Service time: Monday to Friday 9:00-18:00
UKH 240 - UKH 240 3010217 PHOENIX CONTACT High-current terminal block
In Stock Hot Product

UKH 240

UKH 240 3010217 PHOENIX CONTACT High-current terminal block

$44.76USD
257 in stock
Key Specifications
:1201659 E/AL-NS 32
Note:For a reliable contact of multi stranded conductors it is recommended to untwist multi stranded conductors.
Color:gray (RAL 7042)
Depth:123.6 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
1201659 E/AL-NS 32
NoteFor a reliable contact of multi stranded conductors it is recommended to untwist multi stranded conductors.
Colorgray (RAL 7042)
Depth123.6 mm
Width36 mm
Height100 mm
ResultTest passed
output(Permanent)
SpectrumService life test category 2, bogie-mounted
ASD level6.12 (m/s²)²/Hz
Frequencyf1= 5 Hz to f2= 250 Hz
Potentials1
Bridge data270 A / 240 mm²
Pulse shapeHalf-sine
Revolutions135
Acceleration3.12g
Product typeHigh current terminal block
Screw threadM10
Torque range25 Nm ... 30 Nm
Mounting typeNS 35/15
Rated current350 A
Rated voltage1100 V
SpecificationDIN EN 50155 (VDE 0115-200):2022-06
Identification II 2 GD Ex eb IIC Gb
Number of rows1
Rotation speed10 (+/- 2) rpm
Shock duration30 ms
Depth on NS 32129 mm
List of bridgesInsertion bridge / EB 2-36/UKH / 0201401
Nominal current415 A
Nominal voltage1000 V
Open side panelNo
Test directionsX-, Y- and Z-axis
Article revision11
Stripping length40 mm
Time of exposure30 s
Cross section AWG3/0 ... 250 kcmil (converted acc. to IEC)
Tightening torque25 ... 30 Nm
Contact resistance0.03 mΩ
Depth on NS 35/15131.5 mm
Degree of pollution3
Dimensional drawing
Insulating materialPA
Rated surge voltage8 kV
Maximum load current415 A (with 240 mm² conductor cross section)
Overvoltage categoryIII
Nominal cross section240 mm²
Number of connections2
Test voltage setpoint2.2 kV
Test duration per axis5 h
Connection capacity AWG2/0 ... 500 kcmil
DIN rail/fixing supportNS 32/NS 35
Ex temperature increase40 K (389 A/240 mm²)
Rated cross section AWG500 kcmil
Ex-certified accessories1201947 VDE-ISS 8
Rated insulation voltage1000 V
Connection capacity rigid70 mm² ... 240 mm²
Insulating material groupI
Internal cylindrical gageB15
Operating temperature range-60 °C ... 110 °C
Connection capacity flexible70 mm² ... 240 mm²
Conductor cross section rigid70 mm² ... 240 mm²
Ambient temperature (assembly)-5 °C ... 70 °C
Conductor cross section/weight70 mm²/10.4 kg
Number of shocks per direction3
Ambient temperature (actuation)-5 °C ... 70 °C
Ambient temperature (operation)-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Number of connections per level2
Conductor cross section flexible70 mm² ... 240 mm²
Connection in acc. with standardIEC 60947-7-1
Permissible humidity (operation)20 % ... 90 %
at bridging with insertion bridge690 V
Short-time withstand current 240 mm²28.8 kA
Flammability rating according to UL 94V0
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C)
Conductor cross section, flexible [AWG]3/0 ... 350 kcmil (converted acc. to IEC)
Permissible humidity (storage/transport)30 % ... 70 %
Cross-section with insertion bridge, rigid240 mm²
Surface flammability NFPA 130 (ASTM E 162)passed
2 conductors with same cross section, solid35 mm² ... 95 mm²
Cross-section with insertion bridge, flexible185 mm²
2 conductors with same cross section, flexible50 mm² ... 95 mm²
2 conductors with same cross section, stranded50 mm² ... 95 mm²
Static insulating material application in cold-60 °C
Maximum power dissipation for nominal condition13.78 W
2 conductors with the same cross-section AWG rigid2 ... 3/0
2 conductors with the same cross-section AWG flexible1/0 ... 3/0
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Flexible conductor cross section (ferrule with plastic sleeve)70 mm² ... 185 mm²
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Conductor cross-section flexible (ferrule without plastic sleeve)70 mm² ... 185 mm²
2 conductors with same cross section, flexible, with ferrule without plastic sleeve35 mm² ... 50 mm²

Product Description

Current terminal, nominal voltage: 1000 V, nominal current: 415 A, number of connections: 2, connection type: Screw connection, Sizing cross-section: 240 mm², cross-section: 70 mm² - 240 mm², mounting
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top