Service time: Monday to Friday 9:00-18:00
UT 2,5-PE/L/L - UT 2,5-PE/L/L 3214301 PHOENIX CONTACT Ground modular terminal block
In Stock Hot Product

UT 2,5-PE/L/L

UT 2,5-PE/L/L 3214301 PHOENIX CONTACT Ground modular terminal block

$7.35USD
1407 in stock
Key Specifications
GTIN:4046356575454
Orderkey:3214301
Catalog page:Page 220 (C-1-2017)
Packing unit:50 pc
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356575454
Orderkey3214301
Catalog pagePage 220 (C-1-2017)
Packing unit50 pc
Width (General)5.2 mm
Length (General)90 mm
Country of originPL (Poland)
Note (Dimensions)Please observe the current carrying capacity of the DIN rails.
(Connection data)IEC 60947-7-1/IEC 60947-7-2
Custom tariff number85369010
Height NS 35/15 (General)85 mm
Screw thread (Dimensions)M3
Height NS 35/7,5 (General)77.5 mm
Color (Key Commercial Data)gray
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Stripping length (Dimensions)9 mm
Connection method (Dimensions)Screw connection
Tightening torque max (Dimensions)0.6 Nm
Tightening torque, min (Dimensions)0.5 Nm
Weight per Piece (excluding packing)29.030 g
Open side panel (Key Commercial Data)Yes
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Internal cylindrical gage (Dimensions)A3
Number of levels (Key Commercial Data)3
Nominal current IN (Key Commercial Data)19 A (with a 2.5 mm² conductor cross section)
Nominal voltage UN (Key Commercial Data)500 V
Degree of pollution (Key Commercial Data)3
Insulating material (Key Commercial Data)PA
Rated surge voltage (Key Commercial Data)6 kV
Maximum load current (Key Commercial Data)24 A (with 4 mm² conductor cross section)
Overvoltage category (Key Commercial Data)III
Nominal cross section (Key Commercial Data)2.5 mm²
Number of connections (Key Commercial Data)6
Conductor cross section AWG max. (Dimensions)12
Conductor cross section AWG min. (Dimensions)26
Conductor cross section solid max. (Dimensions)4 mm²
Conductor cross section solid min. (Dimensions)0.14 mm²
Insulating material group (Key Commercial Data)I
Conductor cross section flexible max. (Dimensions)4 mm²
Conductor cross section flexible min. (Dimensions)0.14 mm²
Connection in acc. with standard (Connection data)CSA
NF F16-101, NF F10-102 Class F (Key Commercial Data)2
NF F16-101, NF F10-102 Class I (Key Commercial Data)2
Connection in acc. with standard (Key Commercial Data)IEC 60947-7-1/IEC 60947-7-2
Oxygen index (DIN EN ISO 4589-2) (Key Commercial Data)>32 %
Flammability rating according to UL 94 (Connection data)V0
Flame test method (DIN EN 60695-11-10) (Key Commercial Data)V0
Flammability rating according to UL 94 (Key Commercial Data)V0
Smoke gas toxicity NFPA 130 (SMP 800C) (Key Commercial Data)passed
Surface flammability NFPA 130 (ASTM E 162) (Key Commercial Data)passed
Static insulating material application in cold (Key Commercial Data)-60 °C
Behavior in fire for rail vehicles (DIN 5510-2) (Key Commercial Data)Test passed
Maximum power dissipation for nominal condition (Key Commercial Data)0.77 W (the value is multiplied when connecting multiple levels)
Calorimetric heat release NFPA 130 (ASTM E 1354) (Key Commercial Data)28 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Connection data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Connection data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Connection data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 (Connection data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Key Commercial Data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Key Commercial Data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Key Commercial Data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 (Key Commercial Data)HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662) (Key Commercial Data)passed
Conductor cross section flexible, with ferrule with plastic sleeve max. (Dimensions)2.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min. (Dimensions)0.14 mm²
Relative insulation material temperature index (Elec.; UL 746 B) (Key Commercial Data)130 °C
Conductor cross section flexible, with ferrule without plastic sleeve max. (Dimensions)2.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve min. (Dimensions)0.14 mm²
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) (Key Commercial Data)130 °C

Product Description

Ground terminal, nominal voltage: 500 V, nominal current: 19 A, connection type: Screw connection, 1., 2. and 3rd floor, Sizing cross-section: 2.5 mm², cross-section: 0.14 mm² - 4 mm², mounting class:
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top