| Parameter | Value |
|---|---|
| GTIN | 4017918106553 |
| Note | Made to Order (non-returnable) |
| Orderkey | 2830498 |
| (General) | 200 mA DC (F) |
| Catalog page | Page 105 (C-6-2013) |
| Packing unit | 1 pc |
| Country of origin | DE (Germany) |
| (Connection data) | EN 61643-21 2001 + A1:2009 + A2:2013 |
| Custom tariff number | 85363010 |
| (Ambient conditions) | IEC 60664 |
| Altitude (Dimensions) | ≤ 2000 mm (amsl (above mean sea level)) |
| Rated current (General) | 1.5 A AC (per path) |
| Frequency range (General) | 50 Hz ... 60 Hz |
| Type (Ambient conditions) | LSA-PLUS module |
| Color (Ambient conditions) | jet black RAL 9005 |
| Depth (Key Commercial Data) | 68.5 mm |
| Width (Key Commercial Data) | 111 mm |
| Fixed cable length (General) | 10 m |
| Height (Key Commercial Data) | 22 mm |
| Nominal voltage UN (General) | 250 V DC |
| Residual current IPE (General) | ≤ 1 µA |
| Capacity (line-earth) (General) | typ. 2 pF (10-PE) |
| Degree of protection (Dimensions) | IP20 |
| IEC test classification (General) | C1 |
| Mounting type (Ambient conditions) | On CT-TERMIBLOCK and LSA-PLUS disconnect strip |
| Max. required back-up fuse (General) | 1.5 A AC (gL) |
| Weight per Piece (excluding packing) | 112.400 g |
| Housing material (Ambient conditions) | PBT |
| Response time tA(line-line) (General) | ≤ 25 ns |
| Capacity (line-signalground) (General) | typ. 320 pF |
| Connection method (Protective circuit) | can be plugged into COMTRAB-TERMIBLOCK and LSA-PLUS disconnect and switching strips |
| Response time tA(line-earth) (General) | ≤ 100 ns |
| Maximum continuous voltage UC (General) | 275 V DC |
| Direction of action (Ambient conditions) | Line-Line & Line-Earth Ground |
| Surge protection fault message (General) | none |
| Connection method IN (Protective circuit) | COMTRAB plug-in system |
| Impulse durability (line-earth) (General) | C2 - 3 kV/1.5 kA |
| Connection method OUT (Protective circuit) | COMTRAB plug-in system |
| Standards/specifications (Connection data) | IEC 61643-21 2000 + corrigendum 2001 + A1:2008, modified + A2:2012 |
| Ambient temperature (operation) (Dimensions) | -40 °C ... 85 °C |
| Residual voltage at In(line-earth) (General) | ≤ 1.4 kV |
| Operating effective current ICat UC (General) | ≤ 1.5 mA AC (per path) |
| Response time tA (line-signalground) (General) | ≤ 25 ns |
| Impulse durability (line-signalground) (General) | C2 - 3 kV/1.5 kA |
| Impulse durability (signalground-earth) (General) | C2 - 10 kV/5 kA |
| Voltage protection level Up(line-earth) (General) | ≤ 1.4 kV (10-PE) |
| Total discharge current Itotal(8/20) µs (General) | 5 kA |
| Residual voltage at In(line-signalground) (General) | ≤ 1.1 kV |
| Voltage protection level Up(line-signalground) (General) | ≤ 1.1 kV |
| Flammability rating according to UL 94 (Ambient conditions) | V-0 |
| Nominal discharge current In(8/20) µs (line-earth) (General) | 1.5 kA |
| Standards for cearances and creepage distances (Ambient conditions) | VDE 0110-1 |
| Max. discharge current Imax(8/20) µs maximum (line-earth) (General) | 5 kA (10-PE) |
| Nominal discharge current In(8/20) µs (core-signal ground) (General) | 1.5 kA |
| Nominal discharge current In(8/20) µs (signalground-earth) (General) | 5 kA |
| Max. discharge current Imax(8/20) µs maximum (line-signalground) (General) | 3 kA |
| Arrester can be tested with CHECKMASTER from software version: (Ambient conditions) | From SW rev. 1.00 |
Technical specifications and performance data
Installation and operation guide