Key Specifications
GTIN:4017918282196
Orderkey:3004168
Packing unit:50 pc
Width (General):8.2 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4017918282196
Orderkey3004168
Packing unit50 pc
Width (General)8.2 mm
Length (General)72.5 mm
Country of originTR (Turkey)
(Connection data)IEC 60947-7-3
Custom tariff number85369095
(Key Commercial Data)For lever marking, please use marking material with 6.2 mm pitch.
Height NS 32 (General)61.5 mm
Height NS 35/15 (General)64 mm
Screw thread (Dimensions)M3
Height NS 35/7,5 (General)56.5 mm
Note (Key Commercial Data)For terminal marking, please use marking material with 8.2 mm pitch.
Color (Key Commercial Data)orange
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Stripping length (Dimensions)8 mm
Connection method (Dimensions)Screw connection
Tightening torque max (Dimensions)0.8 Nm
Tightening torque, min (Dimensions)0.6 Nm
Weight per Piece (excluding packing)23.620 g
Open side panel (Key Commercial Data)No
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Internal cylindrical gage (Dimensions)A4
Number of levels (Key Commercial Data)1
REACh SVHC (Standards and Regulations)Lead 7439-92-1
Nominal current IN (Key Commercial Data)6.3 A
Nominal voltage UN (Key Commercial Data)500 V (As a fuse terminal block)
Degree of pollution (Key Commercial Data)3
Insulating material (Key Commercial Data)PA
Rated surge voltage (Key Commercial Data)6 kV
Maximum load current (Key Commercial Data)6.3 A
Overvoltage category (Key Commercial Data)III
Nominal cross section (Key Commercial Data)4 mm²
Number of connections (Key Commercial Data)2
Conductor cross section AWG max. (Dimensions)12
Conductor cross section AWG min. (Dimensions)24
Conductor cross section solid max. (Dimensions)4 mm²
Conductor cross section solid min. (Dimensions)0.2 mm²
Insulating material group (Key Commercial Data)I
Conductor cross section flexible max. (Dimensions)4 mm²
Conductor cross section flexible min. (Dimensions)0.2 mm²
Connection in acc. with standard (Connection data)CSA
NF F16-101, NF F10-102 Class F (Key Commercial Data)2
NF F16-101, NF F10-102 Class I (Key Commercial Data)2
Connection in acc. with standard (Key Commercial Data)IEC 60947-7-3
Oxygen index (DIN EN ISO 4589-2) (Key Commercial Data)>32 %
Flammability rating according to UL 94 (Connection data)V2
Cross section with insertion bridge, solid max. (Dimensions)4 mm²
Flame test method (DIN EN 60695-11-10) (Key Commercial Data)V0
Flammability rating according to UL 94 (Key Commercial Data)V2
Smoke gas toxicity NFPA 130 (SMP 800C) (Key Commercial Data)passed
2 conductors with same cross section, solid max. (Dimensions)1.5 mm²
2 conductors with same cross section, solid min. (Dimensions)0.2 mm²
Cross section with insertion bridge, stranded max. (Dimensions)4 mm²
2 conductors with same cross section, stranded max. (Dimensions)1.5 mm²
2 conductors with same cross section, stranded min. (Dimensions)0.2 mm²
Surface flammability NFPA 130 (ASTM E 162) (Key Commercial Data)passed
Static insulating material application in cold (Key Commercial Data)-60 °C
Behavior in fire for rail vehicles (DIN 5510-2) (Key Commercial Data)Test passed
Maximum power dissipation for nominal condition (Key Commercial Data)1.02 W
Calorimetric heat release NFPA 130 (ASTM E 1354) (Key Commercial Data)28 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Connection data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Connection data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Connection data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 (Connection data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Key Commercial Data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Key Commercial Data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Key Commercial Data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 (Key Commercial Data)HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662) (Key Commercial Data)passed
Conductor cross section flexible, with ferrule with plastic sleeve max. (Dimensions)4 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min. (Dimensions)0.25 mm²
Relative insulation material temperature index (Elec., UL 746 B) (Key Commercial Data)130 °C
Conductor cross section flexible, with ferrule without plastic sleeve max. (Dimensions)4 mm²
Conductor cross section flexible, with ferrule without plastic sleeve min. (Dimensions)0.25 mm²
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) (Key Commercial Data)130 °C
2 conductors with same cross section, stranded, ferrules without plastic sleeve, max. (Dimensions)1.5 mm²
2 conductors with same cross section, stranded, ferrules without plastic sleeve, min. (Dimensions)0.25 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. (Dimensions)1.5 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. (Dimensions)0.5 mm²

Product Description

Borne interrupts. for circ. Measurement, For terminal marking use the marking material with 8.2 mm division, nominal voltage: 800 V, nominal current: 6.3 A, connection type: Screw connection, Dimensio
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top