Service time: Monday to Friday 9:00-18:00
F-MS 12 - F-MS 12 2817987 PHOENIX CONTACT Type 2 surge arrester
In Stock Hot Product

F-MS 12

F-MS 12 2817987 PHOENIX CONTACT Type 2 surge arrester

$0.00USD
4298 in stock
Key Specifications
GTIN:4017918163662
Orderkey:2817987
(General):≤ 0.1 kV (at 3 kA)
Catalog page:Page 55 (C-4-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4017918163662
Orderkey2817987
(General)≤ 0.1 kV (at 3 kA)
Catalog pagePage 55 (C-4-2017)
Packing unit1 pc
Country of originDE (Germany)
Custom tariff number85363030
(Ambient conditions)PBT
(Protective circuit)4.5 Nm (25 mm² ... 35 mm²)
(UL connection data)EN 61643-11 2012
Altitude (Dimensions)≤ 2000 m (amsl (above mean sea level))
Type (Ambient conditions)DIN rail module, two-section, divisible
Color (Ambient conditions)jet black RAL 9005
Response time tA (General)≤ 100 ns
SPD Type (Connection data)4CA
Depth (Key Commercial Data)65.7 mm (incl. DIN rail 7.5 mm)
Width (Key Commercial Data)17.6 mm
EN type (Ambient conditions)T2
Height (Key Commercial Data)89.8 mm
Nominal voltage UN (General)240/415 V AC (TN - only N-PE)
TOV behavior at UT (General)1200 V AC (200 ms / withstand mode)
Nominal frequency fN (General)50 Hz (60 Hz)
Residual current IPE (General)≤ 5 µA
Shock (operation) (Dimensions)25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Rated load current IL (General)80 A
Residual voltage Ures (General)≤ 0.4 kV (at In)
Degree of protection (Dimensions)IP20 (only when all terminal points are used)
Screw thread (Protective circuit)M5
Mounting type (Ambient conditions)DIN rail: 35 mm
Vibration (operation) (Dimensions)5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
Nominal frequency (Connection data)50/60 Hz
Mode of protection (Connection data)N-G
Weight per Piece (excluding packing)106.100 g
Housing material (Ambient conditions)PA 6.6
Stripping length (Protective circuit)16 mm
Tightening torque (UL specifications)30 lbf-in.
Voltage protection level Up (General)≤ 1.5 kV
Connection method (Protective circuit)Fork-type cable lug
Horizontal pitch (Key Commercial Data)1 Div.
Standby power consumption PC (General)≤ 1.5 mVA
Tightening torque (Protective circuit)3 Nm (1,5 mm² ... 16 mm²)
Maximum continuous voltage UC (General)260 V AC
Mode of protection (Ambient conditions)N-PE
Degree of pollution (Ambient conditions)2
Number of positions (Ambient conditions)1
Standards/regulations (UL connection data)IEC 61643-11 2011
Power distribution system (Connection data)Single phase
Ambient temperature (operation) (Dimensions)-40 °C ... 80 °C
IEC power supply system (Ambient conditions)TN
IEC test classification (Ambient conditions)II
Follow current interrupt rating Ifi (General)100 A
Permissible humidity (operation) (Dimensions)5 % ... 95 %
Conductor cross section AWG (UL specifications)10 ... 2
Conductor cross section AWG (Protective circuit)15 ... 2
Nominal discharge current In(8/20) µs (General)20 kA
Conductor cross section solid (Protective circuit)1.5 mm² ... 35 mm²
Maximum discharge current Imax(8/20) µs (General)40 kA
Nominal discharge current In(N-G) (Connection data)20 kA
Surge protection fault message (Ambient conditions)optical
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 80 °C
Conductor cross section flexible (Protective circuit)1.5 mm² ... 16 mm²
Max. backup fuse with V-type through wiring (General)80 A (gG)
Measured limiting voltage MLV (N-G) (Connection data)1490 V
Flammability rating according to UL 94 (Ambient conditions)V-0
Front of wave sparkover voltage at 6 kV (1.2/50) µs (General)≤ 1.5 kV
Maximum continuous operating voltage MCOV (N-G) (Connection data)260 V AC

Product Description

Type 2 surge arrester, consisting of base element and plug-in protection with N-PE sum current arc arrester, for mounting on NS 35/7.5, housing width: 17.5 mm (1 pc)
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top