

| Parameter | Value |
|---|---|
| GTIN | 4055626729312 |
| Orderkey | 1065730 |
| (General) | ≤ 29.5 V DC (inactive) |
| (Drawings) | |
| Catalog page | Page 375 (C-4-2019) |
| Packing unit | 1 |
| (Dimensions) | ≤ 4000 m up to 46 °C (amsl (above mean sea level)) |
| Depth (Drawings) | 98 mm (incl. DIN rail 7.5 mm) |
| Width (Drawings) | 36 mm |
| ETIM 5.0 (eCl@ss) | EC000899 |
| ETIM 6.0 (eCl@ss) | EC000899 |
| ETIM 7.0 (eCl@ss) | EC000899 |
| Height (Drawings) | 90 mm |
| (Connection data) | EN 50178 |
| Fuse type (General) | electronic |
| Custom tariff number | 85363030 |
| Efficiency (General) | > 99 % |
| Altitude (Dimensions) | ≤ 3000 m up to 52 °C (amsl (above mean sea level)) |
| Rated voltage (General) | 24 V DC |
| Tripping method (General) | EG (electronic - galvanic disconnection) |
| Type (Ambient conditions) | DIN rail module, one-piece |
| Color (Ambient conditions) | light grey RAL 7035 |
| Humidity test (Dimensions) | 96 h, 95 % RH, 40 °C |
| Rated current IN (General) | max. 32 A DC (IN+) |
| Connection name (Signaling) | Main circuit OUT |
| Fail-safe element (General) | 15 A DC (per output channel) |
| Operating voltage (General) | 18 V DC ... 30 V DC |
| Power dissipation (General) | typ. 2 W (No-load operation) |
| (Remote indication contact) | two flashes (Channel switched off, device total current limit 32 A exceeded) |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Stripping length (Signaling) | 10 mm |
| eCl@ss 8.0 (Classifications) | 27141116 |
| eCl@ss 9.0 (Classifications) | 27141116 |
| Connection method (Signaling) | Push-in connection |
| Dielectric strength (General) | max. 35 V DC (Load circuit) |
| Feedback resistance (General) | max. 35 V DC |
| Rated surge voltage (General) | 0.5 kV |
| Application drawing (Drawings) | |
| Required backup fuse (General) | not required, integrated failsafe element, supplied with standard switched-mode power supply |
| Temperature derating (General) | 25 A DC (at 60 °C) |
| Measuring tolerance I (General) | ± 15 % |
| eCl@ss 10.0.1 (Classifications) | 27140401 |
| Connection name (Electrical data) | Remote indication circuit |
| Degree of protection (Dimensions) | IP20 |
| Mounting type (Ambient conditions) | DIN rail: 35 mm |
| Stripping length (Electrical data) | 10 mm |
| Closed circuit current I0 (General) | typ. 80 mA |
| Module initialization time (General) | 1.6 s |
| Shutdown time load circuit (General) | ≤ 10 ms (for short circuit > 2.0 x IN) |
| Switching function (Electrical data) | N/O contact |
| Protection class (Ambient conditions) | III |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| DC operating current (Electrical data) | 100 mA DC |
| DC operating voltage (Electrical data) | 0 V DC ... 30 V DC |
| REACh SVHC (Standards and Regulations) | Lead 7439-92-1 |
| Conductor cross section AWG (Signaling) | 24 ... 12 |
| Number of positions (Ambient conditions) | 1 |
| Conductor cross section solid (Signaling) | 0.2 mm² ... 2.5 mm² |
| Standards/specifications (Connection data) | EN 61000-6-2 |
| Channel LED off (Remote indication contact) | off (Channel switched off) |
| Channel LED red (Remote indication contact) | lit (Channel switched off, relay error, overvoltage or undervoltage active) |
| Max. capacitive load load circuit (General) | 45000 µF (Depending on the current setting and the short-circuit current available) |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 60 °C |
| Undervoltage shutdown load circuit (General) | ≤ 17.8 V DC (active) |
| Channel LED green (Remote indication contact) | lit (Channel switched on) |
| Conductor cross section AWG (Electrical data) | 24 ... 12 |
| Surge voltage shutdown load circuit (General) | ≥ 30.5 V DC (active) |
| Channel LED yellow (Remote indication contact) | lit (Channel switched on, channel load > 80% ) |
| Conductor cross section solid (Electrical data) | 0.2 mm² ... 2.5 mm² |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 70 °C |
| Waiting time after switch off of a channel (General) | 5 s (at overload / short circuit) |
| Flammability rating according to UL 94 (Ambient conditions) | V-0 |
| Conductor cross section, flexible, with ferrule, with plastic sleeve (Signaling) | 0.25 mm² ... 1.5 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve (Signaling) | 0.25 mm² ... 2.5 mm² |
| DiagramMax. permissible current in relation to the ambient temperature (Drawings) | |
| Conductor cross section, flexible, with ferrule, with plastic sleeve (Electrical data) | 0.25 mm² ... 1.5 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve (Electrical data) | 0.25 mm² ... 2.5 mm² |
Technical specifications and performance data
Installation and operation guide