Service time: Monday to Friday 9:00-18:00
BLT-T2-1S-305-UT - BLT-T2-1S-305-UT 1078433 PHOENIX CONTACT Type 2 surge arrester for universal mounting in lights, cable conne..
In Stock Hot Product

BLT-T2-1S-305-UT

BLT-T2-1S-305-UT 1078433 PHOENIX CONTACT Type 2 surge arrester for universal mounting in lights, cable conne..

$0.00USD
4124 in stock
Key Specifications
GTIN:4055626793344
Orderkey:1078433
(General):440 V AC (120 min / safe failure mode)
(Drawings):
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626793344
Orderkey1078433
(General)440 V AC (120 min / safe failure mode)
(Drawings)
Catalog pagePage 76 (C-4-2019)
Packing unit1
Depth (Drawings)34 mm
Width (Drawings)36.5 mm
ETIM 5.0 (eCl@ss)EC000941
ETIM 6.0 (eCl@ss)EC000941
ETIM 7.0 (eCl@ss)EC000941
Height (Drawings)56 mm
(Connection data)EN 61643-11 2012
Custom tariff number85354000
(Ambient conditions)N-PE
Altitude (Dimensions)≤ 2000 m (amsl (above mean sea level))
Color (Ambient conditions)light grey RAL 7035
EN type (Ambient conditions)T2 / T3
Nominal voltage UN (General)100 V AC ... 230 V AC (TN-S)
eCl@ss 8.0 (Classifications)27130805
eCl@ss 9.0 (Classifications)27130805
Dimensional drawing (Drawings)
Nominal frequency fN (General)50 Hz (60 Hz)
Residual current IPE (General)≤ 5 µA
Shock (operation) (Dimensions)25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Rated load current IL (General)16 A
Response time tA(L-N) (General)≤ 25 ns
Response time tA(L-PE) (General)≤ 100 ns
Response time tA(N-PE) (General)≤ 100 ns
Degree of protection (Dimensions)IP20
Screw thread (Protective circuit)M3
TOV behavior at UT(L-N) (General)336 V AC (5 s / withstand mode)
Accessibility (Ambient conditions)Accessible
Mounting type (Ambient conditions)4 mm screw
TOV behavior at UT(L-PE) (General)440 V AC (5 s / withstand mode)
TOV behavior at UT(N-PE) (General)1200 V AC (200 ms / safe failure mode)
Vibration (operation) (Dimensions)5g (5 ... 500 Hz / 2.5 h / X, Y, Z)
Combination wave UOC(L-N) (General)10 kV
Combination wave UOC(L-PE) (General)10 kV
Combination wave UOC(N-PE) (General)20 kV
Housing material (Ambient conditions)PA 6.6
Protection class (Ambient conditions)I
Stripping length (Protective circuit)8 mm
Connection method (Protective circuit)Screw terminal blocks
REACh SVHC (Standards and Regulations)Lead 7439-92-1
Tightening torque (Protective circuit)0.6 Nm
Mode of protection (Ambient conditions)L-N
Standards/regulations (Connection data)IEC 61643-11 2011
Degree of pollution (Ambient conditions)2
SPD failure behavior (Ambient conditions)OCM
Voltage protection level Up(L-N) (General)≤ 1.3 kV
Voltage protection level Up(L-PE) (General)≤ 1.5 kV
Voltage protection level Up(N-PE) (General)≤ 1.5 kV
Ambient temperature (operation) (Dimensions)-40 °C ... 80 °C
IEC power supply system (Ambient conditions)TN-S
IEC test classification (Ambient conditions)II / III
Short-circuit current rating ISCCR (General)10 kA (6 A gG backup fuse)
Max. backup fuse with branch wiring (General)16 A (MCB B/C)
Maximum continuous voltage UC(N-PE) (General)265 V AC
Permissible humidity (operation) (Dimensions)5 % ... 95 %
Conductor cross section solid (Protective circuit)0.2 mm² ... 4 mm²
Follow current interrupt rating Ifi(N-PE) (General)100 A ()
Total discharge current Itotal(8/20) µs (General)20 kA
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 80 °C
Conductor cross section flexible (Protective circuit)0.2 mm² ... 2.5 mm²
Max. backup fuse with V-type through wiring (General)16 A (MCB B/C)
Maximum continuous operating voltage UC(L-N) (General)305 V AC
Nominal discharge current In(8/20) µs (L-N) (General)5 kA
Maximum continuous operating voltage UC(L-PE) (General)265 V AC
Nominal discharge current In(8/20) µs (L-PE) (General)5 kA
Nominal discharge current In(8/20) µs (N-PE) (General)10 kA
Maximum discharge current Imax(8/20) µs (L-N) (General)10 kA
Maximum discharge current Imax(8/20) µs (L-PE) (General)10 kA
Maximum discharge current Imax(8/20) µs (N-PE) (General)20 kA
Flammability rating according to UL 94 (Ambient conditions)V-0
Distance between live and grounded parts (Ambient conditions)3 mm
Installation location of the disconnect device (Ambient conditions)Internal
2 conductors with same cross section, solid max. (Protective circuit)1.5 mm²
2 conductors with same cross section, solid min. (Protective circuit)0.2 mm²
2 conductors with same cross section, stranded max. (Protective circuit)1.5 mm²
2 conductors with same cross section, stranded min. (Protective circuit)0.2 mm²

Product Description

Type 2 surge arrester for universal mounting on lights, cable junction boxes, installation boxes, wall channels, underfloor installations or directly on terminal equipment. Special for insulation prot
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Dimensional drawing

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top