| Parameter | Value |
|---|---|
| GTIN | 4055626892627 |
| Orderkey | 1089344 |
| (Drawings) | Do not use for isolation |
| Depth (Note) | 60.5 mm |
| Packing unit | 1 |
| Width (Note) | 217.5 mm |
| (Input data) | 1.7 A (at 50 °C, protected by fuse (2 AT)) |
| Height (Note) | 127.5 mm |
| Note (Drawings) | Do not connect adjacent channels to SELV/PELV and FELV. |
| ETIM 5.0 (eCl@ss) | EC002780 |
| ETIM 6.0 (eCl@ss) | EC002780 |
| ETIM 7.0 (eCl@ss) | EC002780 |
| (Connection data 3) | NFDV561 |
| Custom tariff number | 85364900 |
| Connection name (General) | Controller level |
| Contact type (Input data) | 1 N/O contact |
| Connection method (General) | Yokogawa KS-compatible |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Operating mode (Output data) | 100% operating factor |
| eCl@ss 8.0 (Classifications) | 27141152 |
| eCl@ss 9.0 (Classifications) | 27141152 |
| Contact material (Input data) | AgSnO |
| Number of positions (General) | 50 |
| Controller (Connection data 3) | YOKOGAWA CENTUM VP |
| Dimensional drawing (Drawings) | |
| Mounting position (Output data) | any |
| Number of connections (General) | 2 |
| Connection name (Connection data) | Field level |
| Degree of protection (Dimensions) | IP20 |
| Utilization restriction (Drawings) | EMC: class A product, see manufacturer's declaration in the download area |
| Assembly instructions (Output data) | In rows with zero spacing |
| Connection method (Connection data) | Screw connection |
| Connection name (Connection data 2) | Supply |
| Min. switching current (Input data) | 1 mA (24 V) |
| Connection method (Connection data 2) | Screw connection |
| Mechanical service life (Output data) | 2x 107cycles |
| Number of positions (Connection data) | 2 |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Maximum switching voltage (Input data) | 24 V DC |
| Minimum switching voltage (Input data) | 5 V (100 mA) |
| REACh SVHC (Standards and Regulations) | Lead 7439-92-1 |
| - suitable I/O card (Connection data 3) | ADV551 |
| Number of connections (Connection data) | 32 |
| Number of positions (Connection data 2) | 2 |
| Pollution degree (Supported controller) | 2 |
| Limiting continuous current (Input data) | 2 A (at 23 °C, protected by fuse (2 AT)) |
| Number of connections (Connection data 2) | 4 |
| Typical release time (Ambient conditions) | 6 ms |
| Rated surge voltage (Supported controller) | 0.5 kV (basic insulation) |
| Typical response time (Ambient conditions) | 5 ms |
| Overvoltage category (Supported controller) | II |
| Status display/channel (Ambient conditions) | green LED |
| Ambient temperature (operation) (Dimensions) | -20 °C ... 50 °C |
| Standards/regulations (Supported controller) | DIN EN 50178 |
| Conductor cross section AWG (Connection data) | 24 ... 12 |
| Nominal input voltage UN (Ambient conditions) | 24 V DC |
| Conductor cross section AWG (Connection data 2) | 24 ... 12 |
| Conductor cross section solid (Connection data) | 0.2 mm² ... 4 mm² |
| Rated insulation voltage (Supported controller) | 50 V AC |
| Typical input current at UN (Ambient conditions) | 7 mA |
| Conductor cross section solid (Connection data 2) | 0.2 mm² ... 4 mm² |
| Conductor cross section flexible (Connection data) | 0.2 mm² ... 2.5 mm² |
| Interrupting rating (ohmic load) max. (Input data) | 48 W |
| Ambient temperature (storage/transport) (Dimensions) | -20 °C ... 80 °C |
| Conductor cross section flexible (Connection data 2) | 0.2 mm² ... 2.5 mm² |
| Input voltage range in reference to UN (Ambient conditions) | 0.8 ... 1.2 |