| Parameter | Value |
|---|---|
| 1205079 SZS 1,0X6,5 VDE | |
| Color | blue (RAL 5015) |
| Width | 15.1 mm |
| Height | 50 mm |
| output | (Permanent) |
| Potentials | 1 |
| Bridge data | 118.5 A / 35 mm² |
| Product type | Feed-through terminal block |
| Screw thread | M6 |
| Torque range | 3.2 Nm ... 3.7 Nm |
| Mounting type | NS 35/7,5 |
| Rated current | 118.5 A |
| Rated voltage | 690 V |
| Identification | II 2 GD Ex eb IIC Gb |
| Number of rows | 1 |
| Depth on NS 32 | 67 mm |
| List of bridges | Fixed bridge / FBI 2-15 / 0201333 |
| Nominal current | 125 A |
| Nominal voltage | 1000 V |
| Open side panel | No |
| Article revision | 11 |
| Stripping length | 16 mm |
| Cross section AWG | 18 ... 2 (converted acc. to IEC) |
| Tightening torque | 3.2 ... 3.7 Nm |
| Contact resistance | 0.08 mΩ |
| Depth on NS 35/15 | 69.5 mm |
| Degree of pollution | 3 |
| Depth on NS 35/7,5 | 62 mm |
| Insulating material | PA |
| Rated surge voltage | 8 kV |
| Maximum load current | 150 A (with 50 mm² conductor cross section) |
| Overvoltage category | III |
| Nominal cross section | 35 mm² |
| Number of connections | 2 |
| Connection capacity AWG | 18 ... 1/0 |
| Ex temperature increase | 40 K (130.5 A / 35 mm²) |
| Rated cross section AWG | 2 |
| Ex-certified accessories | 3008096 TP-UK 35 |
| Rated insulation voltage | 630 V |
| for bridging with bridge | 690 V |
| Connection capacity rigid | 0.75 mm² ... 50 mm² |
| Insulating material group | I |
| Internal cylindrical gage | B9 |
| Operating temperature range | -60 °C ... 110 °C |
| Connection capacity flexible | 0.75 mm² ... 35 mm² |
| Conductor cross section rigid | 0.75 mm² ... 50 mm² |
| Ambient temperature (assembly) | -5 °C ... 70 °C |
| Ambient temperature (actuation) | -5 °C ... 70 °C |
| Ambient temperature (operation) | -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.) |
| Number of connections per level | 2 |
| Conductor cross section flexible | 0.75 mm² ... 35 mm² |
| Connection in acc. with standard | IEC 60947-7-1 |
| Permissible humidity (operation) | 20 % ... 90 % |
| at bridging with insertion bridge | 690 V |
| Flammability rating according to UL 94 | V0 |
| Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C) |
| Conductor cross section, flexible [AWG] | 18 ... 2 (converted acc. to IEC) |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
| Surface flammability NFPA 130 (ASTM E 162) | passed |
| 2 conductors with same cross section, solid | 0.75 mm² ... 16 mm² |
| 2 conductors with same cross section, flexible | 0.75 mm² ... 10 mm² |
| 2 conductors with same cross section, stranded | 0.75 mm² ... 10 mm² |
| Static insulating material application in cold | -60 °C |
| Maximum power dissipation for nominal condition | 4.06 W |
| Calorimetric heat release NFPA 130 (ASTM E 1354) | 27,5 MJ/kg |
| 2 conductors with the same cross-section AWG rigid | 18 ... 6 |
| 2 conductors with the same cross-section AWG flexible | 18 ... 8 |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
| Flexible conductor cross section (ferrule with plastic sleeve) | 0.75 mm² ... 35 mm² |
| Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
| Conductor cross-section flexible (ferrule without plastic sleeve) | 0.75 mm² ... 35 mm² |
| Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) | 125 °C |
| 2 conductors with same cross section, flexible, with ferrule without plastic sleeve | 0.75 mm² ... 10 mm² |
| 2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve | 0.75 mm² ... 6 mm² |
Technical specifications and performance data
Installation and operation guide