Service time: Monday to Friday 9:00-18:00
UT 4-QUATTRO HV BU - UT 4-QUATTRO HV BU 3048836 PHOENIX CONTACT Four-conductor universal terminal block
In Stock Hot Product

UT 4-QUATTRO HV BU

UT 4-QUATTRO HV BU 3048836 PHOENIX CONTACT Four-conductor universal terminal block

$2.33USD
4338 in stock
Key Specifications
:3047109 DS-UT 2,5/4
Color:blue (RAL 5015)
Width:6.2 mm
Height:65.4 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
3047109 DS-UT 2,5/4
Colorblue (RAL 5015)
Width6.2 mm
Height65.4 mm
ResultTest passed
output(Permanent)
SpectrumService life test category 2, bogie-mounted
ASD level6.12 (m/s²)²/Hz
Frequencyf1= 5 Hz to f2= 250 Hz
Potentials1
Bridge data27 A / 4 mm²
Pulse shapeHalf-sine
Revolutions135
Acceleration3.12g
Product typeMulti-conductor terminal block
Screw threadM3
Torque range0.6 Nm ... 0.8 Nm
Mounting typeNS 35/7,5
Rated current27 A
Rated voltage550 V
SpecificationDIN EN 50155 (VDE 0115-200):2018-05
Identification II 2 GD Ex eb IIC Gb
Number of rows1
Rotation speed10 (+/- 2) rpm
Shock duration18 ms
End cover width2.2 mm
List of bridgesPlug-in bridge / FBS 2-6 / 3030336
Nominal current32 A (with 4 mm² conductor cross section)
Nominal voltage1000 V
Open side panelYes
Test directionsX-, Y- and Z-axis
Article revision07
Stripping length9 mm
Time of exposure30 s
Cross section AWG26 ... 10 (converted acc. to IEC)
Tightening torque0.6 ... 0.8 Nm
Contact resistance0.6 mΩ
Depth on NS 35/1557.5 mm
Degree of pollution3
Depth on NS 35/7,550 mm
Insulating materialPA
Rated surge voltage6 kV
Test force setpoint1 N
Maximum load current37 A (In the case of a 6 mm² conductor cross section, the maximum load current must not be exceeded by the total current of all connected conductors)
Overvoltage categoryIII
Nominal cross section4 mm²
Number of connections4
Test voltage setpoint9.8 kV
Test duration per axis5 h
Connection capacity AWG26 ... 10
DIN rail/fixing supportNS 32/NS 35
Ex temperature increase40 K (27 A / 4 mm²)
Rated cross section AWG12
Ex-certified accessories3048852 D-UT 4-QUATTRO HV
Rated insulation voltage500 V
for bridging with bridge550 V
Connection capacity rigid0.14 mm² ... 6 mm²
Insulating material groupI
Internal cylindrical gageA4
Operating temperature range-60 °C ... 110 °C
Connection capacity flexible0.14 mm² ... 6 mm²
Conductor cross section rigid0.14 mm² ... 6 mm²
Ambient temperature (assembly)-5 °C ... 70 °C
Conductor cross section/weight0.14 mm² / 0.2 kg
Number of shocks per direction3
Ambient temperature (actuation)-5 °C ... 70 °C
Ambient temperature (operation)-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Number of connections per level4
Conductor cross section flexible0.14 mm² ... 6 mm²
Connection in acc. with standardIEC 60947-7-1
Permissible humidity (operation)20 % ... 90 %
Requirement temperature-rise testIncrease in temperature ≤ 45 K
Short-time withstand current 4 mm²0.48 kA
Short-time withstand current 6 mm²0.72 kA
Flammability rating according to UL 94V0
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C)
Conductor cross section, flexible [AWG]26 ... 10 (converted acc. to IEC)
Permissible humidity (storage/transport)30 % ... 70 %
Surface flammability NFPA 130 (ASTM E 162)passed
2 conductors with same cross section, solid0.14 mm² ... 1.5 mm²
2 conductors with same cross section, flexible0.14 mm² ... 1.5 mm²
2 conductors with same cross section, stranded0.14 mm² ... 1.5 mm²
Static insulating material application in cold-60 °C
Maximum power dissipation for nominal condition1.02 W
- At bridging between non-adjacent terminal blocks352 V
2 conductors with the same cross-section AWG rigid26 ... 16
2 conductors with the same cross-section AWG flexible26 ... 16
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Flexible conductor cross section (ferrule with plastic sleeve)0.14 mm² ... 4 mm²
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Conductor cross-section flexible (ferrule without plastic sleeve)0.14 mm² ... 4 mm²
2 conductors with same cross section, flexible, with ferrule without plastic sleeve0.25 mm² ... 1.5 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve0.5 mm² ... 1.5 mm²

Product Description

Four-conductor universal terminal block, nominal voltage: 1000 V, nominal current: 32 A, number of connections: 4, connection type: Screw connection, 1st floor, Dimensioning cross-section: 4 mm², cros
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top