| Parameter | Value |
|---|---|
| Ue | |
| DC | Resistive load (DC-12) |
| Ie | AC |
| B10D | 2,000,000(ISO 13849-1 Annex C Table C.1) |
| Item | Specifications |
| Cable | UL style 2464, No.20 AWG 6-core |
| Weight | Approx. 120 g |
| Product | Ultra-slim Safety door switch |
| Material | Enclosure : PA66 |
| Protection | IP 67 (IEC 60529) |
| Part Number | SG-A1-03-1 |
| Cable length | 1 m3.281 ft |
| Product name | Ultra-slim Safety door switch SG-A1 |
| Product Number | SG-A1-03-1 |
| Shock resistance | Malfunction : 300 m/s2Destruction : 1,000 m/s2 |
| Contact resistance | 300 mΩ max. (initial value, 1 m3.281 ftcable)700 mΩ max. (initial value, 5 m16.404 ftcable) |
| Operating frequency | 1,200 operations/hour |
| Applicable standards | EN 60947-5-1, GS-ET-15 |
| Direct opening force | 60 N min. |
| Vibration resistance | Malfunction : 5 to 55 Hz, half amplitude 0.5 mm0.020 inDestruction : 30 Hz, half amplitude 1.5 mm0.059 in |
| Direct opening travel | 8 mm0.315 inmin. |
| Door monitor contacts | 3NC |
| Electrical durability | 100,000 operations min. (AC-12, 250 V 1.5 A, DC-12 250 V 0.2 A)1,000,000 operations min. (AC/DC 24 V 100 mA)(1,200 operations/hour) |
| Mechanical durability | 1,000,000 operations min. (GS-ET-15) |
| Thermal current (Ith) | 2.5 A |
| Applicable regulations | CE Marking [Machinery Directive (2006/42/EC), RoHS Directive], UKCA Marking [Supply of Machinery (Safety) Regulations (2008 No.1597), RoHS Regulations] |
| Inductive load (AC-15) | - |
| Inductive load (DC-13) | 2.3A |
| Actuator operating speed | 0.05 to 1.0 m/sec. |
| Rated insulation voltage (Ui) | 300 V |
| Operating condition : Altitude | 2,000 m6,561.68 ftmax. |
| Electric shock protection class | Class II (IEC 61140), 回(double insulated) |
| Short-circuit protective device | Use 250 V / 10 A fast acting type fuse |
| Impulse withstand voltage (Uimp) | 4 kV |
| Conditional short-circuit current | 50 A (250 V) |
| Operating condition : Ambient humidity | 45 to 85 % RH |
| Operating condition : Pollution degree | 3 (Inside 2) |
| Applicable standards : Standards for use | IEC 60204-1 / EN 60204-1, ISO 14119, EN ISO14119, IEC 60947-5-1, UL 508, CSA C22.2 No.14 |
| Operating condition : Ambient temperature | -25 to +70 ℃-13 to +158 ℉(No dew condensation or icing allowed)Storage : -40 to +80 ℃-40 to +176 ℉ |
| Rated operational voltage (Ue) / Rated operational current (Ie) | Ue30V125V250VIeACResistive load (AC-12)-2.5A1.5AInductive load (AC-15)-1.5A0.75ADCResistive load (DC-12)2.5A1.1A0.55AInductive load (DC-13)2.3A0.55A0.27A |
Technical specifications and performance data
Installation and operation guide