| Parameter | Value |
|---|---|
| GTIN | 4017918915186 |
| Note | Made to Order (non-returnable) |
| Orderkey | 2857002 |
| (General) | D1 - 500 A |
| Catalog page | Page 181 (C-4-2017) |
| Packing unit | 1 pc |
| Country of origin | DE (Germany) |
| (Connection data) | EN 50083 CLASS-A |
| Custom tariff number | 85363010 |
| Altitude (Dimensions) | ≤ 2000 m (amsl (above mean sea level)) |
| Rated current (General) | 1.5 A (25 °C) |
| Frequency range (General) | 4.7 MHz ... 860 MHz |
| Type (Ambient conditions) | Attachment plug |
| Color (Ambient conditions) | jet black RAL 9005 |
| Depth (Key Commercial Data) | 61 mm |
| Width (Key Commercial Data) | 28 mm |
| Height (Key Commercial Data) | 40 mm |
| Residual current IPE (General) | ≤ 1 µA |
| Degree of protection (Dimensions) | IP20 |
| IEC test classification (General) | C1 |
| Mounting type (Ambient conditions) | Connection-specific intermediate plugging |
| Weight per Piece (excluding packing) | 53.500 g |
| Housing material (Ambient conditions) | PA 6.6 |
| Input attenuation aE, asym. (General) | typ. 0.5 dB (≤ 2.4 GHz /75 Ω) |
| Connection method (Protective circuit) | PAL-TV (IEC 169-2) |
| Maximum continuous voltage UC (General) | 24 V DC |
| Capacity asymmetrical (shield) (General) | typ. 10 pF |
| Degree of pollution (Ambient conditions) | 2 |
| Direction of action (Ambient conditions) | Line-Shield/Earth Ground |
| Number of positions (Ambient conditions) | 1 |
| Pulse reset time (line-shield) (General) | < 3 s |
| Response time tA (line-shield) (General) | ≤ 100 ns |
| Surge protection fault message (General) | none |
| Connection method IN (Protective circuit) | Socket |
| Overvoltage category (Ambient conditions) | II |
| Connection method OUT (Protective circuit) | Male |
| Impulse durability (line-shield) (General) | C2 - 4 kV/2 kA |
| Standards/specifications (Connection data) | IEC 61643-21 2012 |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 75 °C |
| Operating effective current ICat UC (General) | ≤ 1 µA |
| Residual voltage at In(line-shield) (General) | ≤ 30 V |
| Voltage protection level Up(line-shield) (General) | ≤ 700 V (C2 - 4 kV / 2 kA) |
| Flammability rating according to UL 94 (Ambient conditions) | V-0 |
| Alternating current carrying capacity (line-shield) (General) | 5 A - 1 s |
| Nominal discharge current In(8/20) µs (line-shield) (General) | 2.5 kA |
| Nominal pulse current Ian (10/1000) µs (Core-Shield) (General) | 120 A |
| Output voltage limitation at 1 kV/µs (line-shield) spike (General) | ≤ 600 V |
| Output voltage limitation at 1 kV/µs (line-shield) static (General) | ≤ 600 V |
| Cut-off frequency fg (3 dB), asym. (shield) in 75 Ohm system (General) | > 1 GHz |
Technical specifications and performance data