Service time: Monday to Friday 9:00-18:00
UT 4-HESILED 24-P/P-EX - UT 4-HESILED 24-P/P-EX 1021489 PHOENIX CONTACT Rail terminal for fuse, with threaded females for test socket..
In Stock Hot Product

UT 4-HESILED 24-P/P-EX

UT 4-HESILED 24-P/P-EX 1021489 PHOENIX CONTACT Rail terminal for fuse, with threaded females for test socket..

$9.72USD
1067 in stock
Key Specifications
:max. 1.6 W (for combined arrangement with several fuse terminals in case of overload)
Fuse:G/5 x 20
Colour:black
Marked: II 3 G Ex ec llC Gc
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
max. 1.6 W (for combined arrangement with several fuse terminals in case of overload)
FuseG/5 x 20
Colourblack
Marked II 3 G Ex ec llC Gc
Fuse TypeGlass/ceramics/...
Potential1
Male GaugeA4
analogical(permanent)
Product TypeFuse terminal block
Screw threadM3
Torque range0.6 Nm ... 0.8 Nm
Open sidewallNo
Rated Current6.3 A (4 mm²)
Number of rows1
Surge CategoryIii
Nominal Section4 mm²
Nominal voltage275 V
Number of poles1
Type of mountingNS 35/7.5
Tightening torque0,6 ... 0.8 Nm
AWG Sizing Section12
Contact resistance5 mΩ
Degree of pollution3
Insulating materialPA
Maximum dissipationmax. 1.6 W (for individual arrangement of the fuse terminal block in case of overload)
AWG Conductor Section(Converted according to IEC)
Number of connections2
Rigid conductor section0.14 mm² ... 6 mm²
Current Light Indication6.3 A
Ex-certified accessories1205053 SZS 0.6X3.5
Maximum Charging Current6.3 A (6 mm²)
AWG Connection Capability26 ... 10
Insulating material groupI
Length to be de-insulated9 mm
Sizing Insulation Voltage250 V
Flexible conductor section0.14 mm² ... 6 mm²
Connectability, Rigid Cable0.14 mm² ... 6 mm²
Flexible Wire Section [AWG]26 ... 10 (Converted according to IEC)
Operating temperature range-60 °C ... 130 °C
Connectability, flexible cable0.14 mm² ... 6 mm²
Current Range Light Indication0.31 mA ... 0.95 mA
Dimensioning Transient Voltage4 kV
Voltage Range Light Indication12 V AC/DC ... 30 V AC/DC
Number of connections per floor2
Flammability class according to UL 94V0
2 conductors with the same cross-section, rigid0.14 mm² ... 1.5 mm²
Maximum Dissipated Power with Nominal Condition1.02 W
Maximum current in case of individual arrangement6.3 A
2 conductors with the same cross-section, flexible0.14 mm² ... 1.5 mm²
2 conductors with the same rigid AWG cross-section26 ... 16
Flexible cable section (toe cap with plastic sleeve)0.14 mm² ... 4 mm²
2 conductors with the same flexible AWG cross-section26 ... 16
Flexible cable section (toe cap without plastic sleeve)0.14 mm² ... 4 mm²
Flexible driver/terminal point with AWG plastic sleeveless ferrule26 ... 12
Flexible conductor section with toe cap, without min plastic sleeve.0.14 mm²
Flexible conductor section with toe cap, without plastic sleeve max.4 mm²

Product Description

Fuse rail terminal, with threaded sockets for test sockets to accommodate test pins, fuse type: Glass/ceramic/..., fuse type: G/5 x 20, number of poles: 1, connection type: Screw connection, Dimension
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top