Service time: Monday to Friday 9:00-18:00
UT 4-PE/L/HESILED 60 (5X20) - UT 4-PE/L/HESILED 60 (5X20) 3214322 PHOENIX CONTACT Fuse modular terminal block
In Stock Hot Product

UT 4-PE/L/HESILED 60 (5X20)

UT 4-PE/L/HESILED 60 (5X20) 3214322 PHOENIX CONTACT Fuse modular terminal block

$0.00USD
3028 in stock
Key Specifications
:max. 1.6 W (With interconnected arrangement of several fuse terminal blocks in the event of overload)
Fuse:G / 5 x 20
Note:Please observe the current carrying capacity of the DIN rails.
Color:black (RAL 9005)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
max. 1.6 W (With interconnected arrangement of several fuse terminal blocks in the event of overload)
FuseG / 5 x 20
NotePlease observe the current carrying capacity of the DIN rails.
Colorblack (RAL 9005)
Depth94.5 mm
Width6.2 mm
Height92.7 mm
output(Permanent)
GeneralThe current is determined by the fuse used, the voltage by the selected LED.If the fuse is faulty, the downstream circuit will not be disconnected.
Fuse typeGlass / ceramics / ...
Potentials3
Product typeGround terminal block
Screw threadM3
Torque range0.6 Nm ... 0.8 Nm
Mounting typeNS 35/7,5
Rated current20 A (4 mm²)
Rated voltage500 V
Grounding footYes
Identification II 3 G Ex ec llC Gc
Number of rows3
Nominal current28 A
Nominal voltage60 V
Open side panelNo
Article revision14
Stripping length9 mm
Cross section AWG26 ... 10 (converted acc. to IEC)
LED current range0.4 mA ... 0.86 mA
LED voltage range30 V AC ... 60 V AC
Tightening torque0.6 ... 0.8 Nm
Contact resistance0.6 mΩ
Depth on NS 35/1596.4 mm
Degree of pollution3
Depth on NS 35/7,588.9 mm
Insulating materialPA
Rated surge voltage6 kV
Maximum load current36 A (the current is determined by the fuse used)
Overvoltage categoryIII
Temperature increase40 K (20 A/4 mm²)
Nominal cross section4 mm²
Number of connections5
Connection capacity AWG26 ... 10
Rated cross section AWG12
Ex-certified accessories1205053 SZS 0,6X3,5
Connection capacity rigid0.14 mm² ... 6 mm²
Insulating material groupI
Internal cylindrical gageA4
Maximum power dissipationmax. 1.6 W (with single arrangement of the fuse terminal block in the event of overload)
Operating temperature range-60 °C ... 130 °C
Connection capacity flexible0.14 mm² ... 6 mm²
Conductor cross section rigid0.14 mm² ... 6 mm²
Ambient temperature (assembly)-5 °C ... 70 °C
Ambient temperature (actuation)-5 °C ... 70 °C
Ambient temperature (operation)-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Number of connections per level2
Conductor cross section flexible0.14 mm² ... 6 mm²
Connection in acc. with standardIEC 60947-7-2/IEC 60947-7-3
Permissible humidity (operation)20 % ... 90 %
Flammability rating according to UL 94V0
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Conductor cross section, flexible [AWG]26 ... 10 (converted acc. to IEC)
Permissible humidity (storage/transport)30 % ... 70 %
Surface flammability NFPA 130 (ASTM E 162)passed
2 conductors with same cross section, solid0.14 mm² ... 1.5 mm²
2 conductors with same cross section, stranded0.14 mm² ... 1.5 mm²
Static insulating material application in cold-60 °C
Maximum power dissipation for nominal condition1.02 W
Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg
2 conductors with the same cross-section AWG rigid26 ... 16
2 conductors with the same cross-section AWG flexible26 ... 16
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Flexible conductor cross section (ferrule with plastic sleeve)0.14 mm² ... 4 mm²
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Conductor cross-section flexible (ferrule without plastic sleeve)0.14 mm² ... 4 mm²
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C
Conductor cross section flexible, with ferrule without plastic sleeve max.4 mm²
Conductor cross section flexible, with ferrule without plastic sleeve min.0.14 mm²
Single conductor/terminal point, flexible, with ferrule, without plastic sleeve, AWG26 ... 12

Product Description

Fuse rail terminal, fuse type: Glass/ceramic/..., fuse type: G/5 x 20, nominal voltage: 60 V, nominal current: 28 A, connection type: Screw connection, Sizing section: 4 mm², cross-section: 0.14 mm²-
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top