| Parameter | Value |
|---|---|
| Ue | |
| DC | Resistive load (DC-12) |
| Ie | Main circuit, look monitor circuit |
| B10D | 2,000,000(ISO 13849-1 Annex C Table C.1) |
| Item | Specifications |
| Cable | UL style 2464, No.22 AWG 12-core |
| Weight | Approx. 600 g |
| Details | Magnet lock type |
| Product | Ultra-slim Safety door switch with solenoid interlock |
| Material | Enclosure : PA66 |
| Protection | IP 67 (IEC 60529) |
| Part Number | SG-B1-MB-G5 |
| Cable length | 5m16.404 ft |
| Product name | Ultra-slim Safety door switch with solenoid interlock SG-B1 |
| Main contacts | 1NC + 1NC |
| Product Number | SG-B1-MB-G5 |
| Interlock force | 500 N min. (GS-ET-19)(Note): The actuator locking strength is rated at 500 N of static load. Do not apply a load higher than the rated value.Do not apply a load higher than the rated value.When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine. |
| Shock resistance | Malfunction : 100 m/s2, Destruction : 1,000 m/s2 |
| Contact resistance | 300 mΩ max. (initial value, 1 m3.281 ftcable)700 mΩ max. (initial value, 5 m16.404 ftcable) |
| Operating frequency | 900 operations/hour |
| Applicable standards | EN 60947-5-1, GS-ET-19 |
| Direct opening force | 60 N min. |
| Door monitor circuit | AC |
| Vibration resistance | Malfunction : 10 to 55 Hz, half amplitude 0.35 mm0.014 inDestruction : 30 Hz, half amplitude 1.5 mm0.059 in |
| Direct opening travel | 8 mm0.315 inmin. |
| Door monitor contacts | 2NC |
| Electrical durability | 100,000 operations min.(900 operations/hour,AC-12 125 V 2A, DC-12 125 V 0.4 A)1,000,000 operations min.(900 operations/hour,24 V AC/DC 0.1 A resistive load) |
| Lock monitor contacts | 1NO |
| Mechanical durability | 1,000,000 operations min. (GS-ET-19) |
| Thermal current (Ith) | ・Ambient temperature : -25 to +35 ℃-13 to +95 ℉2.5 A (up to 2 circuits)1.0 A (3 or more circuits)・Ambient temperature : 35 to +50 ℃95 to +122 ℉1.0 A (1 circuit)0.5 A (2 or more circuits) |
| Applicable regulations | CE Marking [Machinery Directive (2006/42/EC), RoHS Directive], UKCA Marking [Supply of Machinery (Safety) Regulations (2008 No.1597), RoHS Regulations] |
| Inductive load (AC-15) | - |
| Inductive load (DC-13) | 1A |
| Actuator operating speed | 0.05 to 1.0 m/sec. |
| Rated insulation voltage (Ui) | 300 V (Door monitor circuit)150 V (Main, Lock monitor circuit)30 V (Between ground and LED, solenoid circuit) |
| Operating condition : Altitude | 2,000 m6,561.68 ftmax. |
| Electric shock protection class | Class II (IEC 61140)(Note), 回(double insulated)(Note): Basic insulation of 2.5 kV, 1.5 kV impulse withstand voltage is ensured between different contact circuits and between contact circuits and LED or solenoid in the enclosure. When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more. |
| Short-circuit protective device | Use 250 V / 10 A fast acting type fuse |
| Impulse withstand voltage (Uimp) | 2.5 kV (Door monitor circuit)1.5 kV (Main, Lock monitor circuit)0.5 kV (Between ground and LED, solenoid circuit) |
| Solenoid / Indicator : Indicator | Green LED |
| Solenoid / Indicator : Rated current | 110 mA (solenoid 100 mA, LED 10 mA : initial value) |
| Operating condition : Ambient humidity | 45 to 85 % RH |
| Operating condition : Pollution degree | 3 (Inside 2) |
| Solenoid / Indicator : Turn on voltage | Rated voltage × 85 % max. (at 20 ℃68 ℉) |
| Solenoid / Indicator : Turn off voltage | Rated voltage × 10 % min. (at 20 ℃68 ℉) |
| Applicable standards : Standards for use | IEC 60204-1 / EN 60204-1, ISO 14119, EN ISO 14119, IEC 60947-5-1, UL 508, CSA C22.2 No.14 |
| Operating condition : Ambient temperature | -25 to +50 ℃-13 to +122 ℉(No dew condensation or icing allowed)Storage : -40 to +80 ℃-40 to +176 ℉ |
| Solenoid / Indicator : Rated operating voltage | DC 24 V 100% duty cycle |
| Rated operational voltage (Ue) / Rated operational current (Ie) | Ue30V125V250VIeMain circuit, look monitor circuitACResistive load (AC-12)-2A-Inductive load (AC-15)-1A-DCResistive load (DC-12)2A0.4A-Inductive load (DC-13)1A0.22A-Door monitor circuitACResistive load (AC-12)-2.5A1.5AInductive load (AC-15)-1.5A0.75ADCResistive load (DC-12)2.5A1.1A0.55AInductive load (DC-13)2.3A0.55A0.27A |
Technical specifications and performance data