Key Specifications
GTIN:4017918117122
Orderkey:0701024
Catalog page:Page 293 (CL-2005)
Packing unit:50 pc
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4017918117122
Orderkey0701024
Catalog pagePage 293 (CL-2005)
Packing unit50 pc
Width (General)8.2 mm
Length (General)43 mm
Country of originDE (Germany)
Custom tariff number85369010
(Key Commercial Data)HL 1 - HL 3
Height NS 32 (General)55.5 mm
Height NS 35/15 (General)58 mm
Screw thread (Dimensions)M4
Height NS 35/7,5 (General)50.5 mm
Color (Key Commercial Data)gray
(Standards and Regulations)No hazardous substances above threshold values
Stripping length (Dimensions)14 mm
Connection method (Dimensions)Screw connection
Setpoint (Key Commercial Data)5 N
Tightening torque max (Dimensions)1.8 Nm
Tightening torque, min (Dimensions)1.5 Nm
Weight per Piece (excluding packing)19.250 g
Open side panel (Key Commercial Data)Yes
China RoHS (Standards and Regulations)Environmentally friendly use period: unlimited = EFUP-e
Number of levels (Key Commercial Data)1
Bending test turns (Key Commercial Data)135
Nominal current IN (Key Commercial Data)57 A
Nominal voltage UN (Key Commercial Data)400 V
Short-time current (Key Commercial Data)1.2 kA
Degree of pollution (Key Commercial Data)3
Insulating material (Key Commercial Data)PA
Rated surge voltage (Key Commercial Data)6 kV
Tensile test result (Key Commercial Data)Test passed
Maximum load current (Key Commercial Data)57 A (with 10 mm² conductor cross section)
Overvoltage category (Key Commercial Data)III
Tight fit on carrier (Key Commercial Data)NS 35/NS 32
Number of connections (Key Commercial Data)2
Temperature-rise test (Key Commercial Data)Test passed
Result of bending test (Key Commercial Data)Test passed
Result of thermal test (Key Commercial Data)Test passed
Conductor cross section AWG max. (Dimensions)8
Conductor cross section AWG min. (Dimensions)20
Tractive force setpoint (Key Commercial Data)90 N
Conductor cross section solid max. (Dimensions)10 mm²
Conductor cross section solid min. (Dimensions)0.5 mm²
Insulating material group (Key Commercial Data)I
Requirements, voltage drop (Key Commercial Data)≤ 3.2 mV
Back of the hand protection (Key Commercial Data)guaranteed
Bending test rotation speed (Key Commercial Data)10 rpm
Result of voltage-drop test (Key Commercial Data)Test passed
Surge voltage test setpoint (Key Commercial Data)7.3 kV
Conductor cross section flexible max. (Dimensions)6 mm²
Conductor cross section flexible min. (Dimensions)0.5 mm²
Connection in acc. with standard (Connection data)IEC 60947-7-1
Result of surge voltage test (Key Commercial Data)Test passed
NF F16-101, NF F10-102 Class F (Key Commercial Data)2
NF F16-101, NF F10-102 Class I (Key Commercial Data)2
Result of tight fit on support (Key Commercial Data)Test passed
Short circuit stability result (Key Commercial Data)Test passed
Connection in acc. with standard (Key Commercial Data)IEC 60947-7-1
Oxygen index (DIN EN ISO 4589-2) (Key Commercial Data)>32 %
Flammability rating according to UL 94 (Connection data)V0
Shock protection test specification (Key Commercial Data)IEC 60529:2001-02
Conductor cross section tensile test (Key Commercial Data)10 mm²
Flame test method (DIN EN 60695-11-10) (Key Commercial Data)V0
Flammability rating according to UL 94 (Key Commercial Data)V0
Smoke gas toxicity NFPA 130 (SMP 800C) (Key Commercial Data)passed
2 conductors with same cross section, solid max. (Dimensions)10 mm²
2 conductors with same cross section, solid min. (Dimensions)0.5 mm²
2 conductors with same cross section, stranded max. (Dimensions)6 mm²
2 conductors with same cross section, stranded min. (Dimensions)0.5 mm²
Power frequency withstand voltage setpoint (Key Commercial Data)1.89 kV
Surface flammability NFPA 130 (ASTM E 162) (Key Commercial Data)passed
Bending test conductor cross section/weight (Key Commercial Data)0.5 mm² / 0.3 kg
Conductor cross section short circuit testing (Key Commercial Data)10 mm²
Static insulating material application in cold (Key Commercial Data)-60 °C
Behavior in fire for rail vehicles (DIN 5510-2) (Key Commercial Data)Test passed
Calorimetric heat release NFPA 130 (ASTM E 1354) (Key Commercial Data)27,5 MJ/kg
Result of power-frequency withstand voltage test (Key Commercial Data)Test passed
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Connection data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Connection data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Connection data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 (Connection data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Key Commercial Data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Key Commercial Data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 (Key Commercial Data)HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662) (Key Commercial Data)passed
Conductor cross section flexible, with ferrule with plastic sleeve max. (Dimensions)6 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min. (Dimensions)0.5 mm²
Relative insulation material temperature index (Elec., UL 746 B) (Key Commercial Data)130 °C
Conductor cross section flexible, with ferrule without plastic sleeve max. (Dimensions)10 mm²
Conductor cross section flexible, with ferrule without plastic sleeve min. (Dimensions)0.5 mm²
Proof of thermal characteristics (needle flame) effective duration (Key Commercial Data)30 s
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) (Key Commercial Data)125 °C
2 conductors with same cross section, stranded, ferrules without plastic sleeve, max. (Dimensions)4 mm²
2 conductors with same cross section, stranded, ferrules without plastic sleeve, min. (Dimensions)0.5 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. (Dimensions)6 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. (Dimensions)0.5 mm²
Result of the test for mechanical stability of terminal points (5 x conductor connection) (Key Commercial Data)Test passed

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top