Service time: Monday to Friday 9:00-18:00
ULS501P - ULS501P LS-501P PANASONIC Laser Amplifier (with display), connector type, 2 outputs PNP
In Stock Hot Product

ULS501P

ULS501P LS-501P PANASONIC Laser Amplifier (with display), connector type, 2 outputs PNP

$0.00USD
3330 in stock
Key Specifications
Item:Specifications
Cable:-
Weight:Net weight: 15 g approx.Gross weight: 55 g approx.
Details:Amplifiers(Connector type)
Supplier Information
PANASONIC
PANASONIC
Products: 4316
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
ItemSpecifications
Cable-
WeightNet weight: 15 g approx.Gross weight: 55 g approx.
DetailsAmplifiers(Connector type)
ProductAmplifier-separated Type Digital Laser Sensor
MaterialEnclosure: PolycarbonateCover: PolycarbonateSwitch: Polyacetal
AccessoryFX-MB1 (Amplifier protective seal): 1 set
ProtectionIP40(IEC)
Part NumberLS-501P
Product nameAmplifier-separated Type Digital Laser Sensor LS-500
Response timeH-SP: 60 micro s or less, FAST: 150 micro s or less, STD: 250 micro s or less, LONG: 500 micro s or less, U-LG: 5 ms or less, HYPR: 24 ms or less selectable
External inputPNP non-contact input- Signal condition High: +4 Vto+V DC(sink current 3.0 mA or less), Low: 0 to +0.6 V DC or open- Input impedance: 10 kOhm approx.(Note:Select either sensing output 2 or external input.)
Product NumberLS-501P
Supply voltage12 to 24 V DC +10-15% Ripple P-P 10 % or less
Timer functionOFF-delay timer, ON-delay timer, ONE-SHOT timer, ON / OFF-delay timer, ON-delay / ONE-SHOT timer,switchable either effective of ineffective, with variable timer periodOFF-delay timer, ON-delay timer, ONE-SHOT timer,switchable either effective of ineffective, with variable timer period
Cable extensionExtension up to total 100 m 328.084 ft is possible with 0.3mm2, or more, cable.
Digital display8-digit 7-segment digital display (4-digit green LED + 4-digit red LED), MODE indicator (Yellow LED): L/D, CUST, PRO
Ambient humidity35 to 85 % RH, Storage: 35 to 85 % RH
Shock resistance98 m/s2acceleration (10 G approx.) in X, Y and Z directions for five times each
Logical operationBetween sensing output 1 and calculation target: Disabled / and / or / xor, selectableCalculation target: Sensing output 2 / adjacent upstream amplifier (sensing output 1) / external input, selectable
Power consumptionNormal operation: 1,200 mW or less (Current consumption 50 mA or less at 24 V supply voltage)ECO mode: 980 mW or less (Current consumption 40 mA or less at 24 V supply voltage)
Ambient temperature-10 to +55degrees + 14 to 131 degrees Fahrenheit (If 4 to 7 units are mounted close together, -10 to +50 degrees +14 to +122 degrees Fahrenheit ; if 8 to 16 units are mounted close together, -10 to +45 degrees +14 to +113 degrees Fahrenheit )(No dew condensation or icing allowed), Storage: -20 to +70 degrees -4 to +158 degrees Fahrenheit
Operation indicatorOrange LED (lights up when sensing output 1 or sensing output 2 is ON)
Sensitivity setting2-level teaching / limit teaching / full auto teaching / manual adjustment
Timer function:TimeTimer range '' ms'': 0.5 ms approx., 1 to 9,999 ms approx., in approx. 1 ms intervalsTimer range '' sec'': 0.5 sec. approx., 1 to 32 sec. approx., in approx. 1 sec. intervalsTimer range '' 1/10 ms'': 0.05 ms approx., 0.1 to 999.9 ms approx., in approx. 0.1 ms intervals, Set separately for each output.
Vibration resistance10 to 150 Hz frequency, 1.5 mm double amplitude or maximum acceleration 98 m/s2in X, Y, and Z direction for 2 hours each.
Insulation resistance20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
Regulatory complianceEMC Directive, RoHS Directive
Monitor current output-
External input functionLaser emission halt / teaching (full-auto teaching, limit teaching, 2 point teaching) / logic operation setting / copy lock /display adjustment / data bank load / data bank save, selectable
Output select indicatorYellow LED (lights up when output is selected)
Laser emission indicatorGreen LED (lights up during laser emission)
Voltage withstandability1,000 V AC for one min. between all supply terminals connected together and enclosure
Incident light indication rangeH-SP/FAST/STD: 0 to 4,000LONG/U-LG/HYPR: 0 to 9,999
Sensing outputs (Sensing output 1, 2)PNP open-collector transistor・Maximum source current: 50 mA (Note:25 mA if 5 or more amplifier are connected in cascade (excluding cable extension).)・Applied voltage: 30 V DC or less (between output and +V)・Residual voltage: 2 V or less (at max. source current)(Note:Select either sensing output 2 or external input as the connector type.)
Sensing output setting:Sensing output 1Normal mode, differential mode, hysteresis mode, window comparator mode, selectable
Sensing output setting:Sensing output 2Normal mode, differential mode, hysteresis mode, self-diagnostic output mode, selectable(Note:Select either sensing output 2 or external input.)
Automatic interference prevention functionIncorporated(Note:Number of units that can be mounted close together: 0 for H-SP; 2 for FAST; 4 for STD, LONG, U-LG, or HYPR)
Sensing outputs (Sensing output 1, 2):Output operationSelectable either Light-ON or Dark-ON
Sensing outputs (Sensing output 1, 2):Short-circuit protectionIncorporated

Product Description

LS500. Laser Amplifier (with display), connector, 2 PNP outputs
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top