Service time: Monday to Friday 9:00-18:00
USGB1SAG1 - USGB1SAG1 SG-B1-SA-G1 PANASONIC Safety door switch (Ultra-slim) with solenoid interlock, Spring lock, 1m cab..
In Stock Hot Product

USGB1SAG1

USGB1SAG1 SG-B1-SA-G1 PANASONIC Safety door switch (Ultra-slim) with solenoid interlock, Spring lock, 1m cab..

$0.00USD
3196 in stock
Key Specifications
:Ue
DC:Resistive load (DC-12)
Ie:Main circuit, look monitor circuit
B10D:2,000,000(ISO 13849-1 Annex C Table C.1)
Supplier Information
PANASONIC
PANASONIC
Products: 4316
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Ue
DCResistive load (DC-12)
IeMain circuit, look monitor circuit
B10D2,000,000(ISO 13849-1 Annex C Table C.1)
ItemSpecifications
CableUL style 2464, No.22 AWG 12-core
WeightApprox. 220 g
DetailsSpring lock type
ProductUltra-slim Safety door switch with solenoid interlock
MaterialEnclosure : PA66
ProtectionIP 67 (IEC 60529)
Part NumberSG-B1-SA-G1
Cable length1m3.281 ft
Product nameUltra-slim Safety door switch with solenoid interlock SG-B1
Main contacts1NC + 1NC
Product NumberSG-B1-SA-G1
Interlock force500 N min. (GS-ET-19)(Note): The actuator locking strength is rated at 500 N of static load. Do not apply a load higher than the rated value.Do not apply a load higher than the rated value.When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine.
Shock resistanceMalfunction : 100 m/s2, Destruction : 1,000 m/s2
Contact resistance300 mΩ max. (initial value, 1 m3.281 ftcable)700 mΩ max. (initial value, 5 m16.404 ftcable)
Operating frequency900 operations/hour
Applicable standardsEN 60947-5-1, GS-ET-19
Direct opening force60 N min.
Door monitor circuitAC
Vibration resistanceMalfunction : 10 to 55 Hz, half amplitude 0.35 mm0.014 inDestruction : 30 Hz, half amplitude 1.5 mm0.059 in
Direct opening travel8 mm0.315 inmin.
Door monitor contacts2NC
Electrical durability100,000 operations min.(900 operations/hour,AC-12 125 V 2A, DC-12 125 V 0.4 A)1,000,000 operations min.(900 operations/hour,24 V AC/DC 0.1 A resistive load)
Lock monitor contacts1NC
Mechanical durability1,000,000 operations min. (GS-ET-19)
Thermal current (Ith)・Ambient temperature : -25 to +35 ℃-13 to +95 ℉2.5 A (up to 2 circuits)1.0 A (3 or more circuits)・Ambient temperature : 35 to +50 ℃95 to +122 ℉1.0 A (1 circuit)0.5 A (2 or more circuits)
Applicable regulationsCE Marking [Machinery Directive (2006/42/EC), RoHS Directive], UKCA Marking [Supply of Machinery (Safety) Regulations (2008 No.1597), RoHS Regulations]
Inductive load (AC-15)-
Inductive load (DC-13)1A
Actuator operating speed0.05 to 1.0 m/sec.
Rated insulation voltage (Ui)300 V (Door monitor circuit)150 V (Main, Lock monitor circuit)30 V (Between ground and LED, solenoid circuit)
Operating condition : Altitude2,000 m6,561.68 ftmax.
Electric shock protection classClass II (IEC 61140)(Note), 回(double insulated)(Note): Basic insulation of 2.5 kV, 1.5 kV impulse withstand voltage is ensured between different contact circuits and between contact circuits and LED or solenoid in the enclosure. When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more.
Short-circuit protective deviceUse 250 V / 10 A fast acting type fuse
Impulse withstand voltage (Uimp)2.5 kV (Door monitor circuit)1.5 kV (Main, Lock monitor circuit)0.5 kV (Between ground and LED, solenoid circuit)
Solenoid / Indicator : IndicatorGreen LED
Solenoid / Indicator : Rated current110 mA (solenoid 100 mA, LED 10 mA : initial value)
Operating condition : Ambient humidity45 to 85 % RH
Operating condition : Pollution degree3 (Inside 2)
Solenoid / Indicator : Turn on voltageRated voltage × 85 % max. (at 20 ℃68 ℉)
Solenoid / Indicator : Turn off voltageRated voltage × 10 % min. (at 20 ℃68 ℉)
Applicable standards : Standards for useIEC 60204-1 / EN 60204-1, ISO 14119, EN ISO 14119, IEC 60947-5-1, UL 508, CSA C22.2 No.14
Operating condition : Ambient temperature-25 to +50 ℃-13 to +122 ℉(No dew condensation or icing allowed)Storage : -40 to +80 ℃-40 to +176 ℉
Solenoid / Indicator : Rated operating voltageDC 24 V 100% duty cycle
Rated operational voltage (Ue) / Rated operational current (Ie)Ue30V125V250VIeMain circuit, look monitor circuitACResistive load (AC-12)-2A-Inductive load (AC-15)-1A-DCResistive load (DC-12)2A0.4A-Inductive load (DC-13)1A0.22A-Door monitor circuitACResistive load (AC-12)-2.5A1.5AInductive load (AC-15)-1.5A0.75ADCResistive load (DC-12)2.5A1.1A0.55AInductive load (DC-13)2.3A0.55A0.27A

Product Description

Safety limit switch (Ultra-narrow) for door with magnetic interconnection, spring lock, 1m cable, main 1NC+1NC, Monitor 2NC+1NC
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top