| Parameter | Value |
|---|---|
| GTIN | 4046356434300 |
| Note | Made to Order (non-returnable) |
| Orderkey | 1575437 |
| Packing unit | 1 pc |
| Country of origin | PL (Poland) |
| Custom tariff number | 85444290 |
| Minimum order quantity | 50 pc |
| (Line characteristics) | No hazardous substances above threshold values |
| (Electrical characteristics) | -40 °C ... 70 °C (cable, flexible installation) |
| (Mechanical characteristics) | -20 °C ... 70 °C (cable, flexible installation) |
| Shielded (Key Commercial Data) | yes |
| China RoHS (Line characteristics) | Environmentally friendly use period: unlimited = EFUP-e |
| Cable diameter (Key Commercial Data) | 6.50 mm |
| Weight per Piece (excluding packing) | 678.800 g |
| Cable structure (Key Commercial Data) | 1x4xAWG22/7; SF-UTP |
| Housing material (Ambient conditions) | TPU/PA |
| Length of cable (Key Commercial Data) | 2 m |
| Shielding (Electrical characteristics) | Aluminum-coated foil, tinned copper braided shield |
| Cable type (Electrical characteristics) | PROFINET PVC stranded CAT5 |
| Wire colors (Electrical characteristics) | White, yellow, blue, orange |
| Cable weight (Electrical characteristics) | 67 kg/km |
| Number of positions (Key Commercial Data) | 4 |
| Signal speed (Electrical characteristics) | 0.66 c |
| UL AWM style (Electrical characteristics) | 21694 |
| Degree of protection (Key Commercial Data) | IP67/IP20 |
| Overall twist (Electrical characteristics) | Star quad |
| External sheath, color (Ambient conditions) | green-yellow RAL 6018 |
| Outer sheath, material (Ambient conditions) | PVC |
| Signal runtime (Electrical characteristics) | 5.3 ns/m |
| Wave impedance (Electrical characteristics) | 100 Ω ±15 Ω (at 100 MHz) |
| AWG signal line (Electrical characteristics) | 22 |
| Cable structure (Electrical characteristics) | 1x4xAWG22/7; SF/TQ |
| Flame resistance (Electrical characteristics) | according to UL 1685 (CSA FT 4) |
| Other resistance (Electrical characteristics) | UV resistant According to UL 1581, Section 1200 |
| Wave attenuation (Electrical characteristics) | 2.1 dB (with 1 MHz) |
| Resistance to oil (Electrical characteristics) | Resistant to oil to a limited extent |
| Cable abbreviation (Electrical characteristics) | 2YY(ST)CY |
| Conductor material (Electrical characteristics) | Tin-plated Cu litz wires |
| Coupling resistance (Electrical characteristics) | ≤ 20.00 mΩ/m (at 10 MHz) |
| Transmission medium (Electrical characteristics) | Copper |
| Insertion/withdrawal cycles (Key Commercial Data) | ≥ 100 |
| Insulation resistance (Electrical characteristics) | ≥ 500 MΩ*km |
| External sheath, color (Electrical characteristics) | green RAL 6018 |
| Material, inner sheath (Electrical characteristics) | PVC |
| Nominal voltage, cable (Electrical characteristics) | 600 V |
| Outer sheath, material (Electrical characteristics) | PVC |
| Test voltage Core/Core (Electrical characteristics) | 2000 V (50 Hz, 1 min.) |
| Conductor cross section (Electrical characteristics) | 4x 0.34 mm² |
| External cable diameter (Electrical characteristics) | 6.5 mm ±0.2 mm |
| Optical shield covering (Electrical characteristics) | 85 % |
| Test voltage Core/Shield (Electrical characteristics) | 2000 V (50 Hz, 1 min.) |
| Transmission characteristics (category) (Material data) | CAT5 (IEC 11801:2002) |
| Material conductor insulation (Electrical characteristics) | PE |
| Ambient temperature (operation) (Electrical characteristics) | -40 °C ... 70 °C (cable, fixed installation) |
| Ambient temperature (operation) (Mechanical characteristics) | -25 °C ... 70 °C (cable, fixed installation) |
| Conductor structure signal line (Electrical characteristics) | 7x 0.25 mm |
| Core diameter including insulation (Electrical characteristics) | 1.55 mm |
| Near end crosstalk attenuation (NEXT) (Electrical characteristics) | 80 dB (with 1 MHz) |
| Minimum bending radius, fixed installation (Electrical characteristics) | 3 x D |
| Minimum bending radius, flexible installation (Electrical characteristics) | 7 x D |
Technical specifications and performance data