Service time: Monday to Friday 9:00-18:00
CT 10-9VA-230AC - CT 10-9VA-230AC 2830498 PHOENIX CONTACT Surge protection plug
In Stock Hot Product

CT 10-9VA-230AC

CT 10-9VA-230AC 2830498 PHOENIX CONTACT Surge protection plug

$0.00USD
4586 in stock
Key Specifications
GTIN:4017918106553
Note:Made to Order (non-returnable)
Orderkey:2830498
(General):200 mA DC (F)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4017918106553
NoteMade to Order (non-returnable)
Orderkey2830498
(General)200 mA DC (F)
Catalog pagePage 105 (C-6-2013)
Packing unit1 pc
Country of originDE (Germany)
(Connection data)EN 61643-21 2001 + A1:2009 + A2:2013
Custom tariff number85363010
(Ambient conditions)IEC 60664
Altitude (Dimensions)≤ 2000 mm (amsl (above mean sea level))
Rated current (General)1.5 A AC (per path)
Frequency range (General)50 Hz ... 60 Hz
Type (Ambient conditions)LSA-PLUS module
Color (Ambient conditions)jet black RAL 9005
Depth (Key Commercial Data)68.5 mm
Width (Key Commercial Data)111 mm
Fixed cable length (General)10 m
Height (Key Commercial Data)22 mm
Nominal voltage UN (General)250 V DC
Residual current IPE (General)≤ 1 µA
Capacity (line-earth) (General)typ. 2 pF (10-PE)
Degree of protection (Dimensions)IP20
IEC test classification (General)C1
Mounting type (Ambient conditions)On CT-TERMIBLOCK and LSA-PLUS disconnect strip
Max. required back-up fuse (General)1.5 A AC (gL)
Weight per Piece (excluding packing)112.400 g
Housing material (Ambient conditions)PBT
Response time tA(line-line) (General)≤ 25 ns
Capacity (line-signalground) (General)typ. 320 pF
Connection method (Protective circuit)can be plugged into COMTRAB-TERMIBLOCK and LSA-PLUS disconnect and switching strips
Response time tA(line-earth) (General)≤ 100 ns
Maximum continuous voltage UC (General)275 V DC
Direction of action (Ambient conditions)Line-Line & Line-Earth Ground
Surge protection fault message (General)none
Connection method IN (Protective circuit)COMTRAB plug-in system
Impulse durability (line-earth) (General)C2 - 3 kV/1.5 kA
Connection method OUT (Protective circuit)COMTRAB plug-in system
Standards/specifications (Connection data)IEC 61643-21 2000 + corrigendum 2001 + A1:2008, modified + A2:2012
Ambient temperature (operation) (Dimensions)-40 °C ... 85 °C
Residual voltage at In(line-earth) (General)≤ 1.4 kV
Operating effective current ICat UC (General)≤ 1.5 mA AC (per path)
Response time tA (line-signalground) (General)≤ 25 ns
Impulse durability (line-signalground) (General)C2 - 3 kV/1.5 kA
Impulse durability (signalground-earth) (General)C2 - 10 kV/5 kA
Voltage protection level Up(line-earth) (General)≤ 1.4 kV (10-PE)
Total discharge current Itotal(8/20) µs (General)5 kA
Residual voltage at In(line-signalground) (General)≤ 1.1 kV
Voltage protection level Up(line-signalground) (General)≤ 1.1 kV
Flammability rating according to UL 94 (Ambient conditions)V-0
Nominal discharge current In(8/20) µs (line-earth) (General)1.5 kA
Standards for cearances and creepage distances (Ambient conditions)VDE 0110-1
Max. discharge current Imax(8/20) µs maximum (line-earth) (General)5 kA (10-PE)
Nominal discharge current In(8/20) µs (core-signal ground) (General)1.5 kA
Nominal discharge current In(8/20) µs (signalground-earth) (General)5 kA
Max. discharge current Imax(8/20) µs maximum (line-signalground) (General)3 kA
Arrester can be tested with CHECKMASTER from software version: (Ambient conditions)From SW rev. 1.00

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top