| Parameter | Value |
|---|---|
| GTIN | 4017918148584 |
| Orderkey | 2817686 |
| (General) | D1 - 2.5 kA |
| Catalog page | Page 177 (C-4-2017) |
| Packing unit | 1 pc |
| (Dimensions) | IP20 |
| Country of origin | DE (Germany) |
| Custom tariff number | 85363010 |
| (Ambient conditions) | IEC 60664-1 |
| Rated current (General) | 5 A (25 °C) |
| Type (Ambient conditions) | Attachment plug |
| Color (Ambient conditions) | black |
| Depth (Key Commercial Data) | 25.4 mm |
| Width (Key Commercial Data) | 25.4 mm |
| Height (Key Commercial Data) | 83 mm |
| Residual current IPE (General) | ≤ 2 µA |
| VDE requirement class (General) | C2 |
| Degree of protection (Dimensions) | IP20 |
| IEC test classification (General) | C2 |
| Mounting type (Ambient conditions) | Connection-specific intermediate plugging |
| Connection method (Connection data) | PVC litz wire |
| Weight per Piece (excluding packing) | 117.260 g |
| Housing material (Ambient conditions) | Aluminum |
| Input attenuation aE, asym. (General) | 0.1 dB (≤ 100 MHz) |
| Connection method (Protective circuit) | N connector 50 Ω |
| Response time tA(line-earth) (General) | ≤ 100 ns |
| Maximum continuous voltage UC (General) | 180 V DC |
| Capacity asymmetrical (shield) (General) | 7 pF (typical) |
| Degree of pollution (Ambient conditions) | 2 |
| Direction of action (Ambient conditions) | Line-Shield/Earth Ground |
| Response time tA (line-shield) (General) | ≤ 100 ns |
| Surge protection fault message (General) | none |
| Connection method IN (Protective circuit) | N connector, female |
| Impulse durability (line-earth) (General) | C2 - 10 kV/5 kA |
| Overvoltage category (Ambient conditions) | II |
| Response time tA (shield-earth) (General) | ≤ 100 ns |
| Connection method OUT (Protective circuit) | N connector, female |
| Impulse durability (shield-earth) (General) | C2 - 10 kV / 5 kA |
| Ambient temperature (operation) (Dimensions) | -40 °C ... 80 °C |
| Residual voltage at In(line-earth) (General) | ≤ 160 V (1.5 m cable) |
| Operating effective current ICat UC (General) | ≤ 1 µA |
| Residual voltage at In(line-shield) (General) | ≤ 55 V |
| Residual voltage at In(shield-earth) (General) | ≤ 160 V (1.5 m cable) |
| Voltage protection level Up(line-earth) (General) | ≤ 500 V (C2 - 10 kV / 5 kA) |
| Total discharge current Itotal(8/20) µs (General) | 10 kA |
| Voltage protection level Up(line-shield) (General) | ≤ 700 V (C2 - 10 kV / 5 kA) |
| Maximum continuous voltage UC(line-earth) (General) | 180 V DC |
| Standing wave ratio SWR in a 50 Ω system (General) | ≤ 1.2 (200 MHz) |
| Voltage protection level Up(shield-ground) (General) | ≤ 500 V (C2 - 10 kV / 5 kA) |
| Standards/regulations (Connection, equipotential bonding) | IEC 61643-21 |
| Standards/specifications (Connection, equipotential bonding) | IEC 61643-21 2002 |
| Nominal discharge current In(8/20) µs (line-earth) (General) | 5 kA |
| Nominal discharge current In(8/20) µs (line-shield) (General) | 5 kA |
| Nominal pulse current Ian (10/1000) µs (line-earth) (General) | 100 A |
| Nominal discharge current In(8/20) µs (shield-earth) (General) | 5 kA |
| Permissible HF power Pmaxat VSWR = xx (50 ohm system) (General) | 300 W (at SWR = 1.1 in a 50 Ω system) |
| Output voltage limitation at 1 kV/µs (line-earth) spike (General) | ≤ 470 V |
| Output voltage limitation at 1 kV/µs (line-earth) static (General) | ≤ 470 V |
| Output voltage limitation at 1 kV/µs (line-shield) spike (General) | ≤ 590 V |
| Standards for cearances and creepage distances (Ambient conditions) | DIN VDE 0110-1 |
| Output voltage limitation at 1 kV/µs (shield-earth) spike (General) | ≤ 470 V |
| Output voltage limitation at 1 kV/µs (shield-earth) static (General) | ≤ 33 V |
| Cut-off frequency fg (3 dB), asym. (shield) in 50 Ohm system (General) | typ. 1 GHz |
Technical specifications and performance data
Installation and operation guide