UTI 2,5-L/L - UTI 2,5-L/L 3076031 PHOENIX CONTACT Installation level terminal block, Screw connection, Cross section: 0.2 ..
In Stock Hot Product

UTI 2,5-L/L

UTI 2,5-L/L 3076031 PHOENIX CONTACT Installation level terminal block, Screw connection, Cross section: 0.2 ..

$0.00USD
3176 in stock
Key Specifications
:24 A (with a 2.5 mm² conductor cross section)
Note:Assembly instructions:For secure fastening of the neutral busbar, supports must be set at the beginning and end of each terminal strip as well as every 20 cm on longer terminal strips.
Color:gray
Width:5.2 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
24 A (with a 2.5 mm² conductor cross section)
NoteAssembly instructions:For secure fastening of the neutral busbar, supports must be set at the beginning and end of each terminal strip as well as every 20 cm on longer terminal strips.
Colorgray
Width5.2 mm
Length93.5 mm
Setpoint1 N
ASD level6.12 (m/s2)2/Hz
Shock formHalf-sine
Acceleration3.12 g
Screw threadM3
Test spectrumService life test category 2, bogie mounted
Shock duration18 ms
Test frequencyf1= 5 Hz to f2= 250 Hz
Height NS 35/1559 mm
Open side panelja
Test directionsX-, Y- and Z-axis
Height NS 35/7,551.5 mm
Number of levels3
Pollution degree3
Stripping length9 mm
Connection methodScrew connection
Finger protectionguaranteed
Shock test resultTest passed
Bending test turns135
Nominal current IN24 A (with 4 mm² conductor cross section)
Nominal voltage UN400 V (phase conductor/phase conductor)
Short-time current0.3 kA
Insulating materialPA
Rated surge voltage4 kV
Tensile test resultTest passed
Maximum load current30 A (with 4 mm² conductor cross section and 3-pos. terminal block)
Overvoltage categoryIII
Tight fit on carrierNS 35
Nominal cross section4 mm²
Number of connections4
Tightening torque max0.6 Nm
Result of bending testTest passed
Result of thermal testTest passed
Test duration per axis5 h
Tightening torque, min0.5 Nm
Tractive force setpoint10 N
Insulating material groupI
Internal cylindrical gageA3
Requirements, voltage drop≤ 3.2 mV
Back of the hand protectionguaranteed
Bending test rotation speed10 rpm
Result of voltage-drop testTest passed
Surge voltage test setpoint7.3 kV
Result of surge voltage testTest failed
Number of shocks per direction3
Result of tight fit on supportTest passed
Short circuit stability resultTest passed
Test specification, shock testDIN EN 50155 (VDE 0115-200):2008-03
Result of temperature-rise testTest passed
Conductor cross section AWG max.12
Conductor cross section AWG min.24
Conductor cross section solid max.4 mm²
Conductor cross section solid min.0.2 mm²
Shock protection test specificationDIN EN 50274 (VDE 0660-514):2002-11
Conductor cross section tensile test0.2 mm²
Conductor cross section flexible max.4 mm²
Conductor cross section flexible min.0.2 mm²
Flammability rating according to UL 94V0
Oscillation, broadband noise test resultTest passed
Power frequency withstand voltage setpoint1.89 kV
Bending test conductor cross section/weight0.2 mm² / 0.2 kg
Conductor cross section short circuit testing2.5 mm²
Static insulating material application in cold-60 °C
Current carrying capacity of the neutral busbar140 A
2 conductors with same cross section, solid max.1.5 mm²
2 conductors with same cross section, solid min.0.2 mm²
Result of power-frequency withstand voltage testTest performed
Test specification, oscillation, broadband noiseDIN EN 50155 (VDE 0115-200):2008-03
2 conductors with same cross section, stranded max.1.5 mm²
2 conductors with same cross section, stranded min.0.2 mm²
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Proof of thermal characteristics (needle flame) effective duration30 s
Conductor cross section flexible, with ferrule with plastic sleeve max.2.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.0.25 mm²
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C
Conductor cross section flexible, with ferrule without plastic sleeve max.2.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve min.0.25 mm²
2 conductors with same cross section, stranded, ferrules without plastic sleeve, max.0.75 mm²
2 conductors with same cross section, stranded, ferrules without plastic sleeve, min.0.25 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max.0.75 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min.0.5 mm²
Result of the test for mechanical stability of terminal points (5 x conductor connection)Test passed

Product Description

Distribution floor terminal block, nominal voltage: 400 V, nominal current: 24 A, Screw connection, 1., 2. and 3rd floor, Dimensioning cross-section: 4 mm², cross-section: 0.2 mm² - 4 mm², mounting cl
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide