Key Specifications
GTIN:4017918962814
Note:Made to Order (non-returnable)
Orderkey:2880163
(General):≤ 180 V (C1 - 500 V / 250 A (J2 OFF))
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4017918962814
NoteMade to Order (non-returnable)
Orderkey2880163
(General)≤ 180 V (C1 - 500 V / 250 A (J2 OFF))
Catalog pagePage 143 (C-4-2017)
Packing unit1 pc
Country of originDE (Germany)
(Connection data)DIN EN 50173-1
Custom tariff number85363010
(Ambient conditions)IEC 60664-1
Rated current (General)1.5 A (25 °C)
Type (Ambient conditions)19" rack patch module
Color (Ambient conditions)beige
Depth (Key Commercial Data)160 mm
Width (Key Commercial Data)483 mm
Height (Key Commercial Data)44 mm
Capacity (line-line) (General)typ. 20 pF
Residual current IPE (General)≤ 1 mA (jumper 2 unplugged)
Capacity (line-earth) (General)typ. 1 pF
Degree of protection (Dimensions)IP20
Height unit (Key Commercial Data)1 U
IEC test classification (General)C1
Mounting type (Ambient conditions)19" rack
Input attenuation aE, sym. (General)typ. 1 dB (≤ 100 MHz)
Weight per Piece (excluding packing)3,119.580 g
Housing material (Ambient conditions)Sheet steel
Response time tA(line-line) (General)≤ 1 ns
Connection method (Protective circuit)RJ45
Response time tA(line-earth) (General)≤ 1 ns
Maximum continuous voltage UC (General)6 V DC (Core - core)
Standards/regulations (Connection data)IEC 61643-21
Degree of pollution (Ambient conditions)2
Direction of action (Ambient conditions)Line-Line & Line-Signal Ground/Shield & Signal Ground/Shield-Earth Ground
Impulse durability (line-line) (General)C1 - 500 V / 250 A
Near-end crosstalk attenuation (General)typ. 36 dB (100 Ω system / 100 MHz)
Number of positions (Ambient conditions)8
Response time tA (line-shield) (General)≤ 100 ns
Surge protection fault message (General)none
Connection method IN (Protective circuit)RJ45 socket
Impulse durability (line-earth) (General)C1 - 500 V / 250 A
Overvoltage category (Ambient conditions)II
Connection method OUT (Protective circuit)RJ45 socket
Connection technology (Protective circuit)Network interfaces (e.g. Ethernet, Token Ring and CDDI/FDDI)
Standards/specifications (Connection data)IEC 61643-21 2000
Impulse durability (shield-earth) (General)C2 (4 kV / 2 kA)
Residual voltage at In(line-line) (General)≤ 65 V
Ambient temperature (operation) (Dimensions)-40 °C ... 80 °C
Residual voltage at In(line-earth) (General)≤ 45 V (J2 ON)
Operating effective current ICat UC (General)≤ 1 mA
Residual voltage at In(shield-earth) (General)≤ 700 V
Voltage protection level Up(line-line) (General)≤ 50 V (C1 - 500 V / 250 A)
Voltage protection level Up(line-earth) (General)≤ 40 V (C1 - 500 V / 250 A (J2 ON))
Total discharge current Itotal(8/20) µs (General)10 kA
Maximum continuous voltage UC(line-earth) (General)68 V DC (optional: +/- 6 V DC)
Voltage protection level Up(shield-ground) (General)≤ 800 V (with insulated housing)
Nominal discharge current In(8/20) µs (line-line) (General)350 A
Cut-off frequency fg (3 dB), sym. in 100 Ohm system (General)> 100 MHz
Nominal discharge current In(8/20) µs (line-earth) (General)350 A
Nominal pulse current Ian (10/1000) µs (line-line) (General)100 A
Nominal pulse current Ian (10/1000) µs (line-earth) (General)100 A
Nominal discharge current In(8/20) µs (shield-earth) (General)2.5 kA (with insulated housing)
Output voltage limitation at 1 kV/µs (line-line) static (General)≤ 20 V
Output voltage limitation at 1 kV/µs (line-earth) static (General)≤ 30 V (J2 plugged)
Standards for cearances and creepage distances (Ambient conditions)DIN VDE 0110-1
Output voltage limitation at 1 kV/µs (shield-earth) static (General)≤ 700 V (with insulated shield)

Product Description

19" rack with 8 surge-protected ports for data interfaces in Ethernet networks (1000Base-T), Token ring, FDDI/CDDI according to Class D/EN 50173 (CAT5e), connection to the protection module: RJ45 fema
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top