| Parameter | Value |
|---|---|
| GTIN | 4055626592442 |
| Orderkey | 1038842 |
| (General) | 1455 V AC (200 ms / safe failure mode) |
| Packing unit | 1 pc |
| Country of origin | DE (Germany) |
| (Connection data) | EN 61643-11 2012 |
| Custom tariff number | 85363010 |
| (Ambient conditions) | N-PE |
| Altitude (Dimensions) | ≤ 2000 m (amsl (above mean sea level)) |
| Type (Ambient conditions) | Socket mounting module |
| Color (Ambient conditions) | light grey RAL 7035 |
| Depth (Key Commercial Data) | 32 mm |
| Width (Key Commercial Data) | 53 mm |
| EN type (Ambient conditions) | T3 |
| Height (Key Commercial Data) | 53 mm |
| Nominal voltage UN (General) | 230 V AC (TN-S) |
| Combination wave UOC (General) | 6 kV |
| Nominal frequency fN (General) | 50 Hz (60 Hz) |
| Residual current IPE (General) | ≤ 5 µA |
| Response time tA(L-N) (General) | ≤ 25 ns |
| Response time tA(L-PE) (General) | ≤ 100 ns |
| Response time tA(N-PE) (General) | ≤ 100 ns |
| Degree of protection (Dimensions) | IP20 (Installed) |
| TOV behavior at UT(L-N) (General) | 440 V AC (5 s / withstand mode) |
| Mounting type (Ambient conditions) | in device sockets of insulating material with standard ground contact sockets |
| TOV behavior at UT(L-PE) (General) | 440 V AC (5 s / withstand mode) |
| TOV behavior at UT(N-PE) (General) | 1200 V AC (200 ms / safe failure mode) |
| Max. required back-up fuse (General) | 16 A (MCB B) |
| Number of ports (Ambient conditions) | One |
| Weight per Piece (excluding packing) | 41.000 g |
| Housing material (Ambient conditions) | PA 6.6-FR |
| Reference test voltage UREF (General) | 255 V AC |
| Voltage protection level Up (General) | ≤ 1.5 kV |
| Connection method (Protective circuit) | Single wires |
| REACh SVHC (Standards and Regulations) | Lead 7439-92-1 |
| Maximum continuous voltage UC (General) | 255 V AC |
| Mode of protection (Ambient conditions) | L-N |
| Degree of pollution (Ambient conditions) | 2 |
| Number of positions (Ambient conditions) | 2 |
| Standards/specifications (Connection data) | IEC 61643-11 2011 |
| Ambient temperature (operation) (Dimensions) | -20 °C ... 70 °C |
| IEC power supply system (Ambient conditions) | TN-S |
| Short-circuit current rating ISCCR (General) | 1 kA AC |
| Permissible humidity (operation) (Dimensions) | 5 % ... 95 % |
| Max. discharge current Imax(8/20) µs (General) | 4 kA |
| Surge protection fault message (Ambient conditions) | Acoustic |
| Ambient temperature (storage/transport) (Dimensions) | -20 °C ... 70 °C |
| Flammability rating according to UL 94 (Ambient conditions) | V-0 |