Service time: Monday to Friday 9:00-18:00
FLT-CP-2C-350 - FLT-CP-2C-350 2859770 PHOENIX CONTACT Type 1+2 protective device combination
In Stock Hot Product

FLT-CP-2C-350

FLT-CP-2C-350 2859770 PHOENIX CONTACT Type 1+2 protective device combination

$0.00USD
3092 in stock
Key Specifications
:T1 + T2
Note:2011
Type:DIN rail module, two-section, divisible
Depth:71.5 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
T1 + T2
Note2011
TypeDIN rail module, two-section, divisible
Depth71.5 mm
Width71.2 mm
Height95 mm
Altitude≤ 2000 m (amsl)
SPD Type4CA
Product typeArrester combination
Screw threadM5
Mounting typeDIN rail: 35 mm
Material groupI
Connection nameRemote fault indicator contact
Nominal voltage240/415 V AC
Open side panelNo
Horizontal pitch4 Div.
Housing materialPBT
Pollution degree2
Response time tA≤ 25 ns
Stripping length18 mm
Connection methodScrew terminal blocks
Nominal frequency50/60 Hz
Operating current10 mA AC ... 1 A AC
Operating voltage12 V AC ... 250 V AC
Shock (operation)25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Tightening torque4.5 Nm
Mode of protectionL-PEN
Nominal voltage UN240/415 V AC (TN-C)
Switching functionChangeover contact
TOV behavior at UT415 V AC (5 s / withstand mode)
Dimensional drawing
Direction of action2L-N/PE
Insulating materialPA 6.6/PBT
Number of positions2
AC operating current1 A AC
Degree of protectionIP20 (only when all terminal points are used)
Follow current (N-G)10 kA (264 V AC)
Nominal frequency fN50 Hz (60 Hz)
Overvoltage categoryIII
CTI value of material600
Rated load current IL125 A (< 55 °C)
Residual voltage Ures≤ 1.5 kV (at In)
Standards/regulationsDIN VDE 0110-1 / IEC 60664-1 / IEC 61643-1
Vibration (operation)5g (5 - 500 Hz/2.5 h/X, Y, Z)
IEC power supply systemTN-C
IEC test classificationI + II
Standards/specificationsIEC 61643-11
Power distribution systemDelta
Conductor cross section AWG13 ... 2
Voltage protection level Up≤ 1.5 kV
Conductor cross section rigid2.5 mm² ... 35 mm²
Maximum continuous voltage UC350 V AC
Surge protection fault messageOptical, remote indicator contact
Ambient temperature (operation)-40 °C ... 80 °C
Conductor cross section flexible2.5 mm² ... 25 mm²
Permissible humidity (operation)5 % ... 95 %
Nominal discharge current In(L-G)20 kA
Nominal discharge current In(L-L)20 kA
Short-circuit current rating ISCCR25 kA (264 V AC)
Follow current interrupt rating Ifi25 kA (264 V AC)
Max. backup fuse with branch wiring315 A (gG)
Measured limiting voltage MLV (L-G)1340 V
Measured limiting voltage MLV (L-L)2450 V
Flammability rating according to UL 94V - 0
Nominal discharge current In(8/20) µs25 kA
Ambient temperature (storage/transport)-40 °C ... 80 °C
Max. backup fuse with V-type through wiring125 A (gG)
Impulse discharge current (10/350) µs, charge12.5 As
Maximum continuous operating voltage MCOV (L-G)264 V AC
Maximum continuous operating voltage MCOV (L-L)528 V AC
Front of wave sparkover voltage at 6 kV (1.2/50) µs≤ 1.5 kV
Impulse discharge current (10/350) µs, peak value limp25 kA
Impulse discharge current (10/350) µs, specific energy160 kJ/Ω

Product Description

Pluggable lightning current and surge arrester combination, in acc. with typ 1+2 / Class I+II / B+C arresters. Arresters coordinated following the AEC principle, for 2-phase power supply networks with
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top