Service time: Monday to Friday 9:00-18:00
C-UB/E - C-UB/E 2763701 PHOENIX CONTACT Surge protection device
In Stock Hot Product

C-UB/E

C-UB/E 2763701 PHOENIX CONTACT Surge protection device

$0.00USD
3861 in stock
Key Specifications
GTIN:4017918065638
Orderkey:2763701
Catalog page:Page 177 (C-4-2017)
Packing unit:10 pc
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4017918065638
Orderkey2763701
Catalog pagePage 177 (C-4-2017)
Packing unit10 pc
Note (General)To meet the discharge conditions for DC voltages, please note the following information: "The surge protective device should be used together with a transmitter unit, which shuts down in the event of a short-circuit."
Country of originDE (Germany)
Custom tariff number85363010
Altitude (Dimensions)≤ 2000 m (amsl (above mean sea level))
Type (Ambient conditions)Attachment plug
(Additional descriptions)D1 - 2.5 kA
Depth (Key Commercial Data)80 mm
Width (Key Commercial Data)25.4 mm
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Height (Key Commercial Data)25.4 mm
Degree of protection (Dimensions)IP20
Mounting type (Ambient conditions)Connection-specific intermediate plugging
Connection method (Connection data)PVC litz wire
(Connection, equipotential bonding)EN 61643-21 2013
Weight per Piece (excluding packing)102.400 g
Housing material (Ambient conditions)Aluminum
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Connection method (Protective circuit)BNC 50 Ω
Rated current (Additional descriptions)3.5 A (25 °C)
Direction of action (Ambient conditions)Line-Shield/Earth Ground
Connection method IN (Protective circuit)BNC socket
Connection method OUT (Protective circuit)BNC plug
Response time tA (Additional descriptions)≤ 100 ns
Ambient temperature (operation) (Dimensions)-40 °C ... 80 °C
Residual current IPE (Additional descriptions)≤ 2 µA
IEC test classification (Additional descriptions)C2
Input attenuation aE, asym. (Additional descriptions)typ. 0.1 dB (≤ 100 MHz/50 Ω)
Maximum continuous voltage UC (Additional descriptions)180 V DC
Capacity asymmetrical (shield) (Additional descriptions)typ. 6 pF
Surge protection fault message (Additional descriptions)none
Impulse durability (line-earth) (Additional descriptions)C2 - 10 kV/5 kA
Impulse durability (line-shield) (Additional descriptions)C2 - 10 kV/5 kA
Residual voltage at In(line-earth) (Additional descriptions)≤ 160 V (1.5 m cable)
Standards/specifications (Connection, equipotential bonding)IEC 61643-21 2012
Operating effective current ICat UC (Additional descriptions)≤ 1 µA
Residual voltage at In(line-shield) (Additional descriptions)≤ 55 V
Residual voltage at In(shield-earth) (Additional descriptions)≤ 160 V (1.5 m cable)
Voltage protection level Up(line-earth) (Additional descriptions)≤ 500 V (C2 - 10 kV / 5 kA)
Total discharge current Itotal(8/20) µs (Additional descriptions)10 kA
Voltage protection level Up(line-shield) (Additional descriptions)≤ 700 V (C2 - 10 kV / 5 kA)
Standing wave ratio SWR in a 50 Ω system (Additional descriptions)typ. 1.3 (≤ 150 MHz)
Voltage protection level Up(shield-ground) (Additional descriptions)≤ 500 V (C2 - 10 kV / 5 kA)
Nominal discharge current In(8/20) µs (line-earth) (Additional descriptions)5 kA
Nominal discharge current In(8/20) µs (line-shield) (Additional descriptions)5 kA
Nominal discharge current In(8/20) µs (shield-earth) (Additional descriptions)5 kA
Permissible HF power Pmaxat VSWR = xx (50 ohm system) (Additional descriptions)300 W (VSWR = 1.1)
Pulse discharge current Iimp(10/350) µs (line-earth) (Additional descriptions)2.5 kA
Pulse discharge current Iimp(10/350) µs (line-shield) (Additional descriptions)2.5 kA
Output voltage limitation at 1 kV/µs (line-earth) spike (Additional descriptions)≤ 470 V
Output voltage limitation at 1 kV/µs (line-earth) static (Additional descriptions)≤ 33 V
Output voltage limitation at 1 kV/µs (line-shield) spike (Additional descriptions)≤ 590 V
Output voltage limitation at 1 kV/µs (line-shield) static (Additional descriptions)≤ 33 V
Output voltage limitation at 1 kV/µs (shield-earth) spike (Additional descriptions)≤ 470 V
Output voltage limitation at 1 kV/µs (shield-earth) static (Additional descriptions)≤ 33 V
Cut-off frequency fg (3 dB), asym. (shield) in 50 Ohm system (Additional descriptions)typ. 1 GHz

Product Description

Adapter with surge protection for coaxial signal interfaces with display without earth potential. Connection: Female-male BNC
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top