Service time: Monday to Friday 9:00-18:00
USFC13 - USFC13 SFC13 SF-C13 PANASONIC Control unit for SF4B, thin type
In Stock Hot Product

USFC13

USFC13 SFC13 SF-C13 PANASONIC Control unit for SF4B, thin type

$0.00USD
4928 in stock
Key Specifications
Item:Specifications
Weight:Net weight: 200 g approx.
Details:Slim type control unit
Product:Exclusive Control Unit for Safety Light Curtain
Supplier Information
PANASONIC
PANASONIC
Products: 4316
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
ItemSpecifications
WeightNet weight: 200 g approx.
DetailsSlim type control unit
ProductExclusive Control Unit for Safety Light Curtain
Fuse ratingBuilt-in electronic fuse, Triggering current: 0.5 A or more, Reset after power down
Part NumberSF-C13
Product nameExclusive Control Unit for Safety Light Curtain SF-C10
Power voltage24 V DC ±10 % Ripple P-P 10 % or less / 100 mA or less (without safety light curtain)
Response time10 ms or less
Safety outputNO contact × 3 (13-14, 23-24, 33-34)
Product NumberSF-C13
Ambient humidity30 to 85 % RH, Storage: 30 to 95 % RH
Pollution degree2
Auxiliary outputsSafety relay contact (NC contact) × 1 (41-42) (Related to enabling path)
Enclosure materialABS
Ambient temperature-10 to +55 ℃+14 to +131℉(No dew condensation or icing allowed),Storage: -25 to +70 ℃-13 to +158℉
Connection terminalSpring-cage terminal
Current consumption100 mA or less (without light curtain)
Overvoltage categoryII
Vibration resistanceResistance / malfunction 10 to 55 Hz frequency, 0.35 mm0.014 inamplitudein X, Y, and Z directions for twenty times each
Trailing edge functionIncorporated
Indicators:Fault (FAULT)Yellow LED (blinks when fault occurs)
Applicable standards:JapanJIS B 9704-1 (Type 4), JIS B 9705-1(Category 4),
Polarity selection functionIncorporated (Cable connection allows selection of plus/minus ground)Minus ground: Correspond to PNP output safety light curtainPlus ground: Correspond to NPN output safety light curtain(Note:Please switch the sliding switch to the PNP side for minus ground and to the NPN side for plus ground.)
Indicators:Power supply (Ui)Green LED (lights up when the power is ON)
Indicators:Safety output [OUT]Green LED (lights up when safety output is closed)(Note:The operation indicator is marked as "Enabling" on the unit forSF-C12.)
CE marking directive complianceMachinery Directive, Low Voltage (SF-C11/C13 only) Directive, EMC Directive, RoHS Directive
External relay monitor functionIncorporated
Applicable standards:Europe (EU)EN 61496-1 (Type 4), EN 55011, EN ISO 13849-1 (Category 4, PLe), IEC 61496-1 (Type 4), ISO 13849-1 (Category 4, PLe)(Note:SF-C11andSF-C13comply with UL 1998 (Class 2).)
Safety output:Contact resistance100 mOhm or less (initial value)
Connectable safety light curtainsSafety light curtain manufactured by Panasonic Industrial Devices SUNX
Indicators:Interlock (INTER_LOCK)Yellow LED (lights up when enabling contacts are opened)
Safety output:Electrical lifetime100,000 times or more (open/close frequency of 20 times/min, 230 V AC, 3 A, using resistance load)(Note:The life expectancy of the relay varies depending on the type of load, open / close frequency, ambient conditions and others.)
Safety output:Mechanical lifetime10,000,000 times or more (open/close frequency of 180 times/min)(Note:The life expectancy of the relay varies depending on the type of load, open / close frequency, ambient conditions and others.)
Applicable standards:North AmericaANSI/UL 61496-1 (Type 4), UL 1998 (Class 2) (Note:SF-C11andSF-C13comply with UL 1998 (Class 2).)
Safety output:Application categoryAC-15, DC-13 (IEC 60947-5-1)
Semiconductor auxiliary output(AUX)PNP open-collector transistor・Max. source current: 60 mA・Applied voltage: same as supply voltage(between the semiconductorauxiliary output and +V)・Residual voltage: 2.3 V or less(at source current 60 mA)Leakage current: 2 mA or less
Pick-up delay(Auto reset / Manual reset)80 ms or less / 90 ms or less
Safety output:Contact material / contactsAgSnO, self cleaning, positively driven
Applicable standards:International standardIEC 61496-1 (Type 4)
Safety output:Contact protection fuse rated4 A (slow blow)
Environmental resistance:Degree of protectionEnclosure: IP40Terminal: IP20
Auxiliary output:Contact protection fuse rated2 A (slow blow)
Auxiliary output:Rated operation voltage / current24 V DC / 2 A, Min. applicable load: 10 mA (at 24 V DC)
Semiconductor auxiliary output(AUX):Output operationOn when the safety light curtain is interrupted
Safety output:Rated operation voltage (Ue) /Rated operation current (le)4 A / 30 V DC, 4 A / 230 V AC, resistive load (For inductive load, during contact protection) Min. applicable load: 10 mA (at 24 V DC)(Note:If severalSF-C11orSF-C13units are being used in a line together, leavea space of 5 mm0.197 inor more between each unit. If the units are touching each other, reduce the rated operating current for safety output in accordance with the ambient operating temperature as shown in the graphs below.)

Product Description

Narrow control unit for barriers and other safety products. Applicable to loose-wire terminated cables, control up to category 4
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top