Service time: Monday to Friday 9:00-18:00
BT-1S-230AC/A - BT-1S-230AC/A 2803409 PHOENIX CONTACT Type 3 surge protection device
In Stock Hot Product

BT-1S-230AC/A

BT-1S-230AC/A 2803409 PHOENIX CONTACT Type 3 surge protection device

$0.00USD
4714 in stock
Key Specifications
:TT
Note:2011
Type:Installation module
Color:black (RAL 9005)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
TT
Note2011
TypeInstallation module
Colorblack (RAL 9005)
Depth26.2 mm
Width22.5 mm
Height43 mm
EN typeT3
Altitude≤ 2000 m (amsl)
Product typeDevice protection
Mounting typeScrew mounting
Product familyBLOCKTRAB
Number of portsOne
Article revision08
Housing materialPA 6.6
Pollution degree2
Connection methodSpring-cage connection
Mode of protectionL-N
Nominal voltage UN230/400 V AC (TN-S)
Dimensional drawing
Direction of actionL(N)-PE
Insulating materialPA 6.6
Number of positions2
Combination wave UOC6 kV
Degree of protectionIP20
Nominal frequency fN50 Hz (60 Hz)
Overvoltage categoryIII
Residual current IPE≤ 3 µA
CTI value of material600
Rated load current IL16 A (30 °C)
Response time tA(L-N)≤ 25 ns
Standards/regulationsEN 60664-1 / IEC 60664-1 / IEC 61643-1 / EN 61643-11
Response time tA(L-PE)≤ 100 ns
IEC power supply systemTN-S
IEC test classificationIII
TOV behavior at UT(L-N)335 V AC (5 s / withstand mode)
Standards/specificationsIEC 61643-11
TOV behavior at UT(L-PE)440 V AC (5 s / withstand mode)
TOV behavior at UT(N-PE)1200 V AC (200 ms / safe failure mode)
Conductor cross section AWG24 ... 14
Reference test voltage UREF255 V AC
Standby power consumption PC≤ 400 mVA
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Surge protection fault messageAcoustic
Ambient temperature (operation)-30 °C ... 75 °C
Residual voltage at Iamax, (PE)≤ 1.5 kV (at UOC)
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Permissible humidity (operation)5 % ... 95 %
Residual voltage at Iamax, (L-N)≤ 1.3 kV (at UOC)
Voltage protection level Up(L-N)≤ 1.3 kV
Residual voltage at Iamax, (L-PE)≤ 1.5 kV (at UOC)
Voltage protection level Up(L-PE)≤ 1.5 kV
Voltage protection level Up(N-PE)≤ 1.5 kV
Short-circuit current rating ISCCR1 kA AC
Max. backup fuse with branch wiring16 A (MCB B)
Flammability rating according to UL 94V-0
Nominal discharge current In(8/20) µs3 kA
Ambient temperature (storage/transport)-30 °C ... 75 °C
Distance between live and grounded parts3 mm
Maximum discharge current Imax(8/20) µs8 kA
Maximum continuous operating voltage UC(L-N)275 V AC
Maximum continuous operating voltage UC(L-PE)440 V AC
Maximum continuous operating voltage UC(N-PE)440 V AC

Product Description

Type 3 unloader for universal mounting in installation boxes, gutters, recessed installations or directly on the terminal equipment. Temperature-controlled circuit, acoustic defect indication. Install
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top