ULSH201 - ULSH201 LS-H201 PANASONIC Sensor head, diffuse reflective, range 300mm, cable 2m
In Stock Hot Product

ULSH201

ULSH201 LS-H201 PANASONIC Sensor head, diffuse reflective, range 300mm, cable 2m

$0.00USD
4580 in stock
Key Specifications
Item:Specifications
Cable:0.09 mm22-core two parallel shielded cables, 2 m 6.562 ft long(Note:Cable cannot be extended.)
Weight:Net weight: 50 g approx.Gross weight: 80 g approx.
Details:Sensor heads(Coaxial reflective type)
Supplier Information
PANASONIC
PANASONIC
Products: 4316
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
ItemSpecifications
Cable0.09 mm22-core two parallel shielded cables, 2 m 6.562 ft long(Note:Cable cannot be extended.)
WeightNet weight: 50 g approx.Gross weight: 80 g approx.
DetailsSensor heads(Coaxial reflective type)
ProductAmplifier-separated Type Digital Laser Sensor
MaterialEnclosure: PBTIndicator cover: PolycarbonateBeam-emitting / receiving surfaces: Glass
AccessoryMS-LS-1 (Mounting bracket): 1pc.
Spot sizeApprox. dia. 2 mm dia. 0.079 in or less (at a distance from the sensor head of 300 mm 11.811 in)
ProtectionIP40 (IEC)
Part NumberLS-H201
Product nameAmplifier-separated Type Digital Laser Sensor LS-500
Product NumberLS-H201
Sensing objectOpaque, translucent, or transparent object(Note:Make sure to confirm detection with an actual sensor before use.)
Ambient humidity35 to 85 % RH, Storage: 35 to 85 % RH
Shock resistance98 m / s2acceleration (10 G approx.) in X, Y and Z directions three times each
Sensing range:HYPR750mm29.528 in(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Sensing range:U-LG600mm23.622 in(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Ambient illuminanceIncandescent light: 3,000 ℓx or less at the light-receiving face
Ambient temperature-10 to +55degrees + 14 to + 131 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -20 to +70degrees -4 to +158 degrees Fahrenheit
Operation indicatorOrange LED (lights up when the amplifier output is ON)
Vibration resistance10 to 500 Hz frequency, 1.5 mm double amplitude or maximum acceleration 98 m/s2in X, Y, and Z direction for 2 hours each.
Applicable amplifiersLS-501(P), LS-501(P)-C2(Note:When using the thru-beam typeLS-H101□orLS-H102□, do not set the receiving light sensitivity (gctL) of the applicableLS-500series amplifier to level 2 or less. This is because there is a possibility of sensing becoming unstable.)
Emitting element:TypeRed semiconductor laser diode
Insulation resistance20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
Regulatory complianceEMC Directive, RoHS Directive
Sensing range:STD mode300mm11.811 in(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Sensing range:FAST mode200mm7.874 in(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Sensing range:H-SP mode150mm5.906 in(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Sensing range:U-LG mode450mm17.717 in(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm3.937 × 3.937 in) as the object.)(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m0.033 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicableLS-500series amplifiers, leave an adequate safety margin when setting the threshold.)
Voltage withstandability1,000 V AC for one min. between all supply terminals connected together and enclosure
Emitting element:Laser classClass 1 [IEC / EN / JIS / GB / KS / FDA](Note:This product complies with the FDA regulations (FDA 21 CFR 1040.10 and 1040.11) in accordance with FDA Laser Notice No. 56, except for complying with IEC 60825-1 Ed. 3.
Emitting element:Max. output2mW
Emitting element:Peak emission wavelength660 nm 0.026 mil