UTI 6-L/L - UTI 6-L/L 3076042 PHOENIX CONTACT Installation level terminal block
In Stock Hot Product

UTI 6-L/L

UTI 6-L/L 3076042 PHOENIX CONTACT Installation level terminal block

$0.00USD
3579 in stock
Key Specifications
GTIN:4046356817646
Orderkey:3076042
Packing unit:50 pc
Width (General):8.2 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356817646
Orderkey3076042
Packing unit50 pc
Width (General)8.2 mm
Length (General)95 mm
Country of originPL (Poland)
Note (Dimensions)Please observe the current carrying capacity of the DIN rails.
Custom tariff number85369010
(Key Commercial Data)10 mm² / 2 kg
Minimum order quantity50 pc
Height NS 35/15 (General)59 mm
Screw thread (Dimensions)M3
Height NS 35/7,5 (General)51.5 mm
Note (Key Commercial Data)Assembly instruction:In order to securely fix the neutral busbar in place, support brackets must be placed at the beginning and end of each terminal strip as well as every 20 cm on longer terminal strips.The corresponding support brackets can be found at phoenixcontact.net/products
Color (Key Commercial Data)gray
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Stripping length (Dimensions)9 mm
Connection method (Dimensions)Screw connection
ASD level (Key Commercial Data)6.12 (m/s2)2/Hz
Shock form (Key Commercial Data)Half-sine
Acceleration (Key Commercial Data)30g
Tightening torque max (Dimensions)0.6 Nm
Test spectrum (Key Commercial Data)Service life test category 2, bogie-mounted
Tightening torque, min (Dimensions)0.5 Nm
Shock duration (Key Commercial Data)18 ms
Test frequency (Key Commercial Data)f1= 5 Hz to f2= 250 Hz
Weight per Piece (excluding packing)27.740 g
Open side panel (Key Commercial Data)Yes
Test directions (Key Commercial Data)X-, Y- and Z-axis (pos. and neg.)
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Internal cylindrical gage (Dimensions)A5
Number of levels (Key Commercial Data)3
REACh SVHC (Standards and Regulations)Lead 7439-92-1
Finger protection (Key Commercial Data)guaranteed
Shock test result (Key Commercial Data)Test passed
Bending test turns (Key Commercial Data)135
Nominal current IN (Key Commercial Data)38 A (with 6 mm² conductor cross section)
Nominal voltage UN (Key Commercial Data)400 V
Short-time current (Key Commercial Data)1.2 kA
Degree of pollution (Key Commercial Data)3
Insulating material (Key Commercial Data)PA
Rated surge voltage (Key Commercial Data)6 kV
Tensile test result (Key Commercial Data)Test passed
Maximum load current (Key Commercial Data)47 A (with 10 mm² conductor cross section)
Overvoltage category (Key Commercial Data)III
Tight fit on carrier (Key Commercial Data)NS 35
Nominal cross section (Key Commercial Data)6 mm²
Number of connections (Key Commercial Data)4
Result of bending test (Key Commercial Data)Test passed
Result of thermal test (Key Commercial Data)Test passed
Test duration per axis (Key Commercial Data)5 h
Conductor cross section AWG max. (Dimensions)8
Conductor cross section AWG min. (Dimensions)24
Tractive force setpoint (Key Commercial Data)90 N
Conductor cross section solid max. (Dimensions)10 mm²
Conductor cross section solid min. (Dimensions)0.2 mm²
Insulating material group (Key Commercial Data)I
Requirements, voltage drop (Key Commercial Data)≤ 3.2 mV
Back of the hand protection (Key Commercial Data)guaranteed
Bending test rotation speed (Key Commercial Data)10 rpm
Result of voltage-drop test (Key Commercial Data)Test passed
Surge voltage test setpoint (Key Commercial Data)7.3 kV
Conductor cross section flexible max. (Dimensions)10 mm²
Conductor cross section flexible min. (Dimensions)0.2 mm²
Result of surge voltage test (Key Commercial Data)Test passed
NF F16-101, NF F10-102 Class F (Key Commercial Data)2
NF F16-101, NF F10-102 Class I (Key Commercial Data)2
Number of shocks per direction (Key Commercial Data)3
Result of tight fit on support (Key Commercial Data)Test passed
Short circuit stability result (Key Commercial Data)Test passed
Test specification, shock test (Key Commercial Data)DIN EN 50155 (VDE 0115-200):2008-03
Ambient temperature (operation) (Key Commercial Data)-40 °C ... 130 °C
Result of temperature-rise test (Key Commercial Data)Test passed
Oxygen index (DIN EN ISO 4589-2) (Key Commercial Data)>32 %
Flammability rating according to UL 94 (Connection data)V0
Shock protection test specification (Key Commercial Data)DIN EN 50274 (VDE 0660-514):2002-11
Conductor cross section tensile test (Key Commercial Data)10 mm²
Flame test method (DIN EN 60695-11-10) (Key Commercial Data)V0
Flammability rating according to UL 94 (Key Commercial Data)V0
Smoke gas toxicity NFPA 130 (SMP 800C) (Key Commercial Data)passed
2 conductors with same cross section, solid max. (Dimensions)2.5 mm²
2 conductors with same cross section, solid min. (Dimensions)0.2 mm²
Oscillation, broadband noise test result (Key Commercial Data)Test passed
2 conductors with same cross section, stranded max. (Dimensions)2.5 mm²
2 conductors with same cross section, stranded min. (Dimensions)0.2 mm²
Power frequency withstand voltage setpoint (Key Commercial Data)1.89 kV
Surface flammability NFPA 130 (ASTM E 162) (Key Commercial Data)passed
Bending test conductor cross section/weight (Key Commercial Data)0.2 mm² / 0.2 kg
Conductor cross section short circuit testing (Key Commercial Data)10 mm²
Static insulating material application in cold (Key Commercial Data)-60 °C
Behavior in fire for rail vehicles (DIN 5510-2) (Key Commercial Data)Test passed
Maximum power dissipation for nominal condition (Key Commercial Data)1.31 W (the value is multiplied when connecting multiple levels)
Calorimetric heat release NFPA 130 (ASTM E 1354) (Key Commercial Data)28 MJ/kg
Result of power-frequency withstand voltage test (Key Commercial Data)Test passed
Test specification, oscillation, broadband noise (Key Commercial Data)DIN EN 50155 (VDE 0115-200):2008-03
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Connection data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Connection data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Connection data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 (Connection data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Key Commercial Data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Key Commercial Data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Key Commercial Data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 (Key Commercial Data)HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662) (Key Commercial Data)passed
Conductor cross section flexible, with ferrule with plastic sleeve max. (Dimensions)6 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min. (Dimensions)0.25 mm²
Relative insulation material temperature index (Elec., UL 746 B) (Key Commercial Data)130 °C
Conductor cross section flexible, with ferrule without plastic sleeve max. (Dimensions)6 mm²
Conductor cross section flexible, with ferrule without plastic sleeve min. (Dimensions)0.25 mm²
Proof of thermal characteristics (needle flame) effective duration (Key Commercial Data)30 s
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) (Key Commercial Data)130 °C
Result of the test for mechanical stability of terminal points (5 x conductor connection) (Key Commercial Data)Test passed

Product Description

Distribution floor terminal block, nominal voltage: 400 V, nominal current: 38 A, Screw connection, Dimensioning cross-section: 6 mm², cross-section: 0.2 mm² - 10 mm², installation class: NS 35/7.5, N
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top