| Parameter | Value |
|---|---|
| Item | Specifications |
| Cable | 0.15 mm25-core cabtyre cable, 2 m6.562 ftlong |
| Weight | Net weight: 65 g approxGross weight: 75 g approx |
| Details | Amplifier (Cable type) |
| Product | Digital Laser Sensor |
| Material | Enclosure: Heat-resistant ABSTransparent cover: PolycarbonatePush button switch: AcrylicJog switch: ABS |
| Part Number | LS-401-C2 |
| Product name | Digital Laser Sensor LS-400 |
| Response time | 80 micro s or less (H-SP), 150 micro s or less (FAST), 500 micro s or less (STD), 4 ms or less (U-LG) selectable with jog switch |
| MODE indicator | RUN: Green LEDTEACH, L/D, TIMER, CUST, PRO: Yellow LED |
| Product Number | LS-401-C2 |
| Supply voltage | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Timer function | Incorporated with variable ON-delay / OFF-delay / ONE SHOT timer, switchable either effective or ineffective. |
| Cable extension | Extension up to total 100 m328.084 ftis possible with 0.3 mm2, or more, cable. |
| Digital display | 4 digit (green) + 4 digit (red) LED display |
| Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Select indicator | Yellow LED(lights up when either output 1 or output 2 is selected) |
| Shock resistance | 98 m/s2acceleration (10 G approx.) in X, Y and Z directions five times each |
| Ambient temperature | -10 to +55 ℃+14 to +131 ℉(If 4 to 7 units are mounted close together: -10 to +50 ℃+14 to +122 ℉, if 8 to 16 units are mounted close together: -10 to +45 ℃+14 to +113 ℉)(No dew condensation or icing allowed),Storage: -20 to +70 ℃-4 to +158 ℉ |
| Current consumption | Normal operation: 950 mW or less (Current consumption 40 mA or less at 24 V supply voltage)ECO mode: 780 mW or less (Current consumption 33 mA or less at 24 V supply voltage) |
| Operation indicator | Orange LED (lights up when output 1 and output 2 are ON) |
| Sensitivity setting | Normal mode: 2-level teaching / Limit teaching / Full-auto teaching / Manual adjustmentWindow comparator mode: Teaching (1-level, 2-level, 3-level) / Manual adjustmentHysteresis mode: Teaching (1-level, 2-level, 3-level) / Manual adjustmentDifferential mode: 5-level settings |
| Timer function:Time | 1 to 9,999 ms |
| Vibration resistance | 10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude in X, Y and Z directions for two hours each |
| Insulation resistance | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Laser emission indicator | Green LED (lights up during laser emission) |
| Voltage withstandability | 1,000 V AC for one min.between all supply terminals connected together and enclosure |
| Outputs(Output 1, Output 2) | NPN open-collector transistor- Maximum sink current: 100 mA (Note)- Applied voltage: 30 V DC or less (between output and 0 V)- Residual voltage: 1.5 V or less [at 100 mA (Note) sink current](Note) 50 mA if 5 to 8 connector type amplifiers are connected in cascade , and 25 mA if 9 to 16 connector type amplifiers are connected in cascade. |
| Fine sensitivity adjustment function | Incorporated |
| Automatic Interference prevention function | Incorporated[Up to four sets of sensor heads can be mounted close together. (However, disabled when in H-SP mode)] |
| Outputs(Output 1, Output 2):Output operation | Selectable either Light-ON or Dark-ON, with jog switch |
| Outputs(Output 1, Output 2):Short-circuit protection | Incorporated |
| External input(Laser emission halt Full-auto teaching / Limit teaching) | NPN non-contact input- Signal conditionHigh: +5 V to +V DC or open, Low: 0 to +2 V DC (source current 0.5 mA or less)- Input impedance: 10 kOhm approx. |