Key Specifications
:IEC 60947-7-1
Note:Please observe the current carrying capacity of the DIN rails.
Color:gray (RAL 7042)
Width:6.2 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
IEC 60947-7-1
NotePlease observe the current carrying capacity of the DIN rails.
Colorgray (RAL 7042)
Width6.2 mm
Height91.5 mm
GeneralCurrent and voltage are determined by the plug used.
Product typeGround terminal block
Screw threadM3
Mounting typeNS 35/7,5
Grounding footYes
Number of rows4
Nominal current24 A
Nominal voltage250 V (the voltage is determined by the component used)
Open side panelNo
Article revision03
Stripping length8 mm
Cross section AWG24 ... 12 (converted acc. to IEC)
Tightening torque0.5 ... 0.6 Nm
Depth on NS 35/1577.5 mm
Degree of pollution3
Depth on NS 35/7,570 mm
Insulating materialPA
Rated surge voltage4 kV
Maximum load current24 A (with 4 mm² conductor cross section)
Overvoltage categoryIII
Nominal cross section2.5 mm²
Number of connections7
Insulating material groupI
Internal cylindrical gageA3
Conductor cross section rigid0.2 mm² ... 4 mm²
Ambient temperature (assembly)-5 °C ... 70 °C
Ambient temperature (actuation)-5 °C ... 70 °C
Ambient temperature (operation)-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Number of connections per level2
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Connection in acc. with standardIEC 60947-7-1/IEC 60947-7-2
Permissible humidity (operation)20 % ... 90 %
Flammability rating according to UL 94V2
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Conductor cross section, flexible [AWG]24 ... 14 (converted acc. to IEC)
Permissible humidity (storage/transport)30 % ... 70 %
Cross-section with insertion bridge, rigid4 mm²
Surface flammability NFPA 130 (ASTM E 162)passed
Cross-section with insertion bridge, flexible2.5 mm²
Static insulating material application in cold-60 °C
Maximum power dissipation for nominal condition0.77 W
Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Flexible conductor cross section (ferrule with plastic sleeve)0.25 mm² ... 2.5 mm²
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Conductor cross-section flexible (ferrule without plastic sleeve)0.25 mm² ... 2.5 mm²
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C

Product Description

Ground terminal for distribution, Current and voltage are determined by the connector used., nominal voltage: 250 V, nominal current: 24 A, connection type: Screw connection, 2nd, 3rd, and 4th floor,
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top