| Parameter | Value |
|---|---|
| • WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible. | |
| Coding | D |
| Shielded | yes |
| Bus system | Ethernet |
| Cable type | Ethernet flexible CAT5, 2-pair [93E] |
| Head design | Socket |
| Safety note | WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property. |
| Sensor type | Ethernet |
| Thread type | M12 |
| Cable length | 5 m |
| Cable weight | 42 kg/km |
| Halogen-free | according to IEC 60754-1 |
| Product type | Data cable preassembled |
| UL AWM Style | 20963 (80°C/30 V) |
| Overall twist | Two pairs with two fillers to the core |
| Twisted pairs | 2 cores to the pair |
| Cable capacity | approx. 45 nF/km (at 1 kHz) |
| Signal runtime | 5.3 ns/m |
| Wave impedance | 100 Ω ±5 Ω (at 100 MHz) |
| AWG signal line | 26 |
| Loop resistance | ≤ 290.00 Ω/km |
| Article revision | 12 |
| Contact material | CuZn |
| Flame resistance | according to IEC 60332-1-2 |
| Head thread type | M12 |
| Tensile strength | ≤ 80 N |
| Connection method | Cable lug connection |
| Head cable outlet | straight |
| Head locking type | SPEEDCON |
| Resistance to oil | in accordance with EN 60811-2-1 |
| Conductor material | Bare Cu litz wires |
| Contact resistance | ≤ 3 mΩ |
| Nominal current IN | 4 A (Plug/socket in accordance with IEC 61076-2-101, cable technical data is to be observed) |
| Nominal voltage UN | 48 V AC |
| Notes on operation | The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration. |
| Order information: | Lock nut is included in the scope of delivery |
| Shield attenuation | 3.2 dB (with 1 MHz) |
| Single wire, color | white/orange-orange, white/green-green |
| Conductor structure | 2x2xAWG26/7, SF/UTP |
| Coupling resistance | ≤ 100.00 mΩ/m (at 10 MHz) |
| Degree of pollution | 3 |
| Dimensional drawing | |
| Number of positions | 4 |
| Transmission medium | Copper |
| Degree of protection | IP67 |
| No. of cable outlets | 1 |
| Overvoltage category | II |
| Signal type/category | Ethernet CAT5 (IEC 11801:2002), 100 Mbps |
| Standard designation | M12 connector |
| Insulation resistance | ≥ 100 MΩ |
| External sheath, color | water blue RAL 5021 |
| Nominal voltage, cable | ≤ 100 V (Peak value, not for high-power applications) |
| Outer sheath, material | PUR |
| Test voltage Core/Core | 700 V (50 Hz, 1 min.) |
| Conductor cross section | 2x 2x 0.14 mm² |
| Contact connection type | Socket |
| External cable diameter | 6.40 mm ±0.2 mm |
| Optical shield covering | 70 % |
| Return attenuation (RL) | 23 dB (at 4 МHz) |
| Thickness, outer sheath | 1.20 mm |
| Contact carrier material | PA 6.6 |
| Contact surface material | Ni/Au |
| Material wire insulation | Foamed PE |
| Standards/specifications | IEC 61076-2-101 |
| Test voltage Core/Shield | 700.00 V (50 Hz, 1 min.) |
| Insertion/withdrawal cycles | ≥ 100 |
| Wiring standards/regulations | Electrical requirements EN 50288-2-2 |
| Wire diameter incl. insulation | 0.98 mm |
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) |
| Conductor structure signal line | 7x 0.16 mm |
| Ambient temperature (installation) | -20 °C ... 80 °C |
| Current carrying capacity of cable | 2.00 A (according to DIN VDE 0891-1) |
| Near end crosstalk attenuation (NEXT) | 65.3 dB (with 1 MHz) |
| Flammability rating according to UL 94 | V0 |
| Transmission characteristics (category) | CAT5 (IEC 11801:2002) |
| Minimum bending radius, fixed installation | 4 x D |
| Smallest bending radius, fixed installation | 26 mm |
| Minimum bending radius, flexible installation | 8 x D |
| Smallest bending radius, movable installation | 52 mm |
| Power-summated near end crosstalk attenuation (PSNEXT) | 62.3 dB (with 1 MHz) |
Technical specifications and performance data
Installation and operation guide