| Parameter | Value |
|---|---|
| EtherCAT® CAT5 (IEC 11801), 100 Mbps | |
| Type | Plug straight RJ45 |
| Shielded | yes |
| Shielding | Aluminum-coated foil, tinned copper braided shield |
| Cable type | PROFINET PVC stranded CAT5 |
| Sensor type | Ethernet |
| Cable length | 2.00 m |
| Cable outlet | straight |
| Cable weight | 67 kg/km |
| Product type | Data cable preassembled |
| Short symbol | 2YY(ST)CY |
| Signal speed | 0.66 c |
| UL AWM Style | 21694 |
| Overall twist | Star quad |
| Rated current | 1.75 A |
| Signal runtime | 5.3 ns/m |
| Wave impedance | 100 Ω |
| AWG signal line | 22 |
| Cable structure | 1x4xAWG22/7, SF/TQ |
| Loop resistance | ≤ 120.00 Ω/km |
| Article revision | 04 |
| Flame resistance | according to UL 1685 (CSA FT 4) |
| Other resistance | UV resistant (according to UL 1581, Section 1200) |
| Connection method | IDC fast connection |
| Resistance to oil | Resistant to oil to a limited extent |
| Conductor material | Tin-plated Cu litz wires |
| Single wire, color | white, yellow, blue, orange |
| Transmission speed | 100 Mbps |
| Coupling resistance | ≤ 20.00 mΩ/m (at 10 MHz) |
| Degree of pollution | 1 |
| Dimensional drawing | |
| Number of positions | 4 |
| Transmission medium | Copper |
| Degree of protection | IP20 |
| No. of cable outlets | 1 |
| Signal type/category | PROFINET CAT5 (IEC 11801), 100 Mbps |
| Rated voltage (III/3) | 50 V |
| External sheath, color | green RAL 6018 |
| Material, inner sheath | PVC |
| Nominal voltage, cable | 600 V |
| Outer sheath, material | PVC |
| Test voltage Core/Core | 2000 V (50 Hz, 1 min.) |
| Conductor cross section | 4x 0.34 mm² |
| External cable diameter | 6.50 mm ±0.2 mm |
| Optical shield covering | 85 % |
| Thickness, outer sheath | approx. 0.90 mm |
| Material wire insulation | PE |
| Test voltage Core/Shield | 2000.00 V (50 Hz, 1 min.) |
| Cable type (abbreviation) | 93B |
| Cable insulation resistance | ≥ 500 MΩ*km |
| Insertion/withdrawal cycles | ≥ 1000 |
| Wire diameter incl. insulation | 1.55 mm |
| Ambient temperature (operation) | -40 °C ... 70 °C (Cable, flexible installation) |
| Conductor structure signal line | 7x 0.25 mm |
| Insertion force per signal contact | 50.00 N |
| Extraction force per signal contact | 30 N |
| Near end crosstalk attenuation (NEXT) | 80 dB (with 1 MHz) |
| Flammability rating according to UL 94 | V0 |
| Transmission characteristics (category) | CAT5 (IEC 11801:2002) |
| Minimum bending radius, fixed installation | 3 x D |
| Minimum bending radius, flexible installation | 7 x D |
Technical specifications and performance data