| Parameter | Value |
|---|---|
| GTIN | 4046356339247 |
| Note | Made to Order (non-returnable) |
| Orderkey | 1404935 |
| Catalog page | Page 438 (C-2-2017) |
| Packing unit | 1 pc |
| Country of origin | DE (Germany) |
| Custom tariff number | 85444995 |
| (Line characteristics) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Height (Ambient conditions) | 4 mm |
| (Standards and Regulations) | -30 °C ... 105 °C (cable, flexible installation) |
| (Mechanical characteristics) | -40 °C ... 105 °C (fixed routing) |
| Shielded (Key Commercial Data) | no |
| China RoHS (Line characteristics) | Environmentally Friendly Use Period = 50 |
| Rated surge voltage (Material data) | 2 kV |
| Type of cable (Key Commercial Data) | Flat-ribbon conductor |
| Weight per Piece (excluding packing) | 6,453.000 g |
| Cable structure (Key Commercial Data) | 2x 1.5 mm² |
| Length of cable (Key Commercial Data) | 100 m |
| Rated voltage (III/3) (Material data) | 300 V |
| Wire colors (Standards and Regulations) | brown, blue |
| Acceleration (Standards and Regulations) | 4 m/s² |
| Cable weight (Standards and Regulations) | 64 kg/km |
| Duty cycle testing (Key Commercial Data) | suitable for drag chain |
| Halogen-free (Standards and Regulations) | no |
| Number of positions (Key Commercial Data) | 2 |
| Type of cable (Standards and Regulations) | Flat-ribbon conductor |
| Bending radius (Standards and Regulations) | 50 mm |
| Cable structure (Standards and Regulations) | 2x 1.5 mm² |
| External sheath, color (Ambient conditions) | black RAL 9005 |
| Outer sheath, material (Ambient conditions) | TPE |
| Traversing rate (Standards and Regulations) | 4 m/s |
| AWG power supply (Standards and Regulations) | 16 |
| Flame resistance (Standards and Regulations) | UL 1581, Sec. 1061 (Cable Flame) |
| Other resistance (Standards and Regulations) | UV resistant |
| Resistance to oil (Standards and Regulations) | UL 1581, Sec. 480 (60 °C) |
| Conductor material (Standards and Regulations) | Bare Cu litz wires |
| Special properties (Standards and Regulations) | UL-Style 2103 |
| Duty cycle testing (Electrical characteristics) | suitable for drag chain |
| Max. bending cycles (Standards and Regulations) | 10000000 |
| Test voltage, cable (Standards and Regulations) | 2000 V |
| Conductor resistance (Standards and Regulations) | ≤ 13.7 Ω/km |
| Traversing direction (Standards and Regulations) | vertical, above the broadside |
| Insulation resistance (Standards and Regulations) | ≥ 1 MΩ*km |
| Thickness, insulation (Standards and Regulations) | approx. 0.5 mm |
| External sheath, color (Standards and Regulations) | black RAL 9005 |
| Nominal voltage, cable (Standards and Regulations) | 300 V |
| Outer sheath, material (Standards and Regulations) | TPE |
| Conductor cross section (Standards and Regulations) | 1.5 mm² |
| Material conductor insulation (Standards and Regulations) | TPE |
| Ambient temperature (assembly) (Mechanical characteristics) | -30 °C ... 105 °C |
| Ambient temperature (operation) (Standards and Regulations) | -40 °C ... 105 °C (cable, fixed installation) |
| Ambient temperature (operation) (Mechanical characteristics) | -30 °C ... 105 °C (Flexibly installed) |
| Core diameter including insulation (Standards and Regulations) | 2.5 mm |
| Conductor structure, voltage supply (Standards and Regulations) | 84x 0.15 mm |
| Ambient temperature (storage/transport) (Mechanical characteristics) | -40 °C ... 105 °C |
| Smallest bending radius, fixed installation (Standards and Regulations) | ≥ 6 mm (one-time) |
Technical specifications and performance data