| Parameter | Value |
|---|---|
| GTIN | 4046356992367 |
| Orderkey | 2905744 |
| (General) | ≤ 29.5 V DC (inactive) |
| Catalog page | Page 314 (C-4-2017) |
| Packing unit | 1 pc |
| (Dimensions) | 24.9 Hz … 150 Hz (Acceleration 4g; in accordance with IEC 60068-2-6, Test Fc with additional resonance frequency testing in accordance with DNV GL) |
| Country of origin | DE (Germany) |
| (Connection data) | EN 60068-2-78 |
| Fuse type (General) | electronic |
| Custom tariff number | 85362010 |
| Efficiency (General) | > 99 % |
| Altitude (Dimensions) | ≤ 6000 m (amsl (above mean sea level)) |
| Rated voltage (General) | 24 V DC |
| Tripping method (General) | E (electronic) |
| Type (Ambient conditions) | DIN rail module, one-piece |
| Color (Ambient conditions) | light grey RAL 7035 |
| Humidity test (Dimensions) | 240 h, 95 % RH, 40 °C |
| Rated current IN (General) | max. 80 A DC (for double supply IN+ with at least 2 x 6 mm²) |
| Connection name (Signaling) | Main circuit OUT |
| Depth (Key Commercial Data) | 121 mm |
| Fail-safe element (General) | 15 A DC (per output channel) |
| Operating voltage (General) | 18 V DC ... 30 V DC |
| Power dissipation (General) | 1.2 W (No-load operation) |
| Width (Key Commercial Data) | 41 mm |
| (Remote indication contact) | flashing (Overvoltage shutdown inactive, device was in overvoltage shutdown) |
| (Standards and Regulations) | No hazardous substances above threshold values |
| Height (Key Commercial Data) | 130 mm |
| Stripping length (Signaling) | 10 mm |
| Connection method (Signaling) | Push-in connection |
| Dielectric strength (General) | max. 30 V DC (Load circuit) |
| Feedback resistance (General) | max. 35 V DC |
| Rated surge voltage (General) | 0.5 kV |
| Required backup fuse (General) | not required, integrated failsafe element |
| Shock (operation) (Dimensions) | 30g (IEC 60068-2-27, Test Ea) |
| Temperature derating (General) | 40 A DC (at 70°C (65°C for UL 2367)) |
| Measuring tolerance I (General) | typ. 40 % (0.5 A ... 1 A) |
| Connection name (Electrical data) | Remote indication circuit |
| Degree of protection (Dimensions) | IP20 |
| Mounting type (Ambient conditions) | DIN rail: 35 mm |
| Stripping length (Electrical data) | 10 mm |
| Vibration (operation) (Dimensions) | 5 Hz ... 24.9 Hz (Amplitude ±1.6 mm; in accordance with IEC 60068-2-6, Test Fc) |
| Active current limitation (General) | typ. 2.0 x IN(0.5 - 1 A) |
| Closed circuit current I0 (General) | typ. 50 mA |
| Input voltage reset input (General) | 7 V DC ... 30 V DC (Reset with falling edge) |
| MTBF (IEC 61709, SN 29500) (General) | 1304293 h (at 25 °C) |
| Module initialization time (General) | 3.3 s |
| Shutdown time load circuit (General) | 0.02 s (> 1.3 x IN) |
| Switching function (Electrical data) | N/O contact |
| Weight per Piece (excluding packing) | 325.000 g |
| Protection class (Ambient conditions) | III |
| China RoHS (Standards and Regulations) | Environmentally friendly use period: unlimited = EFUP-e |
| DC operating current (Electrical data) | 1 mA DC ... 100 mA DC |
| DC operating voltage (Electrical data) | 0 V DC ... 30 V DC |
| Output current status output (General) | max. 20 mA (when I > 80% at at least one channel) |
| Output voltage status output (General) | 24 V DC |
| REACh SVHC (Standards and Regulations) | Lead 7439-92-1 |
| Conductor cross section AWG (Signaling) | 24 ... 12 |
| Number of positions (Ambient conditions) | 8 |
| Conductor cross section solid (Signaling) | 0.2 mm² ... 2.5 mm² |
| Current consumption reset input (General) | typ. 0.4 mA (at 24 V DC) |
| DC OK LED off (Remote indication contact) | off (No supply voltage) |
| DC OK LED red (Remote indication contact) | lit (Overvoltage shutdown active, voltage ≥ 30.5 V, channels switched off and channel LEDs are lit red) |
| Standards/specifications (Connection data) | EN 61000-6-2 |
| Channel LED off (Remote indication contact) | off (Channel switched off) |
| Channel LED red (Remote indication contact) | lit (Channel switched off, over- or undervoltage active) |
| DC OK LED green (Remote indication contact) | lit (Operating voltage in nominal range 18 ... 30 V) |
| Max. capacitive load load circuit (General) | 75000 µF (per channel at 24 V DC) |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 70 °C (Startup at -40 C type-tested) |
| DC OK LED yellow (Remote indication contact) | lit (Undervoltage active, voltage ≤ 17.8 V, active channels switched off and channel LEDs are lit red) |
| Undervoltage shutdown load circuit (General) | ≤ 17.8 V DC (active) |
| Channel LED green (Remote indication contact) | lit (Channel switched on) |
| Conductor cross section AWG (Electrical data) | 24 ... 12 |
| Surge voltage shutdown load circuit (General) | ≥ 30.5 V DC (active) |
| Channel LED yellow (Remote indication contact) | lit (Channel switched on, channel load > 80% ) |
| Conductor cross section solid (Electrical data) | 0.2 mm² ... 2.5 mm² |
| Channel LED red-green (Remote indication contact) | flashing (Channel switched off, programming mode active, current adjustment after overload or short-circuit release) |
| Channel LED red-yellow (Remote indication contact) | flashing (Channel switched on, overload mode, capacity approximately 110 ... 130% , shutdown after 30 s) |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 80 °C |
| Channel LED yellow-green (Remote indication contact) | flashing (Channel switched on, nominal current assistant active) |
| Waiting time after switch off of a channel (General) | 10 s (at overload / short circuit) |
| Flammability rating according to UL 94 (Ambient conditions) | V-0 |
| Conductor cross section, flexible, with ferrule, with plastic sleeve (Signaling) | 0.25 mm² ... 1.5 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve (Signaling) | 0.25 mm² ... 2.5 mm² |
| Conductor cross section, flexible, with ferrule, with plastic sleeve (Electrical data) | 1.5 mm² ... 0.25 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve (Electrical data) | 0.25 mm² ... 2.5 mm² |
Technical specifications and performance data
Installation and operation guide