Service time: Monday to Friday 9:00-18:00
CN-LAMBDA/4-5.9-BB - CN-LAMBDA/4-5.9-BB 2838490 PHOENIX CONTACT Surge protection device
In Stock Hot Product

CN-LAMBDA/4-5.9-BB

CN-LAMBDA/4-5.9-BB 2838490 PHOENIX CONTACT Surge protection device

$0.00USD
3573 in stock
Key Specifications
GTIN:4046356285629
Orderkey:2838490
(General):D1 - 2.5 kA
Catalog page:Page 179 (C-4-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356285629
Orderkey2838490
(General)D1 - 2.5 kA
Catalog pagePage 179 (C-4-2017)
Packing unit1 pc
Country of originUS (United States)
Custom tariff number85363010
Rated current (General)5 A (25 °C)
Frequency range (General)2.4 GHz ... 5.9 GHz
Type (Ambient conditions)Attachment plug
Color (Ambient conditions)nickel
Depth (Key Commercial Data)60 mm
Width (Key Commercial Data)26.1 mm
(Standards and Regulations)No hazardous substances above threshold values
Height (Key Commercial Data)38 mm
VDE requirement class (General)C2
Degree of protection (Dimensions)IP68
IEC test classification (General)C2
Mounting type (Ambient conditions)Connection-specific intermediate plugging
Weight per Piece (excluding packing)140.190 g
Housing material (Ambient conditions)Brass (CuZn)
Input attenuation aE, asym. (General)typ. 0.05 dB (≤ 0.15 dB)
China RoHS (Standards and Regulations)Environmentally friendly use period: unlimited = EFUP-e
Connection method (Protective circuit)N Connector
Standards/regulations (Connection data)IEC 61643-21
Direction of action (Ambient conditions)Line-Shield/Earth Ground
Number of positions (Ambient conditions)1
Surge protection fault message (General)none
Connection method IN (Protective circuit)N connector, female
Impulse durability (line-earth) (General)C2 - 10 kV/5 kA
Connection method OUT (Protective circuit)N connector, female
Impulse durability (line-shield) (General)C2 - 10 kV/5 kA
Standards/specifications (Connection data)IEC 61643-21 2005
Ambient temperature (operation) (Dimensions)-40 °C ... 90 °C
Voltage protection level Up(line-earth) (General)≤ 11 V (6 kV / 3 kA)
Total discharge current Itotal(8/20) µs (General)60 kA
Voltage protection level Up(line-shield) (General)≤ 11 V (6 kV / 3 kA)
Standing wave ratio SWR in a 50 Ω system (General)typ. 1.1 (≤ 1.20 (2.4 GHz...5.9 GHz))
Total discharge current Itotal(10/350) µs (General)20 kA
Nominal discharge current In(8/20) µs (line-earth) (General)50 kA
Nominal discharge current In(8/20) µs (line-shield) (General)50 kA
Permissible HF power Pmaxat VSWR = xx (50 ohm system) (General)≤ 500 W
Pulse discharge current Iimp(10/350) µs (line-earth) (General)≤ 20 kA
Output voltage limitation at 1 kV/µs (line-earth) spike (General)≤ 11 V (6 kV / 3 kA)
Output voltage limitation at 1 kV/µs (line-earth) static (General)≤ 11 V (6 kV / 3 kA)
Output voltage limitation at 1 kV/µs (line-shield) spike (General)≤ 11 V (6 kV / 3 kA)
Max. discharge current Imax(8/20) µs maximum (line-earth) (General)60 kA
Output voltage limitation at 1 kV/µs (line-shield) static (General)≤ 11 V (6 kV / 3 kA)
Max. discharge current Imax(8/20) µs maximum (line-shield) (General)60 kA

Product Description

Adapter with Lambda/4 technology as surge protection for coaxial signal interfaces. Connection: N Female-Female Connectors
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top