| Parameter | Value |
|---|---|
| GTIN | 4017918995744 |
| Note | Made to Order (non-returnable) |
| Orderkey | 2305046 |
| Catalog page | Page 286 (NTK-2006) |
| Packing unit | 1 pc |
| Country of origin | DE (Germany) |
| Color (Output data) | green |
| Custom tariff number | 85364190 |
| Screw thread (General) | M3 |
| Connection name (General) | Field level |
| Stripping length (General) | 8 mm |
| Connection method (General) | Screw connection |
| Depth (Key Commercial Data) | 75 mm |
| Width (Key Commercial Data) | 181 mm |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Height (Key Commercial Data) | 126 mm |
| No. of channels (Output data) | 32 |
| Number of positions (General) | 6 |
| Mounting position (Output data) | any |
| Number of connections (General) | 103 |
| (Connection data for connection 2) | 0 mA ... 0.35 mA (In the event of a wire break) |
| Assembly instructions (Output data) | In rows with zero spacing |
| Weight per Piece (excluding packing) | 417.060 g |
| Conductor cross section AWG (General) | 24 ... 12 |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Maximum switching voltage (Input data) | 30 V DC |
| Operating voltage display (Input data) | Green LED |
| Conductor cross section solid (General) | 0.2 mm² ... 4 mm² |
| Corresponding control (Control circuit) | Emerson DeltaV |
| Type of protection (Ambient conditions) | Fuse |
| Corresponding I/O card (Control circuit) | VE4001S2T2B5 |
| Limiting continuous current (Input data) | 10 mA |
| Pitch (Connection data for connection 1) | 2.54 mm |
| Housing insulation material (Output data) | Polyamide PA non-reinforced |
| Conductor cross section flexible (General) | 0.2 mm² ... 2.5 mm² |
| Connection in acc. with standard (General) | IEC / EN |
| Degree of pollution (Supported controller) | 2 |
| Rated surge voltage (Supported controller) | 0.4 kV (basic insulation) |
| Overvoltage category (Supported controller) | I |
| Transmission frequency (Ambient conditions) | 350 Hz |
| Ambient temperature (operation) (Dimensions) | -20 °C ... 50 °C |
| Standards/regulations (Supported controller) | DIN EN 50178 |
| Nominal input voltage UN (Ambient conditions) | 24 V DC ±20 % |
| Operating voltage display (Ambient conditions) | Green LED |
| Typical input current at UN (Ambient conditions) | max. 320 mA |
| Protective circuit/component (Ambient conditions) | Fuse (400 mA) |
| Connection name (Connection data for connection 1) | Controller level |
| Switching point (Connection data for connection 2) | ≥ 2.1 mA (In conductive state) |
| Non-load voltage (Connection data for connection 2) | 8.2 V DC ±10 % |
| Ambient temperature (storage/transport) (Dimensions) | -20 °C ... 70 °C |
| Connection method (Connection data for connection 1) | IDC/FLK pin strip |
| Internal resistance (Connection data for connection 2) | approx. 1 kΩ |
| Number of positions (Connection data for connection 1) | 50 |
| Switching hysteresis (Connection data for connection 2) | approx. 0.2 mA |
| Number of connections (Connection data for connection 1) | 1 |
| Short-circuit current (Connection data for connection 2) | ≤ 10 mA |
| Error detection (line break / short-circuit) (Input data) | LED red |