Service time: Monday to Friday 9:00-18:00
UST4C11 - UST4C11 ST4-C11 PANASONIC Controller for ST4
In Stock Hot Product

UST4C11

UST4C11 ST4-C11 PANASONIC Controller for ST4

$0.00USD
3452 in stock
Key Specifications
Item:Specifications
PFHD:Refer to the following table(Note: (Probability of dangerous failure per hour) depends on number of single beam sensorST4-A□connected to controller.)
MTTFD:More than 100 years (Note:Mean time to dangerous failure (in years))
Weight:Net weight: 180 g approxGross weight: 390 g approx
Supplier Information
PANASONIC
PANASONIC
Products: 4316
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
ItemSpecifications
PFHDRefer to the following table(Note: (Probability of dangerous failure per hour) depends on number of single beam sensorST4-A□connected to controller.)
MTTFDMore than 100 years (Note:Mean time to dangerous failure (in years))
WeightNet weight: 180 g approxGross weight: 390 g approx
DetailsController
ProductCompact Type 4 Safety Beam Sensor
MaterialEnclosure: ABS
Part NumberST4-C11
Product nameCompact Type 4 Safety Beam Sensor ST4
Wiring cableTerminal block connector: 0.2 to 1.5 mm2
Power voltage24 V DC +10-15 % Ripple P-P 10 % or less
Response timeOFF response: 25 ms or lessON response: 90 ms or less (auto reset) / 140 ms or less (manual reset)
Product NumberST4-C11
Auxiliary outputsPNP open-collector transistor / NPN open-collector transistor (Set using output polarity selection switch)ST4-C11: one outputST4-C12EX: four outputs[PNP output]Maximum source current: 100 mAApplied voltage: same as the supply voltage (between auxiliary output and +V)Residual voltage: 2.5 V or less (at 100 mA source current)[NPN output]Maximum sink current: 100 mAApplied voltage: same as the supply voltage (between auxiliary output and 0 V)Residual voltage: 2.0 V or less (at 100 mA sink current)(Note) If the total current of the control outputs (OSSD1, OSSD2), auxiliary outputs, and muting lamp output exceeds 400 mA, the wiring resistance between the controller and the power supply should be 1 Ohm or less. In addition, if the total current is 400 mA or less, the wiring resistance between the controller and the power supply should be 2 Ohm or less.
Muting lamp output-(Note) If the total current of the control outputs (OSSD1, OSSD2), auxiliary outputs, and muting lamp output exceeds 400 mA, the wiring resistance between the controller and the power supply should be 1 Ohm or less. In addition, if the total current is 400 mA or less, the wiring resistance between the controller and the power supply should be 2 Ohm or less.
Connection terminalDetachable spring-cage terminal
Current consumption100 mA or less (excluding sensor head ST4-Ax)
Applicable standardsIEC 61496-1/2 (JIS B 9704-1/2 / UL 61496-1/2) (Type 4), ISO 13849-1:2015 (Category 4, PLe), JIS B 9705-1 (Category 4), IEC 61508-1 to 3 (SIL3), IEC 62061 (SIL3), JIS C 0508-1 to 3 (SIL3), UL 1998, OSHA 1910.212, OSHA 1910.217 (C), ANSI B11.1 to B11.19, ANSI/RIA R15.06, ANSI/ISA S84.01 (SIL3)(Note) Complies with those standards only when the controller is used in combination with the sensor head ST4-x.
Applicable sensor headST4-Ax
CE marking directive complianceMachinery Directive, EMC Directive, RoHS Directive
Auxiliary outputs:Operation modeOFF when all beams of the connected ST4-Axs are receivedON when one or more beams of the connected ST4-Axs are interrupted
Control outputs (OSSD 1, OSSD 2)PNP open-collector transistor / NPN open-collector transistor Dual output x 1 system (Set using output polarity selection switch)[PNP output]Maximum source current: 200 mAApplied voltage: same as the supply voltage (between control output and +V)Residual voltage: 2.5 V or less (at 200 mA source current)Leakage current: 200 micro A or less (including power OFF condition)Maximum load capacity: 1 micro F (from no-load to max. source current)Load wiring resistance: 3 Ohm or less (between control output and load)[NPN output]Maximum sink current: 200 mAApplied voltage: same as the supply voltage (between control output and 0 V)Residual voltage: 2.0 V or less (at 200 mA sink current)Leakage current: 200 micro A or less (including power OFF condition)Maximum load capacity: 1 micro F (from no-load to max. sink current)Load wiring resistance: 3 Ohm or less (between control output and load)(Note) If the total current of the control outputs (OSSD1, OSSD2), auxiliary outputs, and muting lamp output exceeds 400 mA, the wiring resistance between the controller and the power supply should be 1 Ohm or less. In addition, if the total current is 400 mA or less, the wiring resistance between the controller and the power supply should be 2 Ohm or less.
Auxiliary outputs:Protection circuitIncorporated
Muting lamp output:Protection circuitIncorporated
Environmental resistance:Ambient humidity30 to 85 % RH, Storage: 30 to 95 % RH
Environmental resistance:Shock resistance300 m/s2acceleration in X, Y and Z directions three times each
Environmental resistance:Ambient temperature-10 to +55 ℃+14 to +131℉(No dew condensation or icing allowed),Storage: -25 to +70 ℃-13 to +158℉
Environmental resistance:Degree of protectionEnclosure: IP40 (IEC)Terminal: IP20 (IEC)
Environmental resistance:Vibration resistance10 to 55 Hz frequency, 0.75 mm0.030 indouble amplitude or maximum acceleration 90 m/s2 in X, Y and Z directions for two hours each<
Environmental resistance:Insulation resistance20 MOhm or more with 500 V DC mega between all supply terminals connected together and enclosure
Control outputs (OSSD 1, OSSD 2):Operation modeON when all beams of the connected ST4-Axs are receivedOFF when one or more beams of the connected ST4-Axs are interruptedOFF during lockout
Applicable sensor head:No. of series connectionsInterference prevention possible when up to a maximum of 6 sets are connected(When the maximum of 3 controllers are connected together, interference prevention is possible for up to 18 sets)
Control outputs(OSSD1, OSSD2):Protection circuitIncorporated
Environmental resistance:Voltage withstandability1,000 V AC for one min. between all supply terminals connected together and enclosure

Product Description

Standard Control Unit Safety Barrier Category 4 Ple SIL 3, ST4 Series
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top