| Parameter | Value |
|---|---|
| GTIN | 4017918147556 |
| Note | Made to Order (non-returnable) |
| Orderkey | 3025956 |
| Catalog page | Page 241 (C-3-2013) |
| Packing unit | 10 pc |
| Width (General) | 7.62 mm |
| Length (General) | 225 mm |
| Country of origin | PL (Poland) |
| Custom tariff number | 85369010 |
| (Key Commercial Data) | 1.5 mm² / 0.4 kg |
| Height NS 35/15 (General) | 89.5 mm |
| Height NS 35/7,5 (General) | 82 mm |
| Color (Key Commercial Data) | gray |
| (Standards and Regulations) | No hazardous substances above threshold values |
| Stripping length (Dimensions) | 8 mm |
| Connection method (Dimensions) | Spring-cage connection |
| Setpoint (Key Commercial Data) | 1 N |
| Weight per Piece (excluding packing) | 77.660 g |
| Open side panel (Key Commercial Data) | Yes |
| China RoHS (Standards and Regulations) | Environmentally friendly use period: unlimited = EFUP-e |
| Number of levels (Key Commercial Data) | 8 |
| Finger protection (Key Commercial Data) | guaranteed |
| Max. load current (Key Commercial Data) | 10 A (with 1.5 mm² conductor cross section) |
| Bending test turns (Key Commercial Data) | 135 |
| Nominal current IN (Key Commercial Data) | 10 A |
| Nominal voltage UN (Key Commercial Data) | 250 V |
| Short-time current (Key Commercial Data) | 0.18 kA |
| Degree of pollution (Key Commercial Data) | 3 |
| Insulating material (Key Commercial Data) | PC |
| Rated surge voltage (Key Commercial Data) | 4 kV |
| Tensile test result (Key Commercial Data) | Test passed |
| Overvoltage category (Key Commercial Data) | III |
| Result of aging test (Key Commercial Data) | Test passed |
| Tight fit on carrier (Key Commercial Data) | NS 35 |
| Nominal cross section (Key Commercial Data) | 1 mm² |
| Number of connections (Key Commercial Data) | 32 |
| Result of bending test (Key Commercial Data) | Test passed |
| Result of thermal test (Key Commercial Data) | Test passed |
| Conductor cross section AWG max. (Dimensions) | 14 |
| Conductor cross section AWG min. (Dimensions) | 26 |
| Tractive force setpoint (Key Commercial Data) | 40 N |
| Conductor cross section solid max. (Dimensions) | 1.5 mm² |
| Conductor cross section solid min. (Dimensions) | 0.14 mm² |
| Insulating material group (Key Commercial Data) | IIIa |
| Requirements, voltage drop (Key Commercial Data) | ≤ 3.2 mV |
| Back of the hand protection (Key Commercial Data) | guaranteed |
| Bending test rotation speed (Key Commercial Data) | 10 rpm |
| Result of voltage-drop test (Key Commercial Data) | Test passed |
| Surge voltage test setpoint (Key Commercial Data) | 4.8 kV |
| Conductor cross section flexible max. (Dimensions) | 1 mm² |
| Conductor cross section flexible min. (Dimensions) | 0.14 mm² |
| Connection in acc. with standard (Connection data) | IEC 60947-7-1 |
| Result of surge voltage test (Key Commercial Data) | Test passed |
| Result of tight fit on support (Key Commercial Data) | Test passed |
| Short circuit stability result (Key Commercial Data) | Test passed |
| Result of temperature-rise test (Key Commercial Data) | Test passed |
| Connection in acc. with standard (Key Commercial Data) | IEC 60947-7-1 |
| Flammability rating according to UL 94 (Connection data) | V0 |
| Shock protection test specification (Key Commercial Data) | DIN EN 50274 (VDE 0660-514):2002-11 |
| Conductor cross section tensile test (Key Commercial Data) | 1.5 mm² |
| Flammability rating according to UL 94 (Key Commercial Data) | V0 |
| Power frequency withstand voltage setpoint (Key Commercial Data) | 1.5 kV |
| Bending test conductor cross section/weight (Key Commercial Data) | 0.14 mm² / 0.2 kg |
| Conductor cross section short circuit testing (Key Commercial Data) | 1.5 mm² |
| Maximum power dissipation for nominal condition (Key Commercial Data) | 0.56 W (the value is multiplied when connecting multiple levels) |
| Result of power-frequency withstand voltage test (Key Commercial Data) | Test passed |
| Conductor cross section flexible, with ferrule with plastic sleeve max. (Dimensions) | 0.75 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. (Dimensions) | 0.14 mm² |
| Relative insulation material temperature index (Elec., UL 746 B) (Key Commercial Data) | 125 °C |
| Conductor cross section flexible, with ferrule without plastic sleeve max. (Dimensions) | 0.75 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve min. (Dimensions) | 0.14 mm² |
| Proof of thermal characteristics (needle flame) effective duration (Key Commercial Data) | 30 s |
| Ageing test for screwless modular terminal block temperature cycles (Key Commercial Data) | 192 |
| Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) (Key Commercial Data) | 130 °C |
| Result of the test for mechanical stability of terminal points (5 x conductor connection) (Key Commercial Data) | Test passed |
Technical specifications and performance data