Service time: Monday to Friday 9:00-18:00
XN-2AI-PT/NI-2/3 - XN-2AI-PT/NI-2/3 140067 Y7-140067 EATON ELECTRIC Analog input card XI/ON, 24 V DC, 2AI (PT100, 200, 500, 100..
In Stock Hot Product

XN-2AI-PT/NI-2/3

XN-2AI-PT/NI-2/3 140067 Y7-140067 EATON ELECTRIC Analog input card XI/ON, 24 V DC, 2AI (PT100, 200, 500, 100..

$0.00USD
3492 in stock
Key Specifications
Feature Name:Feature Value
Depth (EF000049):55.4 mm
Width (EF000008):12.6 mm
Height (EF000040):74.1 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Feature NameFeature Value
Depth (EF000049)55.4 mm
Width (EF000008)12.6 mm
Height (EF000040)74.1 mm
IO link master (EF007298)No
Input, current (EF003204)No
Input, voltage (EF003205)No
Input, resistor (EF003206)Yes
Output, current (EF003212)No
Output, voltage (EF003213)No
System accessory (EF004118)Yes
Supply voltage DC (EF007534)20.4 V
Radio standard GSM (EF008524)No
Input, thermocouple (EF003208)No
Radio standard GPRS (EF008523)No
Radio standard UMTS (EF008525)No
Rack-assembly possible (EF007018)No
Front built-in possible (EF007016)No
Supply voltage AC 50 Hz (EF007532)0 V
Supply voltage AC 60 Hz (EF007533)0 V
Radio standard Bluetooth (EF007178)No
Degree of protection (IP) (EF005474)IP20
Number of analogue inputs (EF001994)2
Input signal, configurable (EF003209)Yes
Number of analogue outputs (EF001995)0
Output signal configurable (EF003214)No
Radio standard WLAN 802.11 (EF007179)No
SIL according to IEC 61508 (EF009889)None
Suitable for rail mounting (EF003972)Yes
Degree of protection (NEMA) (EF011959)1
Number of HW-interfaces USB (EF003025)0
Supporting protocol for ASI (EF003051)No
Supporting protocol for CAN (EF003053)No
Supporting protocol for KNX (EF003055)No
Supporting protocol for LON (EF003017)No
Type of electric connection (EF003961)Screw-/spring clamp connection
Analogue inputs configurable (EF008518)Yes
Analogue outputs configurable (EF008519)Yes
Input, resistance thermometer (EF003207)Yes
Number of HW-interfaces other (EF003027)1
Number of interfaces PROFINET (EF006932)0
Suitable for safety functions (EF001597)No
Voltage type (supply voltage) (EF002991)DC
Wall mounting/direct mounting (EF007020)No
Number of HW-interfaces RS-232 (EF003021)0
Number of HW-interfaces RS-422 (EF003022)0
Number of HW-interfaces RS-485 (EF003023)0
Supporting protocol for Modbus (EF003057)No
Supporting protocol for SERCOS (EF006657)No
Supporting protocol for TCP/IP (EF003050)No
Supporting protocol for SUCONET (EF003060)No
Number of HW-interfaces parallel (EF003026)0
Number of HW-interfaces wireless (EF006933)0
Supporting protocol for EtherCAT (EF017564)No
Supporting protocol for INTERBUS (EF003054)No
Supporting protocol for PROFIBUS (EF003052)No
Appendant operation agent (Ex ia) (EF004141)No
Appendant operation agent (Ex ib) (EF004142)No
Explosion safety category for gas (EF003997)None
Resolution of the analogue inputs (EF003575)16 Bit
Supporting protocol for DeviceNet (EF003059)No
Supporting protocol for PROFIsafe (EF007526)No
Explosion safety category for dust (EF003998)None
Number of HW-interfaces serial TTY (EF003024)0
Resolution of the analogue outputs (EF003577)0 Bit
Supporting protocol for EtherNet/IP (EF007521)No
Supporting protocol for PROFINET IO (EF007525)No
Supporting protocol for SafetyBUS p (EF007527)No
Supporting protocol for Data-Highway (EF003058)No
Supporting protocol for PROFINET CBA (EF007524)No
Supporting protocol for INTERBUS-Safety (EF006662)No
Supporting protocol for DeviceNet Safety (EF007520)No
Supporting protocol for other bus systems (EF003062)Yes
Certified for UL hazardous location class I (EF017622)No
Number of HW-interfaces industrial Ethernet (EF003020)0
Supporting protocol for Foundation Fieldbus (EF007522)No
Certified for UL hazardous location class II (EF017625)No
Certified for UL hazardous location class III (EF017627)No
Performance level according to EN ISO 13849-1 (EF007399)None
Certified for UL hazardous location division 1 (EF017628)No
Certified for UL hazardous location division 2 (EF017629)No
Supporting protocol for AS-Interface Safety at Work (EF007519)No
Certified for UL hazardous location group D (propane) (EF017636)No
Certified for UL hazardous location group B (hydrogen) (EF017633)No
Certified for UL hazardous location group C (ethylene) (EF017635)No
Fieldbus connection over separate bus coupler possible (EF004002)Yes
Certified for UL hazardous location group A (acetylene) (EF017632)No
Certified for UL hazardous location group E (metal dusts) (EF017637)No
Certified for UL hazardous location group F (carbonaceous dusts) (EF017638)No
Certified for UL hazardous location group G (non-conductive dusts) (EF017639)No

Product Description

XN-2AI-PT/NI-2/3
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top