| Parameter | Value |
|---|---|
| GTIN | 4046356048941 |
| Orderkey | 2880561 |
| (General) | D1 - 5 kA |
| Catalog page | Page 180 (C-4-2017) |
| Packing unit | 1 pc |
| Country of origin | DE (Germany) |
| Custom tariff number | 85363010 |
| (Ambient conditions) | DIN VDE 0110-1 |
| Altitude (Dimensions) | ≤ 4000 m (amsl (above mean sea level)) |
| Rated current (General) | 400 mA |
| Frequency range (General) | 47 MHz ... 2.5 GHz |
| Type (Ambient conditions) | Housing for surface mounting |
| Color (Ambient conditions) | silver |
| Depth (Key Commercial Data) | 71.5 mm |
| Width (Key Commercial Data) | 144.9 mm |
| Height (Key Commercial Data) | 31.5 mm |
| Nominal voltage UN (General) | 14 V DC (vertical) |
| Residual current IPE (General) | ≤ 2 µA (per channel) |
| Resistance in series (General) | 3.3 Ω ±20 % |
| Inductivity in series (General) | typ. 5 µH (f = 10 kHz) |
| Degree of protection (Dimensions) | IP40 |
| IEC test classification (General) | B2 |
| Mounting type (Ambient conditions) | Screw mounting |
| Connection method (Connection data) | Screw connection |
| (Connection, equipotential bonding) | EN 50083-2 CLASS-A |
| Weight per Piece (excluding packing) | 228.240 g |
| Housing material (Ambient conditions) | Zinc die-cast |
| Input attenuation aE, asym. (General) | ≤ 1 dB (5 MHz ... 2,2 GHz / 75 Ω) |
| Connection method (Protective circuit) | F connector |
| Maximum continuous voltage UC (General) | 20 V DC |
| Degree of pollution (Ambient conditions) | 2 |
| Direction of action (Ambient conditions) | Line-Shield/Earth Ground |
| Near-end crosstalk attenuation (General) | ≥ 40 dB (5 MHz ... 2,4 GHz / 75 Ω) |
| Number of positions (Ambient conditions) | 5 |
| Response time tA (line-shield) (General) | ≤ 1 ns |
| Surge protection fault message (General) | none |
| Connection method IN (Protective circuit) | F connector, female |
| Overvoltage category (Ambient conditions) | II |
| Connection method OUT (Protective circuit) | F connector, female |
| Impulse durability (line-shield) (General) | B2 - 4 kV/100 A |
| Impulse durability (shield-earth) (General) | C2 - 10 kA |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 55 °C |
| Operating effective current ICat UC (General) | ≤ 2 µA (per channel) |
| Total discharge current Itotal(8/20) µs (General) | 10 kA |
| Voltage protection level Up(line-shield) (General) | ≤ 500 V (C2 - 4 kV / 2 kA) |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 80 °C |
| Standards/specifications (Connection, equipotential bonding) | IEC 61643-21 2000 + A1:2008 + A2:2012 |
| Nominal discharge current In(8/20) µs (line-shield) (General) | 2.5 kA |
| Nominal pulse current Ian (10/700) µs (Core-Shield) (General) | 100 A |
| Nominal pulse current Ian (10/1000) µs (Core-Shield) (General) | 100 A |
| Standards for cearances and creepage distances (Ambient conditions) | IEC 60664-1 |
| Output voltage limitation at 1 kV/µs (line-shield) static (General) | ≤ 80 V |
| Max. discharge current Imax(8/20) µs maximum (line-shield) (General) | 2.5 kA |
| Cut-off frequency fg (3 dB), asym. (shield) in 75 Ohm system (General) | > 2.5 GHz |
Technical specifications and performance data