
Direction of action (Ambient conditions)Line-Line & Line-Earth Ground
Impulse durability (line-line) (General)C1 - 500 V / 250 A
Surge protection fault message (General)none
Impulse durability (line-earth) (General)C1 - 500 V / 250 A
Residual voltage at In(line-line) (General)≤ 50 V
Ambient temperature (operation) (Dimensions)-40 °C ... 80 °C
Operating effective current ICat UC (General)≤ 2 µA
max. input power Pi (Standards and Regulations)635 mW
Conductor cross section AWG (Protective circuit)24 ... 14
Voltage protection level Up(line-line) (General)≤ 50 V (C1 - 500 V / 250 A)
Max. input current Ii (Standards and Regulations)500 mA (T4 / ≤ 80°C)
Max. input voltage Ui (Standards and Regulations)18 V DC
Voltage protection level Up(line-earth) (General)≤ 650 V (C1 - 500 V / 250 A)
Conductor cross section solid (Protective circuit)0.2 mm² ... 2.5 mm²
Total discharge current Itotal(8/20) µs (General)10 kA
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 80 °C
Conductor cross section flexible (Protective circuit)0.2 mm² ... 2.5 mm²
Max. internal inductance Li (Standards and Regulations)< 1 µH
Maximum inner capacitance Ci (Standards and Regulations)typ. 3 nF
Flammability rating according to UL 94 (Ambient conditions)V-0
Alternating current carrying capacity (line-earth) (General)5 A - 1 s
Cut-off frequency fg (3 dB), sym. in 50 Ohm system (General)typ. 5 MHz
Nominal discharge current In(8/20) µs (line-line) (General)350 A
Standards/specifications (Connection, equipotential bonding)EN 61643-21 A2:2013
Cut-off frequency fg (3 dB), sym. in 150 Ohm system (General)typ. 1.7 MHz
Maximum inner time factor (Ri/Li) (Standards and Regulations)10 µs
Nominal discharge current In(8/20) µs (line-earth) (General)5 kA
Nominal pulse current Ian (10/1000) µs (line-line) (General)70 A
Residual voltage with Ian (10/1000) µs (line-line) (General)≤ 50 V
Nominal pulse current Ian (10/1000) µs (line-earth) (General)50 A
Pulse discharge current Iimp(10/350) µs (line-earth) (General)500 A
Output voltage limitation at 1 kV/µs (line-line) spike (General)≤ 50 V
Output voltage limitation at 1 kV/µs (line-earth) spike (General)≤ 650 V
Max. discharge current Imax(8/20) µs maximum (line-line) (General)350 A
Max. discharge current Imax(8/20) µs maximum (line-earth) (General)10 kA

Product Description

Surge protection on the module for one-piece symmetrical rail mounting, 6.2 mm wide, for two potential-free signal conductors. Tested according to the degrees of protection in the Ex zones: Ex ia IIC
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top