Key Specifications
:C3
Note:2005
Type:Attachment plug
Depth:89 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
C3
Note2005
TypeAttachment plug
Depth89 mm
Width26.1 mm
Height66 mm
Product typeSurge protection for transceiver systems
Mounting typeConnection-specific intermediate plugging
Seal materialSilicon
Frequency range0.82 GHz ... 2.2 GHz
Open side panelNo
Housing materialBrass (CuZn)
Connection methodN connector 50 Ω
Direction of actionLine-Shield/Earth Ground
Degree of protectionIP68
Standards/regulationsIEC 61643-21
VDE requirement classC2
IEC test classificationC2
Housing surface materialNi
Inner conductor materialBeCu
Insulation body materialPTFE
Standards/specificationsIEC 61643-21
Input attenuation aE, asym.typ. 0.05 dB (≤ 0.15 dB)
Surge protection fault messagenone
Total surge current (8/20) µs60 kA
Ambient temperature (operation)-40 °C ... 90 °C
Impulse durability (line-earth)C2 - 10 kV / 5 kA
Impulse durability (line-shield)C2 - 10 kV/5 kA
Inner conductor surface materialGold
Total surge current (10/350) µs20 kA
Voltage protection level Up(line-earth)≤ 12 V (6 kV / 3 kA)
Voltage protection level Up(line-shield)≤ 12 V (6 kV / 3 kA)
Pulse discharge current Iimp(10/350) µs20 kA
Voltage standing wave ratio VSWR in a 50 Ω systemtyp. 1.10 (≤ 1.20 (0.82 GHz...2.2 GHz))
Nominal discharge current In(8/20) µs (line-ground)50 kA
Nominal discharge current In(8/20) µs (line-shield)50 kA
Permissible HF power Pmaxat VSWR = xx (50 ohm system)≤ 500 W
Pulse discharge current Iimp(10/350) µs (line-earth)20 kA
Impulse discharge current (10/350) µs, peak value limp20 kA
Output voltage limitation at 1 kV/µs (line-earth) spike≤ 12 V (6 kV / 3 kA)
Output voltage limitation at 1 kV/µs (line-earth) static≤ 12 V (6 kV / 3 kA)
Output voltage limitation at 1 kV/µs (line-shield) spike≤ 12 V (6 kV / 3 kA)
Max. discharge current Imax(8/20) µs maximum (line-earth)60 kA
Output voltage limitation at 1 kV/µs (line-shield) static≤ 12 V (6 kV / 3 kA)
Max. discharge current Imax(8/20) µs maximum (line-shield)60 kA

Product Description