| Parameter | Value |
|---|---|
| GTIN | 4017918309671 |
| Note | Made to Order (non-returnable) |
| Orderkey | 2979511 |
| Depth (Note) | 57.5 mm |
| Packing unit | 1 pc |
| Width (Note) | 130.5 mm |
| Height (Note) | 90 mm |
| Country of origin | DE (Germany) |
| Custom tariff number | 85364190 |
| Minimum order quantity | 10 pc |
| Connection name (General) | Controller level |
| Contact type (Input data) | Single contact, 2-PDT |
| Connection method (General) | D-SUB pin strip |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Contact material (Input data) | AgNi 0,15 + HTV (hard gold-plated) |
| Number of positions (General) | 25 |
| Mounting position (Output data) | any |
| Number of connections (General) | 1 |
| Degree of protection (Output data) | IP00 |
| Maximum inrush current (Input data) | 0.2 A |
| Weight per Piece (excluding packing) | 298.000 g |
| Mechanical service life (Output data) | 2x 107cycles |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Maximum switching voltage (Input data) | 24 V AC/DC |
| REACh SVHC (Standards and Regulations) | Lead 7439-92-1 |
| Limiting continuous current (Input data) | 0.5 A |
| Typical release time (Ambient conditions) | 10 ms |
| Connection in acc. with standard (General) | DIN 41652/IEC 60807-2 |
| Typical response time (Ambient conditions) | 9 ms |
| Ambient temperature (operation) (Dimensions) | -20 °C ... 50 °C |
| Insulation (Connection data for connection 2) | Functional insulation |
| Nominal input voltage UN (Ambient conditions) | 24 V DC |
| Utilization restriction (Key Commercial Data) | EMC: class A product, see manufacturer's declaration in the download area |
| Designation (Connection data for connection 2) | Air clearances and creepage distances |
| Typical input current at UN (Ambient conditions) | 21 mA |
| Connection name (Connection data for connection 1) | Field level |
| Interrupting rating (ohmic load) max. (Input data) | 5 W |
| Connection method (Connection data for connection 1) | Screw connection |
| Degree of pollution (Connection data for connection 2) | 2 |
| Rated surge voltage (Connection data for connection 2) | 0.6 kV (1.2/50 μs) |
| Overvoltage category (Connection data for connection 2) | II |
| Standards/regulations (Connection data for connection 2) | DIN EN 50178: 1998-04 |
| Input voltage range in reference to UN (Ambient conditions) | 0.8 ... 1.1 |
| Rated insulation voltage (Connection data for connection 2) | 63 V |
| Conductor cross section AWG (Connection data for connection 1) | 24 ... 12 |
| Conductor cross section solid (Connection data for connection 1) | 0.2 mm² ... 2.5 mm² |
| Conductor cross section flexible (Connection data for connection 1) | 0.2 mm² ... 2.5 mm² |