| Parameter | Value |
|---|---|
| GTIN | 4046356367943 |
| Note | Made to Order (non-returnable) |
| Orderkey | 2800021 |
| (General) | D1 - 2.5 kA |
| Catalog page | Page 178 (C-4-2017) |
| Packing unit | 1 pc |
| Country of origin | US (United States) |
| Custom tariff number | 85363010 |
| Rated current (General) | 5 A (25 °C) |
| Frequency range (General) | 380 MHz ... 470 MHz |
| Type (Ambient conditions) | Attachment plug |
| Color (Ambient conditions) | nickel |
| Depth (Key Commercial Data) | 83 mm |
| Width (Key Commercial Data) | 32 mm |
| (Standards and Regulations) | No hazardous substances above threshold values |
| Height (Key Commercial Data) | 32 mm |
| VDE requirement class (General) | C2 |
| Degree of protection (Dimensions) | IP68 |
| IEC test classification (General) | C2 |
| Mounting type (Ambient conditions) | Connection-specific intermediate plugging |
| Weight per Piece (excluding packing) | 187.700 g |
| Housing material (Ambient conditions) | Brass (CuZn) |
| Input attenuation aE, asym. (General) | typ. 0.05 dB (≤ 0.10 dB) |
| China RoHS (Standards and Regulations) | Environmentally friendly use period: unlimited = EFUP-e |
| Connection method (Protective circuit) | N Connector |
| Standards/regulations (Connection data) | IEC 61643-21 |
| Direction of action (Ambient conditions) | Line-Shield/Earth Ground |
| Number of positions (Ambient conditions) | 1 |
| Surge protection fault message (General) | none |
| Connection method IN (Protective circuit) | N connector, female |
| Impulse durability (line-earth) (General) | C2 - 10 kV/5 kA |
| Connection method OUT (Protective circuit) | N connector, female |
| Impulse durability (line-shield) (General) | C2 - 10 kV/5 kA |
| Standards/specifications (Connection data) | IEC 61643-21 2005 |
| Ambient temperature (operation) (Dimensions) | -40 °C ... 90 °C |
| Voltage protection level Up(line-earth) (General) | ≤ 95 V (C2 - 10 kV / 5 kA) |
| Pulse discharge current Iimp(10/350) µs (General) | ≤ 15 kA |
| Total discharge current Itotal(8/20) µs (General) | 30 kA |
| Voltage protection level Up(line-shield) (General) | ≤ 95 V (C2 - 10 kV / 5 kA) |
| Standing wave ratio SWR in a 50 Ω system (General) | typ. 1.05 (≤ 1,15) |
| Total discharge current Itotal(10/350) µs (General) | 15 kA |
| Nominal discharge current In(8/20) µs (line-earth) (General) | 20 kA |
| Nominal discharge current In(8/20) µs (line-shield) (General) | 20 kA |
| Permissible HF power Pmaxat VSWR = xx (50 ohm system) (General) | ≤ 800 W |
| Output voltage limitation at 1 kV/µs (line-earth) spike (General) | ≤ 55 V (6 kV / 3 kA) |
| Output voltage limitation at 1 kV/µs (line-earth) static (General) | ≤ 55 V (6 kV / 3 kA) |
| Output voltage limitation at 1 kV/µs (line-shield) spike (General) | ≤ 55 V (6 kV / 3 kA) |
| Max. discharge current Imax(8/20) µs maximum (line-earth) (General) | 30 kA |
| Output voltage limitation at 1 kV/µs (line-shield) static (General) | ≤ 55 V (6 kV / 3 kA) |
| Max. discharge current Imax(8/20) µs maximum (line-shield) (General) | 30 kA |
Technical specifications and performance data