Service time: Monday to Friday 9:00-18:00
FLT-SEC-T1+T2-2IT-350/25-FM - FLT-SEC-T1+T2-2IT-350/25-FM 1044388 PHOENIX CONTACT Type 1+2 protective device combination
In Stock Hot Product

FLT-SEC-T1+T2-2IT-350/25-FM

FLT-SEC-T1+T2-2IT-350/25-FM 1044388 PHOENIX CONTACT Type 1+2 protective device combination

$0.00USD
4035 in stock
Key Specifications
GTIN:4055626620862
Note:Made to Order (non-returnable)
Orderkey:1044388
Packing unit:1 pc
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626620862
NoteMade to Order (non-returnable)
Orderkey1044388
Packing unit1 pc
Country of originDE (Germany)
(Connection data)EN 61643-11 2012
Custom tariff number85363030
(Ambient conditions)PBT-FR
(Protective circuit)1 A DC (30 V DC)
Altitude (Dimensions)≤ 2000 m (amsl (above mean sea level))
Type (Ambient conditions)DIN rail module, two-section, divisible
(Additional descriptions)≤ 0.9 kV (at 3 kA / L2-PE)
Color (Ambient conditions)light gray RAL 7035
Depth (Key Commercial Data)74.5 mm
Width (Key Commercial Data)71.2 mm
EN type (Ambient conditions)T1 + T2
Height (Key Commercial Data)95.2 mm
Shock (operation) (Dimensions)25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Degree of protection (Dimensions)IP20 (only when all terminal points are used)
Screw thread (Protective circuit)M2
Mounting type (Ambient conditions)DIN rail: 35 mm
Vibration (operation) (Dimensions)5g (5 - 500 Hz/2.5 h/X, Y, Z)
Weight per Piece (excluding packing)633.600 g
Housing material (Ambient conditions)PA 6.6-FR 20% GF
Stripping length (Protective circuit)7 mm
Connection method (Protective circuit)Plug-in/screw connection via COMBICON
Horizontal pitch (Key Commercial Data)4 Div.
Operating current (Protective circuit)10 mA AC ... 1 A AC
Operating voltage (Protective circuit)12 V AC ... 250 V AC
REACh SVHC (Standards and Regulations)Lead 7439-92-1
Tightening torque (Protective circuit)0.25 Nm
Mode of protection (Ambient conditions)L-PE
Standards/regulations (Connection data)IEC 61643-11 2011
Switching function (Protective circuit)PDT contact
Degree of pollution (Ambient conditions)2
Screw thread (Indicator/remote signaling)M5
Response time tA (Additional descriptions)≤ 25 ns
Ambient temperature (operation) (Dimensions)-40 °C ... 80 °C
IEC power supply system (Ambient conditions)IT
IEC test classification (Ambient conditions)I + II
Nominal voltage UN (Additional descriptions)240 V AC (IT)
Permissible humidity (operation) (Dimensions)5 % ... 95 %
Stripping length (Indicator/remote signaling)18 mm
Connection method (Indicator/remote signaling)Fork-type cable lug
Nominal frequency fN (Additional descriptions)50 Hz (60 Hz)
Residual current IPE (Additional descriptions)≤ 0.5 mA
Tightening torque (Indicator/remote signaling)4.5 Nm
Rated load current IL (Additional descriptions)125 A (< 55 °C)
Conductor cross section AWG (Protective circuit)28 ... 16
Conductor cross section solid (Protective circuit)0.14 mm² ... 1.5 mm²
TOV behavior at UT(L-PE) (Additional descriptions)415 V AC (5 s / withstand mode)
Surge protection fault message (Ambient conditions)Optical, remote indicator contact
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 80 °C
Residual voltage Ures(L-L) (Additional descriptions)≤ 1.5 kV (at In/ L1-L2)
Conductor cross section flexible (Protective circuit)0.14 mm² ... 1.5 mm²
Residual voltage Ures(L-PE) (Additional descriptions)≤ 2.8 kV (at In/ L1-PE)
Conductor cross section AWG (Indicator/remote signaling)13 ... 2
Conductor cross section solid (Indicator/remote signaling)2.5 mm² ... 35 mm²
Voltage protection level Up(L-L) (Additional descriptions)≤ 1.5 kV (L1-L2)
Flammability rating according to UL 94 (Ambient conditions)V-0
Voltage protection level Up(L-PE) (Additional descriptions)≤ 2.8 kV (L1-PE)
Short-circuit current rating ISCCR (Additional descriptions)25 kA (264 V AC)
Conductor cross section flexible (Indicator/remote signaling)1.5 mm² ... 16 mm²
Max. backup fuse with branch wiring (Additional descriptions)315 A (gG)
Nominal discharge current In(8/20) µs (Additional descriptions)25 kA
Follow current interrupt rating Ifi(L-PE) (Additional descriptions)25 kA (264 V AC)
Max. backup fuse with V-type through wiring (Additional descriptions)125 A (gG)
Maximum continuous operating voltage UC(L-PE) (Additional descriptions)350 V AC
Impulse discharge current (10/350) µs, charge (Additional descriptions)12.5 As
Impulse discharge current (10/350) µs, peak value limp (Additional descriptions)25 kA
Impulse discharge current (10/350) µs, specific energy (Additional descriptions)160 kJ/Ω

Product Description

Combination of pluggable lightning and surge arresters, according to type 1+2/class I+II, for two-phase power supply networks with isolated operation (L1, L2, PE).
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top