| Parameter | Value |
|---|---|
| 50 V DC (Power and data) | |
| Coding | Y |
| Material | Zinc die-cast (nickel-plated) |
| Shielded | yes |
| Cable type | Ethernet hybrid |
| Cable length | 3 m |
| Product type | Circular connectors (device side) |
| Mounting type | Rear mounting |
| Seal material | FKM |
| Wave impedance | 100 Ω |
| AWG signal line | 26 |
| Cable structure | 2x2xAWG26 + 1x4xAWG20 |
| AWG power supply | 20 |
| Contact material | CuZn |
| Conductor material | Bare Cu litz wires |
| Contact resistance | ≤ 3 mΩ |
| Nominal current IN | 6 A (Power) |
| Nominal voltage UN | 48 V AC (Power and data) |
| Notes on operation | The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration. |
| Single wire, color | Ethernet: white/orange-orange, white/green-greenPower: white, blue, brown, black |
| Cable cross section | 0.15 mm² |
| Degree of pollution | 3 |
| Number of positions | 8 |
| Rated surge voltage | 0.8 kV |
| Transmission medium | Copper |
| Degree of protection | IP67 |
| Overvoltage category | III |
| Insulation resistance | ≥ 100 MΩ |
| External sheath, color | black RAL 9005 |
| Outer sheath, material | PUR mixture halogen-free |
| Test voltage Core/Core | 1.5 kV AC (Core - core) |
| External cable diameter | 7.60 mm |
| Contact carrier material | PPA |
| Contact surface material | Au |
| Test voltage Core/Shield | 1.50 kV AC (Line-shield) |
| Insertion/withdrawal cycles | ≥ 100 |
| Wire diameter incl. insulation | 1.05 mm |
| Ambient temperature (operation) | -40 °C ... 90 °C (fixed routing) |
| Conductor structure signal line | 4x 1.05 mm |
| Conductor structure, voltage supply | 4x 1.40 mm |
| Flammability rating according to UL 94 | V0 |
| Transmission characteristics (category) | CAT5 (IEC 11801:2002) |
| Smallest bending radius, movable installation | min. 110 mm |