| Parameter | Value |
|---|---|
| 66.3 dB (at 4 МHz) | |
| Type | Plug straight RJ45 |
| Material | Metal |
| Shielded | yes |
| Shielding | Tinned copper braided shield |
| Cable type | Ethernet 10 Gbit |
| Sensor type | Ethernet |
| Cable length | 5.00 m |
| Cable outlet | straight |
| Cable weight | 42 kg/km |
| Halogen-free | according to IEC 60754-1 |
| Locking type | Push Pull |
| Product type | Data cable preassembled |
| Short symbol | 02YSC11Y |
| UL AWM Style | 20963 (80°C/30 V) |
| Overall twist | 4 pairs for core |
| Twisted pairs | 2 cores to the pair |
| Cable capacity | 47 nF/km |
| Signal runtime | 5.13 ns/m |
| Wave impedance | 100 Ω |
| AWG signal line | 26 |
| Cable structure | 4x2xAWG26/7; S/FTP |
| Loop resistance | ≤ 290.00 Ω/km |
| Article revision | 09 |
| Flame resistance | according to IEC 60332-1-2 |
| Tensile strength | ≤ 100 N |
| Resistance to oil | in accordance with DIN EN 60811-2-1 |
| Conductor material | Bare Cu litz wires |
| Shield attenuation | ≥ 80.00 dB (at 30 ... 100 MHz) |
| Single wire, color | white/blue-blue, white/orange-orange, white/green-green, white/brown-brown |
| Transmission speed | 1 Gbps |
| Degree of pollution | 2 |
| Dimensional drawing | |
| Number of positions | 8 |
| Transmission medium | Copper |
| Degree of protection | IP67 |
| No. of cable outlets | 1 |
| Signal type/category | Ethernet CAT6A, 10 Gbps |
| External sheath, color | water blue RAL 5021 |
| Nominal voltage, cable | ≤ 100 V |
| Outer sheath, material | PUR |
| Test voltage Core/Core | 700 V (50 Hz, 1 min.) |
| Type of pair shielding | Aluminum-lined foil |
| Conductor cross section | 4x 2x 0.14 mm² |
| External cable diameter | 6.40 mm ±0.2 mm |
| Optical shield covering | 70 % |
| Return attenuation (RL) | 20 dB (with 1 MHz) |
| Thickness, outer sheath | 0.65 mm |
| Material wire insulation | Foamed PE |
| Test voltage Core/Shield | 700.00 V (50 Hz, 1 min.) |
| Cable type (abbreviation) | 94F |
| Cable insulation resistance | ≥ 500 MΩ*km |
| Insertion/withdrawal cycles | ≥ 200 |
| Wire diameter incl. insulation | 1.04 mm |
| Ambient temperature (operation) | -20 °C ... 80 °C (Cable, flexible installation) |
| Conductor structure signal line | 7x 0.16 mm |
| Near end crosstalk attenuation (NEXT) | 75.3 dB (with 1 MHz) |
| Flammability rating according to UL 94 | V2 |
| Transmission characteristics (category) | CAT6 |
| Minimum bending radius, fixed installation | 4 x D |
| Minimum bending radius, flexible installation | 8 x D |
| Power-summated near end crosstalk attenuation (PSNEXT) | 72.3 dB (with 1 MHz) |
Technical specifications and performance data