Service time: Monday to Friday 9:00-18:00
VS-M12FSEC-OE-93E-LI/5,0 - VS-M12FSEC-OE-93E-LI/5,0 1404245 PHOENIX CONTACT Network cable
In Stock Hot Product

VS-M12FSEC-OE-93E-LI/5,0

VS-M12FSEC-OE-93E-LI/5,0 1404245 PHOENIX CONTACT Network cable

$0.00USD
3306 in stock
Key Specifications
:• WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible.
Coding:D
Shielded:yes
Bus system:Ethernet
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
• WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible.
CodingD
Shieldedyes
Bus systemEthernet
Cable typeEthernet flexible CAT5, 2-pair [93E]
Head designSocket
Safety noteWARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property.
Sensor typeEthernet
Thread typeM12
Cable length5 m
Cable weight42 kg/km
Halogen-freeaccording to IEC 60754-1
Product typeData cable preassembled
UL AWM Style20963 (80°C/30 V)
Overall twistTwo pairs with two fillers to the core
Twisted pairs2 cores to the pair
Cable capacityapprox. 45 nF/km (at 1 kHz)
Signal runtime5.3 ns/m
Wave impedance100 Ω ±5 Ω (at 100 MHz)
AWG signal line26
Loop resistance≤ 290.00 Ω/km
Article revision12
Contact materialCuZn
Flame resistanceaccording to IEC 60332-1-2
Head thread typeM12
Tensile strength≤ 80 N
Connection methodCable lug connection
Head cable outletstraight
Head locking typeSPEEDCON
Resistance to oilin accordance with EN 60811-2-1
Conductor materialBare Cu litz wires
Contact resistance≤ 3 mΩ
Nominal current IN4 A (Plug/socket in accordance with IEC 61076-2-101, cable technical data is to be observed)
Nominal voltage UN48 V AC
Notes on operationThe electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration.
Order information:Lock nut is included in the scope of delivery
Shield attenuation3.2 dB (with 1 MHz)
Single wire, colorwhite/orange-orange, white/green-green
Conductor structure2x2xAWG26/7, SF/UTP
Coupling resistance≤ 100.00 mΩ/m (at 10 MHz)
Degree of pollution3
Dimensional drawing
Number of positions4
Transmission mediumCopper
Degree of protectionIP67
No. of cable outlets1
Overvoltage categoryII
Signal type/categoryEthernet CAT5 (IEC 11801:2002), 100 Mbps
Standard designationM12 connector
Insulation resistance≥ 100 MΩ
External sheath, colorwater blue RAL 5021
Nominal voltage, cable≤ 100 V (Peak value, not for high-power applications)
Outer sheath, materialPUR
Test voltage Core/Core700 V (50 Hz, 1 min.)
Conductor cross section2x 2x 0.14 mm²
Contact connection typeSocket
External cable diameter6.40 mm ±0.2 mm
Optical shield covering70 %
Return attenuation (RL)23 dB (at 4 МHz)
Thickness, outer sheath1.20 mm
Contact carrier materialPA 6.6
Contact surface materialNi/Au
Material wire insulationFoamed PE
Standards/specificationsIEC 61076-2-101
Test voltage Core/Shield700.00 V (50 Hz, 1 min.)
Insertion/withdrawal cycles≥ 100
Wiring standards/regulationsElectrical requirements EN 50288-2-2
Wire diameter incl. insulation0.98 mm
Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)
Conductor structure signal line7x 0.16 mm
Ambient temperature (installation)-20 °C ... 80 °C
Current carrying capacity of cable2.00 A (according to DIN VDE 0891-1)
Near end crosstalk attenuation (NEXT)65.3 dB (with 1 MHz)
Flammability rating according to UL 94V0
Transmission characteristics (category)CAT5 (IEC 11801:2002)
Minimum bending radius, fixed installation4 x D
Smallest bending radius, fixed installation26 mm
Minimum bending radius, flexible installation8 x D
Smallest bending radius, movable installation52 mm
Power-summated near end crosstalk attenuation (PSNEXT)62.3 dB (with 1 MHz)

Product Description

Conect. plug. to be apar. front wall, CAT5 Ethernet (100 MBit/s), Ethernet, 4-pole, PUR, water blue RAL5021, shielded, Built-in mounting female, straight, M12-SPEEDCON, encoding: D, free cable end, Fr
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top