| Parameter | Value |
|---|---|
| GTIN | 4055626141442 |
| Note | Made to Order (non-returnable) |
| Orderkey | 2906944 |
| Depth (Note) | 66 mm |
| Packing unit | 1 pc |
| Width (Note) | 344 mm |
| Height (Note) | 126 mm |
| Country of origin | DE (Germany) |
| Custom tariff number | 85371098 |
| (Ambient conditions) | Reverse polarity protection |
| Connection name (General) | Controller level |
| Contact type (Input data) | 1 PDT |
| Connection method (General) | D-SUB pin strip |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Operating mode (Output data) | 100% operating factor |
| Contact material (Input data) | Ag alloy, hard gold-plated |
| No. of channels (Output data) | 16 |
| Number of positions (General) | 37 |
| Mounting position (Output data) | any |
| Number of connections (General) | 1 |
| (Connection data for connection 3) | TDIL11 (redundant) |
| Assembly instructions (Output data) | In rows with zero spacing |
| Min. switching current (Input data) | 1 mA (10 mA with damaged gold coating) |
| Weight per Piece (excluding packing) | 1,093.600 g |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Maximum switching voltage (Input data) | 36 V DC |
| Minimum switching voltage (Input data) | 100 mV (12 V DC with damaged gold coating) |
| REACh SVHC (Standards and Regulations) | Lead 7439-92-1 |
| Limiting continuous current (Input data) | 50 mA (500 mA with damaged gold coating) |
| Pitch (Connection data for connection 1) | 2.54 mm |
| Typical release time (Ambient conditions) | 7 ms |
| Degree of pollution (Supported controller) | 2 |
| Rated surge voltage (Supported controller) | 0.6 kV |
| Typical response time (Ambient conditions) | 5 ms |
| Overvoltage category (Supported controller) | II |
| Status display/channel (Ambient conditions) | Yellow LED |
| Ambient temperature (operation) (Dimensions) | -15 °C ... 50 °C |
| Standards/regulations (Supported controller) | DIN EN 50178 |
| Nominal input voltage UN (Ambient conditions) | 24 V DC |
| Utilization restriction (Key Commercial Data) | EMC: class A product, see manufacturer's declaration in the download area |
| Screw thread (Connection data for connection 2) | M3 |
| Typical input current at UN (Ambient conditions) | 6.5 mA |
| Protective circuit/component (Ambient conditions) | Fuse |
| Connection name (Connection data for connection 1) | Controller level |
| Connection name (Connection data for connection 2) | Field level |
| Interrupting rating (ohmic load) max. (Input data) | 1.2 W (at 24 V DC) |
| Stripping length (Connection data for connection 2) | 8 mm |
| Ambient temperature (storage/transport) (Dimensions) | -15 °C ... 50 °C |
| Connection method (Connection data for connection 1) | IDC/FLK pin strip |
| Connection method (Connection data for connection 2) | Screw connection with disconnect knife |
| Number of positions (Connection data for connection 1) | 50 |
| Corresponding control (Connection data for connection 3) | HONEYWELL Experion PKS C300/C-Series |
| Number of connections (Connection data for connection 1) | 1 |
| Corresponding I/O card (Connection data for connection 3) | TDIL01 (non-redundant) |
| Input voltage range in reference to UN (Ambient conditions) | 0.85 ... 1.1 |
| Conductor cross section AWG (Connection data for connection 2) | 24 ... 12 |
| Conductor cross section solid (Connection data for connection 2) | 0.2 mm² ... 4 mm² |
| Conductor cross section flexible (Connection data for connection 2) | 0.2 mm² ... 2.5 mm² |
Technical specifications and performance data
Installation and operation guide