Service time: Monday to Friday 9:00-18:00
DT-UFB-IB-RB0 - DT-UFB-IB-RB0 2800056 PHOENIX CONTACT Surge protection device
In Stock Hot Product

DT-UFB-IB-RB0

DT-UFB-IB-RB0 2800056 PHOENIX CONTACT Surge protection device

$0.00USD
4125 in stock
Key Specifications
GTIN:4046356462723
Note:Made to Order (non-returnable)
Orderkey:2800056
(General):D1 - 1 kA
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356462723
NoteMade to Order (non-returnable)
Orderkey2800056
(General)D1 - 1 kA
Catalog pagePage 159 (C-4-2017)
Packing unit1 pc
Country of originDE (Germany)
Custom tariff number85363010
(Ambient conditions)VDE 0110-1
Rated current (General)≤ 180 mA (25 °C)
Type (Ambient conditions)Attachment plug for DIN rail mounting
Color (Ambient conditions)silver/black
Depth (Key Commercial Data)63 mm
Width (Key Commercial Data)25 mm
Height (Key Commercial Data)110 mm
Capacity (line-line) (General)typ. 20 pF
Residual current IPE (General)≤ 5 µA
Resistance in series (General)typ. 7 Ω
VDE requirement class (General)B2
Degree of protection (Dimensions)IP20
IEC test classification (General)B2
Mounting type (Ambient conditions)Connection-specific attachment plug and DIN rail, 35 mm
Connection method (Connection data)Cable connection
(Connection, equipotential bonding)IEC 61643-21 2000
Input attenuation aE, sym. (General)typ. 0.5 dB (≤ 5 MHz / 150 Ω)
Weight per Piece (excluding packing)436.000 g
Housing material (Ambient conditions)Zinc die-cast
Response time tA(line-line) (General)≤ 1 ns
Connection method (Protective circuit)D-SUB-9
Response time tA(line-earth) (General)≤ 100 ns
Maximum continuous voltage UC (General)5.8 V DC
Direction of action (Ambient conditions)Line-Line & Line-Ground/Shield
Impulse durability (line-line) (General)C1 - 1 kV/500 A
Number of positions (Ambient conditions)5
Surge protection fault message (General)none
Connection method IN (Protective circuit)D-SUB-9 socket
Impulse durability (line-earth) (General)B2 - 4 kV/100 A
Connection method OUT (Protective circuit)D-SUB-9 connector
Connection technology (Protective circuit)Remote bus output
Residual voltage at In(line-line) (General)≤ 25 V
Ambient temperature (operation) (Dimensions)-40 °C ... 85 °C
Residual voltage at In(line-earth) (General)≤ 55 V
Operating effective current ICat UC (General)≤ 1 µA
Voltage protection level Up(line-line) (General)≤ 16 V (B2 - 100 A)
Voltage protection level Up(line-earth) (General)≤ 700 V (B2 - 100 A)
Total discharge current Itotal(8/20) µs (General)10 kA
Residual voltage at In(line-signalground) (General)≤ 25 V
Standards/regulations (Connection, equipotential bonding)IEC 61643-21
Nominal discharge current In(8/20) µs (line-line) (General)≤ 5 kA
Standards/specifications (Connection, equipotential bonding)DIN EN 61643-21 2002
Cut-off frequency fg (3 dB), sym. in 100 Ohm system (General)≥ 100 MHz
Cut-off frequency fg (3 dB), sym. in 150 Ohm system (General)≥ 100 MHz
Nominal discharge current In(8/20) µs (line-earth) (General)≤ 5 kA
Output voltage limitation at 1 kV/µs (line-earth) spike (General)≤ 700 V
Output voltage limitation at 1 kV/µs (line-line) static (General)≤ 15 V
Output voltage limitation at 1 kV/µs (line-earth) static (General)≤ 700 V
Standards for cearances and creepage distances (Ambient conditions)IEC 60664-1
Output voltage limitation at 1 kV/µs (line-signalground) static (General)≤ 15 V

Product Description

Adapter with surge protection for 5-conductor remote bus input. Connection: D-SUB 9 female-male. Alternatively, it can be fitted on a rail. Incl. 1 m cable with D-SUB connection 9.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top